• 제목/요약/키워드: Consecutive process

검색결과 308건 처리시간 0.028초

가변 샘플링 간격(VSI)을 갖는 적응형 이동평균 (A-MA) 관리도 (An Adaptive Moving Average (A-MA) Control Chart with Variable Sampling Intervals (VSI))

  • 임태진
    • 대한산업공학회지
    • /
    • 제33권4호
    • /
    • pp.457-468
    • /
    • 2007
  • This paper proposes an adaptive moving average (A-MA) control chart with variable sampling intervals (VSI) for detecting shifts in the process mean. The basic idea of the VSI A-MA chart is to adjust sampling intervals as well as to accumulate previous samples selectively in order to increase the sensitivity. The VSI A-MA chart employs a threshold limit to determine whether or not to increase sampling rate as well as to accumulate previous samples. If a standardized control statistic falls outside the threshold limit, the next sample is taken with higher sampling rate and is accumulated to calculate the next control statistic. If the control statistic falls within the threshold limit, the next sample is taken with lower sampling rate and only the sample is used to get the control statistic. The VSI A-MA chart produces an 'out-of-control' signal either when any control statistic falls outside the control limit or when L-consecutive control statistics fall outside the threshold limit. The control length L is introduced to prevent small mean shifts from being undetected for a long period. A Markov chain model is employed to investigate the VSI A-MA sampling process. Formulae related to the steady state average time-to signal (ATS) for an in-control state and out-of-control state are derived in closed forms. A statistical design procedure for the VSI A-MA chart is proposed. Comparative studies show that the proposed VSI A-MA chart is uniformly superior to the adaptive Cumulative sum (CUSUM) chart and to the Exponentially Weighted Moving Average (EWMA) chart, and is comparable to the variable sampling size (VSS) VSI EWMA chart with respect to the ATS performance.

가변 샘플링 간격(VSI)을 갖는 선택적 누적합 (S-CUSUM) 관리도 (A Selectively Cumulative Sum (S-CUSUM) Control Chart with Variable Sampling Intervals (VSI))

  • 임태진
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2006년도 추계학술대회
    • /
    • pp.560-570
    • /
    • 2006
  • This paper proposes a selectively cumulative sum (S-CUSUM) control chart with variable sampling intervals (VSI) for detecting shifts in the process mean. The basic idea of the VSI S-CUSUM chart is to adjust sampling intervals and to accumulate previous samples selectively in order to increase the sensitivity. The VSI S-CUSUM chart employs a threshold limit to determine whether to increase sampling rate as well as to accumulate previous samples or not. If a standardized control statistic falls outside the threshold limit, the next sample is taken with higher sampling rate and is accumulated to calculate the next control statistic. If the control statistic falls within the threshold limit, the next sample is taken with lower sampling rate and only the sample is used to get the control statistic. The VSI S-CUSUM chart produces an 'out-of-control' signal either when any control statistic falls outside the control limit or when L-consecutive control statistics fall outside the threshold limit. The number L is a decision variable and is called a 'control length'. A Markov chain model is employed to describe the VSI S-CUSUM sampling process. Some useful formulae related to the steady state average time-to signal (ATS) for an in-control state and out-of-control state are derived in closed forms. A statistical design procedure for the VSI S-CUSUM chart is proposed. Comparative studies show that the proposed VSI S-CUSUM chart is uniformly superior to the VSI CUSUM chart or to the Exponentially Weighted Moving Average (EWMA) chart with respect to the ATS performance.

  • PDF

Evolutionary Data Granulation 기반으로한 퍼지 집합 다항식 뉴럴 네트워크에 관한 연구 (A Study on Fuzzy Set-based Polynomial Neural Networks Based on Evolutionary Data Granulation)

  • 노석범;안태천;오성권
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 추계학술대회 학술발표 논문집 제14권 제2호
    • /
    • pp.433-436
    • /
    • 2004
  • In this paper, we introduce a new Fuzzy Polynomial Neural Networks (FPNNS)-like structure whose neuron is based on the Fuzzy Set-based Fuzzy Inference System (FS-FIS) and is different from that of FPNNS based on the Fuzzy relation-based Fuzzy Inference System (FR-FIS) and discuss the ability of the new FPNNS-like structure named Fuzzy Set-based Polynomial Neural Networks (FSPNN). The premise parts of their fuzzy rules are not identical, while the consequent parts of the both Networks (such as FPNN and FSPNN) are identical. This difference results from the angle of a viewpoint of partition of input space of system. In other word, from a point of view of FS-FIS, the input variables are mutually independent under input space of system, while from a viewpoint of FR-FIS they are related each other. The proposed design procedure for networks architecture involves the selection of appropriate nodes with specific local characteristics such as the number of input variables, the order of the polynomial that is constant, linear, quadratic, or modified quadratic functions being viewed as the consequent part of fuzzy rules, and a collection of the specific subset of input variables. On the parameter optimization phase, we adopt Information Granulation (IC) based on HCM clustering algorithm and a standard least square method-based learning. Through the consecutive process of such structural and parametric optimization, an optimized and flexible fuzzy neural network is generated in a dynamic fashion. To evaluate the performance of the genetically optimized FSPNN (gFSPNN), the model is experimented with using the time series dataset of gas furnace process.

  • PDF

특징 점 기반의 ICP 알고리즘을 이용한 2차원 격자지도 보정 (2D Grid Map Compensation Using ICP Algorithm based on Feature Points)

  • 황요섭;이동주;유호윤;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제21권10호
    • /
    • pp.965-971
    • /
    • 2015
  • This paper suggests a feature point-based Iterative Closest Point (ICP) algorithm to compensate for the disparity error in building a two-dimensional map. The ICP algorithm is a typical algorithm for matching a common object in two different images. In the process of building a two-dimensional map using the laser scanner data, warping and distortions exist in the map because of the disparity between the two sensor values. The ICP algorithm has been utilized to reduce the disparity error in matching the scanned line data. For this matching process in the conventional ICP algorithm, pre-known reference data are required. Since the proposed algorithm extracts characteristic points from laser-scanned data, reference data are not required for the matching. The laser scanner starts from the right side of the mobile robot and ends at the left side, which causes disparity in the scanned line data. By finding the matching points between two consecutive frame images, the motion vector of the mobile robot can be obtained. Therefore, the disparity error can be minimized by compensating for the motion vector caused by the mobile robot motion. The validity of the proposed algorithm has been verified by comparing the proposed algorithm in terms of map-building accuracy to conventional ICP algorithm real experiments.

Quantitative Analysis of Developmental Process of Cranial Suture in Korean Infants

  • Sim, Sook-Young;Yoon, Soo-Han;Kim, Sun-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권1호
    • /
    • pp.31-36
    • /
    • 2012
  • Objective : The purpose of this study was to elucidate the anatomical development of physiologic suture closure processes in infants using three dimensional reconstructed computed tomography (CT). Methods : A consecutive series of 243 infants under 12 months of age who underwent three dimensional CT were included in this study. Four major cranial sutures (sagittal, coronal, lambdoidal and metopic suture) were classified into four suture closure grades (grade 0=no closure along the whole length, grade 1=partial or intermittent closure, grade 2=complete closure with visible suture line, grade 3=complete fusion (ossification) without visible suture line), and measured for its closure degree (suture closure rates; defined as percentage of the length of closed suture line divided by the total length of suture line). Results : Suture closure grade under 12 months of age comprised of grade 0 (n=195, 80.2%), grade 1 (n=24, 9.9%) and grade 2 (n=24, 9.9%) in sagittal sutures, whereas in metopic sutures they were grade 0 (n=61, 25.1%), grade 1 (n=167, 68.7%), grade 2 (n=6, 24%) and grade 3 (n=9, 3.7%). Mean suture closure rates under 12 months of age was 58.8% in metopic sutures, followed by coronal (right : 43.8%, left : 41.1%), lambdoidal (right : 27.2%, left : 25.6%) and sagittal sutures (15.6%), respectively. Conclusion : These quantitative descriptions of cranial suture closure may help understand the process involved in the cranial development of Korean infants.

Anti-ulcerogenic activity of virgin coconut oil contribute to the stomach health of humankind

  • Selverajah, Malarvili;Zakaria, Zainul Amiruddin;Long, Kamariah;Ahmad, Zuraini;Yaacob, Azhar;Somchit, Muhammad Nazrul
    • 셀메드
    • /
    • 제6권2호
    • /
    • pp.11.1-11.7
    • /
    • 2016
  • The aimed of the presence study was to determine the antiulcer potential of virgin coconut oil (VCO), either extracted by wet process (VCOA) or fermentation process (VCOB), and to compare their effectiveness against the copra oil (CO) using the HCl/ethanol-induced gastric ulcer model. Earlier, the oils underwent chemical analysis to determine the free fatty acids composition, physicochemical properties and anti-oxidant capability. In the antiulcer study, rats (n=6) were pre-treated orally for 7 consecutive days with distilled water (vehicle), 100 mg/kg ranitidine (positive group) or the respective oils (10, 50, and 100% concentration). One hour after the last test solutions administration on Day 7th, the animals were subjected to the gastric ulcer assay. Macroscopic and microscopic analyses were performed on the collected rat's stomachs. From the results obtained, the chemical analysis revealed i) the presence of high content of lauric acid followed by myristic acid and palmitic acid in all oils and; ii) the significant (*p< 0.05) different in anisidine- and peroxide-value, percentage of free fatty acid, total phenolic content and total antioxidant activity among the oils. The animal study demonstrated that all oil possess significant (*p< 0.05) antiulcer activity with VCOB being the most effective oil followed by VCOA and CO. The macroscopic observations were supported by the microscopic findings. Interestingly, all oils were more effective than 100 mg/kg ranitidine (reference drug). In conclusion, coconut oils exert remarkable antiulcer activity depending on their methods of extraction, possibly via the modulation of its antioxidant and anti-inflammatory activity.

카메라 움직임 추정 및 패치 기반 디컨볼루션을 이용한 동영상의 번짐 현상 제거 방법 (Video Deblurring using Camera Motion Estimation and Patch-wise Deconvolution)

  • 정우진;박진욱;이종민;송태언;최원주;문영식
    • 전자공학회논문지
    • /
    • 제51권12호
    • /
    • pp.130-139
    • /
    • 2014
  • 동영상 촬영 시 급격한 카메라의 흔들림은 의도하지 않은 번짐 현상을 발생시켜 동영상의 품질을 낮추는 원인이 된다. 따라서 본 논문에서는 동영상의 품질을 높이기 위해 동영상에서 카메라 흔들림으로 인해 발생한 번짐 현상을 제거하는 방법을 제안한다. 제안하는 방법은 매 프레임 별로 이루어진다. 각 프레임마다 이전 프레임과 현재 프레임, 다음 프레임을 이용하여 카메라 움직임을 계산한다. 그리고 카메라의 움직임을 바탕으로 점 확산 함수를 계산하고 프레임을 패치 단위로 쪼개어 패치별 번짐 현상을 제거한다. 이때 품질을 높이기 위하여 번짐 영상으로부터 외곽선을 예측하는 방법을 사용한다. 번짐 현상이 제거된 패치는 다시 하나의 프레임으로 합한다. 실험 결과를 통해 제안하는 방법이 동영상에서의 카메라 흔들림으로 인한 번짐 현상을 효과적으로 제거함을 확인하였다.

햅틱 인터페이스를 이용한 가상 조각 시스템 (A Virtual Sculpting System using Haptic Interface)

  • 김래현;박세형
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제31권12호
    • /
    • pp.682-691
    • /
    • 2004
  • 본 논문에서는 햅틱 인터페이스를 통해 실제 찰흙을 만지는 것처럼 자연스럽게 가상 모델의 일부를 덧붙이거나 제거하여 원하는 모양을 만드는 햅틱 가상 조각 시스템을 소개하고자 한다. 햅틱 렌더링과 햅틱 툴에 의한 가상 모델의 변형은 볼륨 간접 표면 법을 기반으로 이루어진다. 본 시스템에서는 기존의 불륨 데이타 기반의 햅틱 조각 시스템이 갖는 문제점들을 개선하고 빠르고 안정된 알고리즘을 제안하였다. 먼저 가상의 물체를 조각하는 동안 빠른 햅틱 응답 속도(1 KHz)에 비해 훨씬 느린 비쥬얼 프로세싱(~30 Hz)의 속도 차이로 인해 발생되는 문제를 극복하기 위해 조각과정의 연속적인 두 모델의 중간 표면들을 생성하여 부드러운 햅틱 렌더링을 구현하였다. 조각 툴에 의해 변형되는 불륨 간접 표면은 비쥬얼 디스플레이를 위해 메쉬 모델로 컨버전 되는데 이때 메쉬 모델은 표면의 복잡도를 반영하여 적은 폴리곤으로 복잡한 모양을 보여줄 수 있는 비 군일 메쉬 생성 기법을 사용하였다. 실시간 조각과정에서 가상 물체의 다양한 비쥬얼 효과를 위해 메쉬 기반의 솔리드 덱스쳐링, 페인팅, 그리고 모델의 양각/음각기법도 구현하였다.

산화질수(Nitric Oxide) 중단 후의 반동성폐고혈압 (Rebound Pulmonary Hypertension After Nitric Oxide Withdrawal)

  • 이현우;이재웅;현성열;박철현;박국양;이경천
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.132-138
    • /
    • 2000
  • Background: Inhaled nitric oxide therapy causes selective pulmonary vasodilation in congenital heart diseases with pulmonary hypertension. However discontinuation of inhaled nitric oxide therapy may be complicated by abrupt life-threatening rebound pulmonary hypertension(RPH) The purpose of this study was to prevent by comparing group I(without RPH n=13) and group II(with RPH n=6) to determine the risk factors involved inthe development of the RPH. Material and Method: Between Januarty 6, 1998 and April 14, 1999. we studied 19 consecutive children who were treated with inhaled nitric oxide for clinically significant pulmonary hypertension after an open heart surgery for congenital heart disease. the ratio of males and females was 12:7 ranging in age from 10 days to 6040 days(16 years) To identify the effects of nitric oxide between two groups we measured heart rate mean and systolic pulmonary arterial pressure mean and systolic systemic arterial pressure central venous pressure pH paO2/FiO2 and O2 saturation before and after the initiation and just before the withdrawal of the inhaled nitric oxide. result: In 6 of 19 patients(32%) withdrawal of inhaled nitric oxide caused RPH. In the two groups inhaled nitrix oxide decreased in pulmonary arterial pressure(PAP) without decreasing the systemic arterial pressure(SAP) and increased PaO2/FiO2 Compared with patients who had no RPH(group I) patients who had RPH(group II) were older in age (1204$\pm$1688 versus 546$\pm$1654 days p<0.05) received less nitric oxide therapy(34$\pm$18 versus 67$\pm$46 hours p<0.05) has shorter weaning process(5$\pm$3 versus 15一13 hours p<0.05) and received lowerconcentration of initial nitric oxide supply(11$\pm$8 versus 17$\pm$8 ppm p>0.05) and lower concentration just before the withdrawal nitric oxide(4.2$\pm$2.6 versus 5.6$\pm$2.6 ppm, p>0.05) Conclusion : We speculate that older age shorter of nitric oxide therapy shorter weaning process are the risk factors of RPH.

  • PDF

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.