• Title/Summary/Keyword: Connected surface

Search Result 627, Processing Time 0.026 seconds

The retrospective study of survival rate of implants with maxillary sinus floor elevation (상악동 거상술을 동반한 상악구치부에 식립된 임플란트 생존율에 대한 후향적 연구)

  • Kim, Beom-Jin;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.108-118
    • /
    • 2010
  • Introduction: Maxillary posterior region, compared to the mandible or maxillary anterior region, has a thin cortical bone layer and is largely composed of cancellous bone, and therefore, it is often difficult to achieve primary stability. In such cases, sinus elevation with bone graft is necessary. Materials and Methods: In this research, 121 patients who had implant placement after bone graft were subjected to a follow-up study of 5 years from the moment of the initial surgery. The total survival rate, 5-year cumulative survival rate and the influence of the following factors on implant survival were evaluated; the condition of the patient (sex, age, general body condition), the site of implant placement, diameter and length of the implant, sinus elevation technique, closure method for osseous window, type of prosthesis and opposing teeth. Results: 1. The 5-year cumulative survival rate of total implants was 90.5%, there was no significant difference between sex, age, the site of implant placement, diameter and length of the implant, sinus elevation technique, and the type of opposing teeth. 2. Patients with diabetes mellitus < osteoporosis and smooth-surfaced machined group < hydroxyapatite (HA)-treated group and homogenous demineralized freeze dried allogenic bone (DFDB) bone graft only group had significantly lower survival rate. 3. With less than 4 mm of residual alveolar ridge height, lateral approach without closing the osseous window resulted in a significantly lower survival rate. 4. Restoration of a single implant showed a significantly lower survival rate, compared to cases where the superstructure was joined with several implants in the area. Conclusion: Patients with diabetes or osteoporosis need longer period of time for osseointegration compared to the normal, and the dentists must be prudent when choosing a surface treatment type and the bone graft material. Also, as the vertical dimension of the residual alveolar ridge can influence the result, staged implant placement should be considered when it seems difficult for the implant to gain primary stability from the residual bone with less than 4 mm of vertical dimension. It is recommended to obdurate the bone window and that the superstructure be connected with several impants in the peripheral area.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

Analysis of functional load on the dentated skull with unilateral molar loss during simulated bilateral clenching clenching (이악물기 치아접촉시 편측 구치 상실을 지닌 두개골의 부하분석)

  • Jeong, SeogJo;Jeong, SeungMi;Kang, DongWan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.245-256
    • /
    • 2001
  • The purpose of this study is to analyze the mechanical stress and displacement on the jaws during the simulated bilateral clenching task on the three-dimensional finite element model of the dentated skull with unilateral molar loss. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 2.0mm intervals. The fully assembled finite element model consists of the articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The FE model was used to simulate the bilateral clenching in intercuspal position. The loading condition was the force of the masseter muscle exerted on the mandible as reported by Korioth et al. degrees of freedom of the zygomatic region where the masseter muscle is attached were fixed as restraints. In order to reflect the actual action of the muscles force, the displacement of the region was attached where the muscle is connected to the temporal bone and restraint conditions were given values identical to values at the attachment region of the masticatory muscle but with the opposite direction of the reaction from when the muscle force is acted on the mandible. Although the mandible generally has higher displacement and von Mises stress than the maxilla, its mandibular corpus on the molar-loss side has a higher stress and displacement than the molar-presence side. Because the displacement and von Mises Stress was the highest on the lateral surface of mandibular corpus with molar loss, the stress level of the condyle on the molar-loss side is greater than that of the molar-presence side, which in turn caused the symphysis of the mandible to bend. In conclusion, the unilateral posterior bite collapse with molar loss under para-functional activities such as bruxism and clenching can affect the stress concentration on the condyle and mandibular corpus. It is therefore necessary to consider the biomechanical function of dento-skeleton under masticatory force while designing the occlusal scheme of restoration on alveolar bone with the posterior collapse.

  • PDF

The Morphology Study of Organ Surface BongHan Ducts and Corpuscle (장기표면의 내외봉한관과 봉한소체의 형태학적 관찰)

  • Ahn, Seong-Hun;Kim, Min-Su;Lee, Sang-Hun;Kwon, O-Sang;Kim, Jae-Hyo;Soh, Kwang-Sup;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.26 no.1
    • /
    • pp.79-84
    • /
    • 2009
  • Objective : In 1960's Bonghan Kim's team found BongHan(BH) ducts which were presumed as acupuncture meridians and BH corpuscles. They asserted Bonghan theory and SanAl theory which was involved in cell division and cell restoration. However, many other experiments which had been operated to demonstrate and find the existence of BH ducts had failed because of the secret of blue stain drugs. During the last several years, BongHan theory has been revived through experimental researches to find the anatomical structures of BH ducts and corpuscles by Soh's Biomedical Physics Lab. Soh's research team used the staining with Janus Green B, Alcian blue, nanoparticles and Acridine Orange. We used DAPI staining to find the existence of BH ducts and the corpuscles and to observe nuclear arrangement. Methods : We used japan white rabbits as experimental animals. BH ducts and corpuscles were stained with DAPI. The nucleus configuration in BH ducts stained with DAPI were observed with microscope. Results : In this study, we found thread like structures in silver white color distinguished from the blood vessels, nerves and lymph vessels. These thread like vessels in the linear duct shape were connected to same colored mass in the ball shape. Thread like structures we found could be separated easily from the surrounding other organ mass. The nuclei of the thread like structure in DAPI staining, are about 10${\sim}$20${\mu}m$ length, in rod shape and linear arrangement. Conclusion : We concluded that the thread like structure we found was same vessel reported by Soh's research team, BongHan ducts and corpuscle.

  • PDF

Studies on the anodic oxidation of some volatile organic halogen compounds(THM) (휘발성 할로겐 화합물(THM)의 양극 산화에 관한 연구)

  • Yoo, K.S.;Park, S.Y.;Yang, S.B.;Woo, S.B.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.264-273
    • /
    • 1997
  • Anodic oxidation reaction was applied to remove trihalomethanes in an aqueous solution. Each component was determined by using solid phase microextraction(SPME) fiber and GC-ECD. Anodic and cathodic compartments were separated in order to protect contaminants and connected by $KNO_3$-agar bridge. The calibration graphs of the 6 THM components were shown good linearlity from a few ppb up to a few hundreds ppb concentration level. Anodes such as platinum(Pt), titanium(Ti). zircornium(Zr), titanium metal coated with iridium(Ti-Ir), and glassy carbon coated with mixed valence ruthenium(mv Ru) were tried to remove the THMs at different potentials. The best result was obtained on the Ti-Ir anode applied 9 volts DC. The electrode could effectively remove almost all the THM components from the stirring solution within about 1.5 hours. The glassy carbon electrode coated with mixed valence ruthenium showed excellent removing effect at the begining, but the maximum removing level was remained at 60% probably due to the destruction of the electrode surface. The concentration of chloroform, however, tends to be increased due to the electrode reaction producing the component at the condition.

  • PDF

Structure and chemical durability of borosilicate glass-ceramics containing EAF dust (EAF dust가 포함된 붕규산염계 결정화 유리의 구조 및 화학적 내구성)

  • Ahn, Y.S.;Kang, S.G.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.2
    • /
    • pp.82-89
    • /
    • 2007
  • Glass-ceramics were fabricated by heat-treating a glass at $700^{\circ}C$/10hr which was obtained by melting a glass frit mixed with $40{\sim}80 wt%$ EAF dust at $1300^{\circ}C$/1hr. Dependence of crystal phase and bonding state change upon a compositional change and heat treatment condition were studied and the results was connected to the toxic characterization leaching procedure (TCLP) test data to investigate a chemical durability of the specimens. Increasing dust in a glass shifted the peak around $1000cm^{-1}$ to the lower frequency which was composed of two vibration peaks for the nonbridging oxygen at $960cm^{-1}$ and the bridging oxygen at $1050{\sim}1060cm^{-1}$. Also, the $B_2O_3$ structure of boroxol ring changed to a tetrhedral-, trigonal- and di-borate with dust addition. The Fe-O peaks in the glass-ceramics were observed which is consitent with XRD results of spinel formation. The surface of glass after TCLP test was severely cracked while there was no cracks on a glass-ceramics after TCLP test so the chemical durability of the glass-ceramics is superior than that of glass. The leaching concentration of Fe for the glass-ceramics containing EAF dust 80 wt% is 1/15 times lower than that of glass. The Zn leaching concentration fur the glass-ceramics containing dust < 70 wt% was higher than that of glass but its trend was reversed for the specimen of dust content > 80 wt% which could be concluded as correlated with occurrence of willemite phase.

Assessment of Defect Risks in Apartment Projects based on the Defect Classification Framework (효율적인 품질관리를 위한 공동주택 하자위험 분석)

  • Jang, Ho-Myun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.510-519
    • /
    • 2019
  • The aim of this study was to set a defect classification framework and evaluate the defect risks in apartment buildings For this, approximately 15,056 defect items for 133 apartment buildings were examined. As a result of the analysis, the major defect of the RC work was cracks, which were found mainly in public locations. Moreover, the RC work was found to exhibit a high defect risk of water problem and surface appearance, which are highly connected with cracks. Second, the finish work has a high defect risk because it is composed of various work types, and there are many kinds of materials and construction parts involved. Third, the major defects of the waterproof work were incorrect installation and missing tasks, which have high defect risks in the garage. This is because defects that require rework occur mainly in the underground garage. Based on these results, this study proposed countermeasures for defect risk management to be considered in the construction, handover, post-handover, and occupancy phases. These have been set in detail based on the three zones: low frequency high severity (LFHS), low frequency low severity (LFLS), and high frequency low severity (HFLS).

A Shape Control of Welded Joints to Improve Fatigue Strength (피로강도 향상을 위한 용접이음부의 형상제어에 관한 연구)

  • Kang, Chang Ib;Kook, Seung Kyu;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.479-492
    • /
    • 2004
  • When U-ribs of steel deck plates are connected at the field, overhead welding should be done with backing strips. Misalignments may occur and lead to eccentric moments as well as high stress concentrations at welded joints. In this study, stress analyses and fatigue tests were carried out. Stress analyses for U-ribs' welded joints with backing strips were performed with different misalignments, root shapes, root gaps, and backing strip sizes. From the stress analyses, the stress concentration factors increased with increasing misalignments and root gaps. With the fixed misalignments and root gaps, the stress concentration factors obtained in the case of the semi-circle root shape were lower than those in the case of the right-angle root shape. It was verified that backing strip sizes have little influence on stress concentration factors. The fatigue tests for U-ribs' welded joints with backing strips indicated that increased misalignments shorten fatigue life drastically and cracks usually initiate at the root of the base metal and are propagated to the weld bead surface. Based on the results of the stress analyses, root-shape control methods were developed to mitigate stress concentration by changing welding condition control, radius curvature, and flank angle.

3D Finite Element Analysis of High Tension Bolted Joints (고장력 볼트 이음부의 3차원 유한요소 해석)

  • Shim, Jae Soo;Kim, Chun Ho;Kim, Dong Jo
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.407-414
    • /
    • 2004
  • Bridges in common use are expected to have more varieties of load in their connected members and bolts than in construction. Faults in connection members or bolts occur so often according to the time flow. One of the purposes of this study is to find out the behavior and structural features of high-tension bolted joints with faults that are very difficult and cost much to find out through experimentation with finite element analysis. Another purpose of this study is to provide sufficient data, estimated experimental results, and the scheme of the test plate for an economical experimental study in the future. Surveys of bridges with a variety of faults and statistical classifications of their faults were performed, as was a finite element analysis of the internal stress and the sliding behavior of standard and defective bridge models. The finite element analysis of the internal stress was performed according to the interval of the bolt, the thickness of the plate, the distance of the edge, the diameter of the bolt, and the expansion of the construction. Furthermore, the analysis explained the sliding behavior of high-tension bolt joints and showed the geometric non-linear against the large deformation, and the boundary non-linear against the non-linear in the contact surface, including the material non-linear, to best explain the exceeding of the yield stress by sliding. A normally bolted high-tension bolt joint and deduction of bolt tension were also analyzed with the finite element analysis of bridge-sliding behavior.

An Automatic Transfer System of the Path for an Unmanned Machine in the Greenhouse (온실내 무인작업기를 위한 경로 자동변환 시스템 개발)

  • 김창수;이대원;이승기
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.237-243
    • /
    • 2000
  • Agricultural machine is currently operated by man power in the greenhouse, which is oppressively hot and humid, and is for a farmer not to work in comfortable circumstances. In the future, agricultural machine will not have to operate by man power, but it will need do by unmanned power. In order to put into the automatic and unmanned operation of agricultural machine, this system was designed and built to move through the fixed path in the greenhouse. This system was composed of guiders(wires), a limit switch, an operating equipment, its software for automatizing a machine in the greenhouse. The guider was connected between the wall pillars, and the equipment was able to slide over the fixed path made of the guider, by rectilinear and rotational motion. A micro mouse was developed with a stepping motor to calculate on the success rate of its operation with the system As might be expected, this system with the micro mouse was moved the moved the paths with a success rate of 100% on the flat plane surface in our laboratory. However, on the sand plane or the other materials plane, the success rate was not better than 80%. If the micro mouse were well operated, the success rate was would be 100%. Based on the results of this research, this system would be expected to operate well on the path made of a simple wire.

  • PDF