• Title/Summary/Keyword: Conformity Assessment

Search Result 98, Processing Time 0.028 seconds

Risk Assessment of Industrial Machines and Devices and Appropriateness of Their Safety Certification and Self-Declaration of Conformity (위험기계, 기구의 위험성 평가 및 안전인증 또는 자율안전확인의 적정성)

  • Choi, Gi Heung;Loh, Byoung Gook
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Severity and frequency of industrial accidents are typically used to assess the "absolute" risk associated with the industrial machines and devices ("items") which are subject to safety certification or self-declaration of conformity. However, the "relative" risk associated with a particular item can further be assessed based on unit severity and unit frequency where the total number of item in use is taken into account. This study first attempts to estimate the total number of each item in use which was recently selected for safety certification or self-declaration of conformity. The appropriateness of such selection is recapitulated based on the relative risk involved. Analysis results indicate that depending on items, the relative risk is differentiated from the absolute risk. Recent selection of items for safety certification or self-declaration of conformity is then revisited for its validity. The relative risk based on unit severity and unit frequency of industrial accidents, together with the absolute risk, may be used to further categorize items for safety certification or self-declaration of conformity in the future.

Research on the Actual Condition and Development of Operational Guide for Cooperation Group Standards Certification System (단체표준 인증제도 실태조사 및 운영지침개발)

  • Goh, Hyun-Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.2
    • /
    • pp.94-103
    • /
    • 2009
  • In relation to a certification system recently, it is coming out complains about make a rule of thumb certification, problems of after-service and duplication with government certifications. Also there is confusion in operating certification system to lack of properly rule to international standard. These impose a heavy burden on company in terms of times and costs and enhance competitiveness. Nevertheless, the survey was not built yet for the status and problems of the cooperation group standards certification System. So, this study purposes that research on the actual condition and development of operational guide for cooperation group standards certification system. In addition it ultimately improve the certification system for reliability and international competitive power. For more detail on this study, it would be considered conformity assessment, domestic/international conformity assessment and certification criteria. Also comparing survey result on the actual condition with international standards, develop operational guidelines to meet international standards.

Illumination Compensation Based on Conformity Assessment of Highlight Regions (고휘도 영역의 적합성 평가에 기반한 광원 보상)

  • Kwon, Oh-Seol
    • Journal of Broadcast Engineering
    • /
    • v.19 no.1
    • /
    • pp.75-82
    • /
    • 2014
  • This paper proposes an illuminant compensation method using a camera noise analysis without segmentation in the dichromatic reflectance model. In general, pixels within highlight regions include large amounts of information on the image illuminant. Thus, the analysis of highlight regions provides a relatively easy means of determining the characteristics of an image illuminant. Currently, conventional methods require regional segmentation and the accuracy of this segmentation then affects the illuminant estimation. Therefore, the proposed method estimates the illuminant without segmentation based on a conformity assessment of highlight regions. Furthermore, error factors, such as noise and sensor non-uniformity, can be reduced by the conformity assessment.

Fire Risk Assessment of Building Use Types Using Natural Breaks (Jenks) (자연적 구분법을 이용한 건축물 용도별 화재위험도 평가)

  • Lee, Kyu Min;Lim, Hyeon Seok;Cho, Jae Woo;Lee, Sang Kwon;Min, Se Hong;Min, Jeong Ki
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.63-71
    • /
    • 2019
  • This study quantitatively analyzed the fire risk of buildings by use nationwide, fire occurrence, and the statistical data of buildings by use. Fire incidents and buildings' statistics from the past 10 years (2008-2017) were used and classified as "Building Laws" and "Enforcement Decree of the Act on the Installation, Maintenance, and Safety of Fire Facilities" to be used for the relative assessment under the Natural Breaks as a risk matrix. In addition, after conducting risk assessment using 2018 fire occurrence data, we compared and analyzed the same with past 10 years' data. The results showed that most facilities had similar risk grades, except for the results of reduced risk levels from IV to II in recreational facilities, confirming the past and present data correlations as valid. Hence, the classification method is deemed appropriate. Through the results, the fire risk assessment of buildings by use nationwide are presented as a reference for fire safety.

A Study of Innovation Policy regarding Technical Regulation and Conformity Assessment Procedure on ICT Equipments - Focused on Privatization Plan (CT 분야의 기술기준 및 적합성평가시스템의 혁신정책에 관한 연구: 민간화 방안을 중심으로)

  • Lee, Yong-Kyu
    • Journal of Korea Technology Innovation Society
    • /
    • v.19 no.3
    • /
    • pp.439-464
    • /
    • 2016
  • The technical regulation and conformity assessment procedure of our country on ICT equipments is currently required to have more innovation due to the request of main trade countries, the second phase conclusion of MRA, necessity of expansion of conformity assessment service market and demand of manufacturers. The world's leading advanced countries have already proceeded with innovation based on privatization plan. According to the comparative analysis of the level, it turned out that Japan obtained the highest level of privatization while South Korea ranked the lowest level. According to the research result of examination and certification ability of private institutions of our country, it turned out that our country is expected to have possibility of achieving higher level of privatization than that of the present. Moreover, according to the questionnaire survey conducted to the persons concerned regarding privatization direction, they gave positive response to all the indicated survey contents of privatization direction in terms of "delegation of certification services to private sectors (contracting-out)", "transformation of EMC into private voluntary standard" and "changeover of conformity assessment agent". However, from the view of acceptance and conflict model, it is estimated that starting from "delegation of certification services to private sectors (contracting-out)" seems to be the most advisable plan. Also, prior to privatization, it is required to improve relevant systems such as certification examiner system.

Evaluation of Severity Measures of Accidents Associated with Industrial Machines and Devices (산업용 기계 및 기구 관련 재해강도 지표의 평가)

  • Choi, Gi Heung
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.2
    • /
    • pp.1-6
    • /
    • 2019
  • This study focuses on the evaluation of severity measures used for accidents associated with industrial machines and devices. In particular, duration of medical treatment, duration of work loss, number of deaths in an individual accident associated with industrial machines and devices are evaluated in various ways to assess the severity of the accident. The number of accidents with work loss of longer than 1 year as the severity measure and the number of accidents as the frequency measure appeared to be the most discriminating information and allow risk assessment based on these frequency and severity measures for grouping of industrial machines and devices. Results of such risk assessment further confirmed the re-classification of industrial machines and devices that are currently subject to safety certification (SC) and self-declaration of conformity (SDC) or selection of those machines and devices that are newly subject to SC and SDC.

Conforming Assessment and Requirements for Recognition/Accreditation Bodies (적합성평가 및 인증/인정 기관 요구사항)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.299-303
    • /
    • 2007
  • This paper deals with conformity assessments requirements for accreditation and certification bodies. This study also introduces conformity guidances of product certification and code of good practice. This paper presents general requirements for accreditation, recognition and registration bodies of environmental quality system and product certification.

  • PDF

THE JAPANSE STATUS OF LABORATORY ACCREDITATION BASED ON FASTENER QUALITY ACT.

  • Aoyagi Tutomu;Imai O Yoshio
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.339-344
    • /
    • 1998
  • Since 1997, JAB (The Japan Accreditation Board for Conformity Assessment) had started the activity of accreditation for the laboratory based on U.S. PL101-592: the Fastener Quality Act that was signed by President Bush on 1990. The number of accredit laboratories are 69 in Japan, 21 in Taiwan, 2 in Korea and 189 in U. S. A, as of 09/10/1998. The JAB accreditation encompasses the requirements of the ISO/IEC Guide 25, and the relevant requirements of ISO 9002. The purpose of ISO/IEC Guide 25, also had been harmonized as JIS Z 9325 'General requirements for the competence of calibration and testing laboratories 'mainly facilitates and promotes acceptance of calibration and test results between countries to avoid barriers to trade through as 'one stop testing'. The features and differences between Guide 25 and ISO 9000 will be clarify in this report.

  • PDF

Residue Characteristics and Risk Assessment of Pesticides (Boscalid and Pyraclostrobin) in Hylomecon vernalis (피나물 중 boscalid 및 pyraclostrobin의 토양 처리시 잔류특성 및 안전성 평가)

  • Yu, Ji-Woo;Song, Min-Ho;Kim, Jinchan;Lee, Kwanghun;Ko, Rakdo;Keum, Young-Soo;Lee, Jiho
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.2
    • /
    • pp.95-100
    • /
    • 2022
  • BACKGROUND: This study was aimed to determine characteristics of residues of the soil-treated boscalid and pyraclostrobin within Hylomecon vernalis and to evaluate the risks from intake of the residual pesticides in the crop. METHODS AND RESULTS: The pesticides were treated to soils at two different concentrations, and the plant samples were collected 57 days after seeding. The samples were extracted using the QuEChERS extraction kit (MgSO4 4 g, NaCl 1 g). The quantitative methods for boscalid and pyraclostrobin were validated using linearity, recovery, and CV (coefficient of variation). Risk assessment of the pesticides was performed using Korea national nutrition statistics 2019. CONCLUSION(S): The residual levels of boscalid were 0.02-0.05 mg/kg (for the treatment at 6 Kg/10a) and 0.05-0.08 mg/kg (for the treatment at 12 Kg/10a), respectively. The residual concentrations of pyraclostrobin were below the LOQ. The amounts of pesticides were less than Maximum Residue Limits specified by the Korean Ministry of Food and Drug Safety. The maximum hazard indices of boscalid in chwinamul and amaranth for consumers were 0.0075% and 0.1525%, respectively, and it indicates that the risk of the pesticides from the crop is considered to be low.