• 제목/요약/키워드: Conformal

검색결과 770건 처리시간 0.027초

DED방식의 적층가공을 통한 금형으로의 응용사례 및 효과 (Effects and Application Cases of Injection Molds by using DED type Additive Manufacturing Process)

  • 김우성;홍명표;김양곤;서창희;이종원;이성희;성지현
    • Journal of Welding and Joining
    • /
    • 제32권4호
    • /
    • pp.10-14
    • /
    • 2014
  • Laser aided Direct Metal Tooling(DMT) process is a kind of Additive Manufacturing processes (or 3D-Printing processes), which is developed for using various commercial steel powders such as P20, P21, SUS420, H13, D2 and other non-ferrous metal powders, aluminum alloys, titanium alloys, copper alloys and so on. The DMT process is a versatile process which can be applied to various fields like the mold industry, the medical industry, and the defense industry. Among of them, the application of DMT process to the mold industry is one of the most attractive and practical applications since the conformal cooling channel core of injection molds can be fabricated at the slightly expensive cost by using the hybrid fabrication method of DMT technology compared to the part fabricated with the machining technology. The main objectives of this study are to provide various characteristics of the parts made by DMT process compared to the same parts machined from bulk materials and prove the performance of the injection mold equipped with the conformal cooling channel core which is fabricated by the hybrid method of DMT process.

Chemotherapy and Late Course Three Dimensional Conformal Radiotherapy for Treatment of Patients with Stage III Non-small Cell Lung Cancer

  • Liu, Yang-Chen;Zhou, Shao-Bing;Gao, Fei;Ye, Hong-Xun;Zhao, Ying;Yi, Xiao-Xiang;Huang, Xin-En;Xiang, Jin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2663-2665
    • /
    • 2013
  • Objective: To compare the efficacy and complications of chemotherapy and late course three-dimensional conformal radiotherapy (3DCRT) in treating patients with stage III non-small cell lung cancer (NSCLC). Patients and Methods: All patients were divided into two groups: to receive chemotherapy and late course 3DCRT (3DCRT group), or chemotherapy and conventional fraction radiation (control group). In the 3DCRT-group, patients were given 6~15 MV X-rays with a total dose of 40 Gy, followed by 3DCRT, 2.5 Gy~3.0 Gy per fraction, 1 fraction/every day, total 68 Gy~70 Gy; in the control group, with conventional fraction radiation the total dose was 64~66 Gy. The chemotherapy regimen in both cases was EP (VP-16 and DDP). Results: Sixty four patients with stage III NSCLC were divided into two groups: 32 patients into 3DCRT, 32 into the control group. One and 2-year survival rates in 3DCRT and control group were 87.5%, 56.3%mad 65.6%, 34.4%, respectively (P<0.05); local control rates were 90.6%, 81.3% and 65.6%, 53.1%, respectively (P<0.05). Conclusion: Chemotherapy and late course 3DCRT is associated with improved survival rate in patients with stage III NSCLC with good tolerability.

향상된 적응형 유전 알고리즘을 이용한 컨포멀 배열 안테나의 빔 합성 연구 (Study on Pattern Synthesis of Conformal Array Antenna Using Enhanced Adaptive Genetic Algorithm)

  • 성철민;이재덕;한인희;류홍균;이규송;박동철
    • 한국전자파학회논문지
    • /
    • 제25권5호
    • /
    • pp.592-600
    • /
    • 2014
  • 본 논문에서는 2차 함수 곡선의 회전체 곡면 위에 있는 배열 안테나의 빔 합성을 위한 Enhanced Adaptive Genetic Algorithm(EAGA)을 제안하였다. 제안된 알고리즘은 더 빠른 수렴 속도와 더 낮은 비용함수 값을 얻기 위해 Adaptive Genetic Algorithm(AGA)과 Invasive Weed Optimization(IWO)을 결합시켰다. 각 안테나 소자의 급전 크기와 위상의 최적화된 값은 EAGA를 통해 구하였으며, 이 결과를 통해 EAGA가 컨포멀 배열 안테나의 패턴 합성 알고리즘으로써 AGA보다 더 우수함을 보였다.

Clinical Observation of Three Dimensional Conformal Radiotherapy with Tamoxifen in Treatment of Postoperative Malignant Glioma

  • Zhou, Shao-Bing;Liu, Yang-Chen;Yin, Xiao-Xiang;Ding, Wen-Xiu;Guo, Xin-Wei;Gu, Liang;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1743-1745
    • /
    • 2015
  • Objective: To evaluate the efficacy and adverse effects of three dimensional conformal radiotherapy (3D-CRT) with tamoxifen in treating patients with postoperative malignant glioma. Patients and Methods: 60 patients of postoperative malignant glioma were randomly assigned into two groups, 30 patients were treated with 3D-CRT plus tamoxifen (treatment group), and the other 30 patients with 3D-CRT plus temozolomide (control group). All patients were radiated by 6MV X-ray, 2.0Gy per fraction, once daily, with a total dose (DT) of 56~60Gy. Tamoxifen was delivered at $60mg/m^2/d$, temozolomide was given at $75mg/m^2/d$. All patients were treated with concurrent radiotherapy. Results: One, 2, 3 year survival rates of treatment and control group were 63.3%, 30.0%, 23.0% and 70.0%, 33.3%, 26.7%, respectively (${\chi}^2=0.01$, 0.23, 0.09, P>0.05). The rate of thromboembolism in treatment group was 6.7%. Conclusion: Therapeutic efficacy of two groups was similar, but it was more cost-effective in treatment group, and toxicity did not increase.

TCO 응용을 위한 패턴된 기판위에 증착된 AZO 박막의 특성 연구 (Conformal coating of Al-doped ZnO thin film on micro-column patterned substrate for TCO)

  • 최미경;안철현;공보현;조형균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.28-28
    • /
    • 2009
  • Fabrications of antireflection structures on solar cell were investigated to trap the light and to improve quantum efficiency. Introductions of patterned substrate or textured layer for Si solar cell were performed to prevent reflectance and to increase the path length of incoming light. However, it is difficult to deposit conformally flat electrode on perpendicular plane. ZnO is II-VI compound semiconductor and well-known wide band-gap material. It has similar electrical and optical properties as ITO, but it is nontoxic and stable. In this study, Al-doped ZnO thin films are deposited as transparent electrode by atomic layer deposition method to coat on Si substrate with micro-scale structures. The deposited AZO layer is flatted on horizontal plane as well as perpendicular one with conformal 200 nm thickness. The carrier concentration, mobility and resistivity of deposited AZO thin film on glass substrate were measured $1.4\times10^{20}cm^{-3}$, $93.3cm^2/Vs$, $4.732\times10^{-4}{\Omega}cm$ with high transmittance over 80%. The AZO films were coated with polyimide and performed selective polyimide stripping on head of column by reactive ion etching to measure resistance along columns surface. Current between the micro-columns flows onto the perpendicular plane of deposited AZO film with low resistance.

  • PDF

Moderately Hypofractionated Conformal Radiation Treatment of Thoracic Esophageal Carcinoma

  • Ma, Jin-Bo;Wei, Lin;Chen, Er-Cheng;Qin, Guang;Song, Yi-Peng;Chen, Xiang-Ming;Hao, Chuan-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권8호
    • /
    • pp.4163-4167
    • /
    • 2012
  • Aims: To prospectively assess the efficacy and safety of moderately hypofractionated conformal radiotherapy in patients with thoracic esophageal cancer. Methods and Materials: From Sept. 2002 to Oct, 2005, 150 eligible patients with T2-4N0-1M0 stage thoracic esophageal squamous cell cancers were enrolled to receive either conventional fractionated radiation (CFR) or moderately hypofractionated radiation (MHR) with a three-dimensional conformal radiation technique. Of the total, 74 received moderately hypofractionated radiation with total dose of 54-60Gy/18-20fractions for 3.5-4 weeks in the MHR arm, and 76 received conventional radiation with total dose of 60Gy/30 fractions for 6 weeks in the CFR arm. Concurrent chemotherapy comprised of paclitaxel and cisplatin. Safety was evaluated, and local control and overall survival rates were calculated. Results: Statistically significant differences between the CFR versus MHR arms were observed in local/regional failure rate (47.3% v 27.0%, P=0.034) and the percentage of patients with persistent local disease (26.3% v 10.8%, P=0.012). But 3 and 5-year overall survival rates (43.2%, 38.8% v 38.2%, 28.0%, respectively) were not different between the two arms (P=0.268). There were no significant differences in the incidences of grade 3 or higher acute toxicities (66.3% v 50.0%) and late complications rates (27.0% v 22.4%) between the MHR and CFR arms. Conclusions: Moderately hypofractionated, three-dimensional radiation treatment could improve the local control rate of esophageal cancer and potentially increase patients' survival.

준등각 맵핑 기반 전자기파 투명화 구조의 실험적 검증 (Experimental Verification of Electromagnetic Cloak Based on Quasi-Conformal Mapping)

  • 김용준;서일성;고일석;이용식
    • 한국전자파학회논문지
    • /
    • 제27권6호
    • /
    • pp.491-494
    • /
    • 2016
  • 본 논문에서는 준등각 맵핑 기반 전자기파 투명화 구조의 산란 단면적(Scattering Cross Section: SCS)을 최소화 시키는 설계 방법을 제시한다. 준등각 맵핑에 기반하여 설계한 전자기파 투명화 구조를 사각형 형태로 잘라낸 뒤 경계면 밖의 굴절률과 내부의 1미만인 굴절률을 자유 공간으로 근사하는 방법을 사용함으로써 구현하기 어려운 굴절률 문제를 해결하였다. 사각형 형태의 크기는 시뮬레이션을 통해 전자기파 투명화 구조를 적용한 마름모형 금속 물체의 산란 단면적이 최소가 되도록 최적화하였다. 설계된 자유 공간형 전자기파 투명화 구조를 3D 프린터를 이용하여 제작, 산란파 저감 특성을 전자기장 스캐너를 이용하여 실험적으로 검증하였다.

탄성층에 삽입된 음향 하이드로폰의 외부 유입소음 영향 연구 (Investigation of Outer Flow Noise Reduction of the Hydrophones Embedded in the Elastomer)

  • 박지혜;이종길;신구균;조치영
    • 대한공업교육학회지
    • /
    • 제33권2호
    • /
    • pp.273-286
    • /
    • 2008
  • 수중에서 UUV(Unmanned Underwater Vehicle)에 장착되는 수중 음향 센서 배열은 UUV의 측면이나 전면에 부착하여 외부 신호를 탐지하게 된다. 이러한 센서 배열은 UUV의 특성상 곡면배열(Conformal array) 형태이며 유체 유기 소음의 영향을 받는다. 따라서 본 논문에서는 탄성층에 삽입된 하이드로폰이 외부 유입 소음의 영향을 받는 정도를 해석하였다. 유입 소음은 난류 경계층에서 발생하는 Corcos 모델을 이용하였고 주파수 밀도 함수를 이용하여 수치해석 하였다. x-방향의 파수인 kx에 다른 전달함수의 특성은 탄성층의 두께가 커질수록 전달함수의 적분값은 적어지므로 소음의 영향은 줄어드는 것으로 나타났다. 또한 탄성층 및 고정판의 탄성계수, 밀도 등의 변화가 전달함수 값의 변화를 일으키는지를 조사하였다. 향후 이러한 연구는 UUV에 장착되는 곡면 배열 센서의 설계에 활용할 수 있을 것으로 판단된다.