• Title/Summary/Keyword: Confocal measurement

Search Result 83, Processing Time 0.023 seconds

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Phase-shifting diffraction grating interferometer for testing concave mirrors (오목 거울 측정용 위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.392-398
    • /
    • 2003
  • We present a novel concept of a phase-shifting diffraction-grating interferometer, which is intended for the optical testing of concave mirrors with high precision. The interferometer is configured with a single reflective diffraction grating, which performs multiple functions of beam splitting, beam recombination, and phase shifting. The reference and test wave fronts are generated by means of reflective diffraction at the focal plane of a microscope objective with large numerical aperture, which allows testing fast mirrors with low f-numbers. The fiber-optic confocal design is adopted for the microscope objective to focus a converging beam on the diffractive grating, which greatly reduces the alignment error between the focusing optics and the diffraction grating. Translating the grating provides phase shifting, which allows measurement of the figure errors of the test mirror to nanometer accuracy.

Investigation of Coke Formation on H-ZSM-5 Catalyst During Aromatization of C5 Paraffin and Olefin Using Optical and Fluorescence Microscopy

  • Chung, Young-Min
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.327-332
    • /
    • 2013
  • Space- and time-resolved in-situ optical and fluorescence microspectroscopy techniques have been applied to investigate the coke formation during aromatization of C5 paraffin and olefin over H-ZSM-5 crystal. In-situ UV/vis absorption measurement offers space- and time-resolved information for the coke formation. Different coking trends have been observed with respect to the location of a crystal as well as the reactant types. From in-situ confocal fluorescence microspectroscopy study, it is revealed that the concentration of certain species photo-excited at 488 nm becomes high at the central region, whereas the compounds emitting fluorescence by 561 nm laser move towards the boundary region of the crystal. The different fluorescence patterns obtained varying excitation lasers suggest the existence of distinct fluorescence emitting species having different degree of coke growth.

Sheet Formation Properties of Morus Hanji (뽕나무 한지의 지합특성)

  • Yi, Il-Roh;Cho, Nam-Seok
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.3 s.116
    • /
    • pp.47-60
    • /
    • 2006
  • This study was carried out to investigate the sheet formation properties of Morus Hanjis, made of bast and whole stalk pulps by different pulping methods, such as alkali, alkali-peroxide and sulfomethylated pulping. Two species of Morus, M. alba and M. lhou, were used. Effect of morphological properties of pulp stocks on the sheet formation and its gray levels based on optical property were evaluated using an Image analyzer. In addition, the effect of fiber distribution index(FDI) which was calculated from tile data of Confocal laser scanning microscopy(CLSM) on the sheet formation and optical properties of Morus Hanji were also discussed. On the sheet formation, Hanji from whole stalk pulp was superior than that of bast pulp. The more the sheet formation improved, the more paper opacity decreased. In the aspect of Hanji's surface characteristics analyzed by an Image analyzer, the average gray level and its standard deviation of Hanji from the whole stalk pulp were rather lower than those of bast pulp because of better sheet formation of the former. However, high brightness Hanji showed high value of gray level. The sheet formation and paper opacity were increased with the decrease of standard deviation of gray level. From these results, gray level measurement could be used to predict the paper opacity as well as sheet formation. Sheet formation of whole stalk Hanji and its FDI measured by CLSM were higher than those of bast fibers. In conclusion, the sheet formation and opacity of Hanji could be evaluated by standard deviation value of Hanji's gray level using an Image analyzer and by fiber distribution index using CLSM.

The Cosmeceutical Property of Antioxidant Astaxanthin is Enhanced by Encapsulation Using Glyceryl Based New Vesicle (글리세릴 베이스의 신규베지클 이용 캡슐화를 통한 항산화성 아스타잔틴의 성질 강화)

  • Kim, Dong Myung;Hong, Weon Ki;Kong, Soo Sung;Lee, Chung Hyun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.3
    • /
    • pp.247-257
    • /
    • 2014
  • Oil-in-water nanoemulsions of astaxanthin prepared by new vesicle, glyceryl citrate/ lactate/ linoleate/ oleate, were evaluated thoroughly in terms of cosmeceutical properties such as antioxidant effect, cell viability, influence of protein related enzyme, skin penetration, skin hydration and elasticity. Antioxidant effect and cell viability of nanoemulsion of astaxanthin were evaluated by DPPH and MTT assay. Also other properties of nanoemulsions of astaxanthin were measured by proteome analysis using 2D-PAGE, confocal laser scanning microscope and in-vivo test. We were able to find that the nanoemulsion of astaxanthin is good at scavenging of radical and inhibits the degradation of dermal extracellular matrix with the down-regulation of MMPs and other proteins related to MMP expression. CLSM was adopted for observing penetration of nanoemulsion of astaxanthin and showed high effective penetration rate compared to the nanoemulsion of astaxanthin prepared by conventional lecithin. In-vivo measurement of the nanoemulsions in hydration and elasticity were conducted to 11 Korean female adults for 28 days and showed better results.

A Slice Information Based Labeling Algorithm for 3-D Volume Data (Slice 정보에 기반한 3차원 볼륨 데이터의 레이블링 알고리즘)

  • 최익환;최현주;이병일;최흥국
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.7
    • /
    • pp.922-928
    • /
    • 2004
  • We propose a new 3 dimensional labeling method based on slice information for the volume data. This method is named SIL (Slice Information based Labeling). Compare to the conventional algorithms, it has advantages that the use of memory is efficient and it Is possible to combine with a variety of 2 dimensional labeling algorithms for finding an appropriate labeling algorithm to its application. In this study, we applied SIL to confocal microscopy images of cervix cancer cell and compared the results of labeling. According to the measurement, we found that the speed of Sd combined with, CCCL (Contour based Connected Component Labeling) is almost 2 times higher than that of other methods. In conclusion, considering that the performance of labeling depends on a kind of image, we obtained that the proposed method provide better result for the confocal microscopy cell volume data.

Can Daily-use Lipstick Make Lips More Fresh and Healthy\ulcorner - A New Lipstick Containing $\alpha$-Glucosyl-hesperidin Can Remove the Dull-color from Lips

  • Iwai, I.;Yamashita, T.;Ochiai, N.;Masuda, Y.;Hosokawa, K.;Kohno, Y.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.162-177
    • /
    • 2003
  • It has been known that the color of skin reflects the blood flow within. In lips, the capillaries close to the skin surface are numerous; hence lips are redder than the rest of face. However, dermatological research on lips is not as advanced as research on facial or body skin, and little was known about the relationship between relatively dull-colored lips and skin blood flow. The physiological differences between colorful and dull-colored lips were studied by a two-dimensional laser Doppler blood flow analyzer, a spectrometer for the measurement of the degree of oxygen saturation, and a confocal microscope for observing inside lips non-invasively. Dull-colored lips and the corner of lips (dull-colored compared to the center) showed relatively poor blood flow and lower oxygenated hemoglobin. It was found that colorful lips (generally the young) had a blood flow that tended to run straight in parallel with the skin surface. This unique blood-capillary structure can express clear red blood. Those with dull-colored lips had lost this unique structure. Their blood ran perpendicularly from the deep of the skin and down back again into the deep part as like the blood circulation patterns of facial skin. Therefore, the lips of the latter group had fewer blood capillaries near skin surface in the lips than that of the colorful-lips group. A lipstick containing a-glucosyl-hesperidin, which is derived from certain citrus fruits and can enhance blood circulation, was applied for evaluating its effects. Blood flow was increased 30 min after the application. After two weeks of daily application, the lips' condition became noticeably less dull. These findings suggest that the decrease of blood flow in dull-colored lips is caused by the loss of the unique capillary structure and the use of the lipstick to increase blood flow can give a vivid color to lips.

  • PDF

Noninvasive Depthwise Temperature Measurement in Skin Tissue Using Laser Speckle Imaging Technique (레이저 스펙클 이미징 기법을 이용한 피부 조직의 깊이 방향 비침습적 온도 측정)

  • Jakir Hossain Imran;Noemi Correa;Jung Kyung Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.74-81
    • /
    • 2024
  • Accurate tissue temperature monitoring during clinical procedures, such as laser therapy or surgery, is crucial for ensuring patient safety and treatment efficacy. Noninvasive techniques are essential to prevent tissue disturbance while providing real-time temperature data. However, current methods often struggle to accurately measure temperature at various depths within the skin, which is essential to avoid damage to surrounding healthy tissues due to excessive heat. In response to this challenge, we developed a confocal imaging system that utilizes the laser speckle imaging (LSI) technique for precise depthwise temperature monitoring. LSI uses laser light scattering to capture subtle changes in speckle patterns on the skin's surface due to temperature fluctuations within the tissue. By analyzing these changes, LSI enables accurate depth-resolved temperature measurements. This technique enhances the precision and safety of medical procedures, offering significant potential for broader clinical applications, improved patient outcomes, and better thermal management during interventions.

Measurement of fluorecence decay times of single molecules in solution (용액내 단분자의 형광소멸시간 계측)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.1-4
    • /
    • 1999
  • A confocal microscope system was used to study the bursts of fluorescence photons from single dye molecules excited at 638 nm by a short-pulsed diode laser with a repetition rate of 17 MHz. A red dye, JA22, in ethylene glycol solution was used as a sample. The fluorescence decay curves of single molecules were acquired using a time-correlated single photon counting and analyzed by a maximum likelihood estimator. It was possible to measure the fluorescence decay times with an error probability of 21% at photon number of more than 40 per dye molecule.

  • PDF

Measurement and Effective Deburring for the Micro Burrs in Piercing Operation

  • Ko, Sung-Lim
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.152-159
    • /
    • 2000
  • In piercing operation for small hole in very thin plate, micro burrs are formed. The micro burr is very difficult to remove because the thin plate is to be deformed during deburring and deteriorate accuracy. As a first step to remove the micro burrs effectively, the burr must be measured accurately as much as possible. For most micro burrs are so small as less than 10$\mu\textrm{m}$, it is very difficult to measure. Several methods are reviewed to measure the micro burr formed in piercing operation from very thin plate with thickness less than 0.1mm. Also the effective deburring methods are reviewed. Barreling ultrasonic and chemical deburring methods are performed and the results are compared.

  • PDF