• Title/Summary/Keyword: Confidence Level

Search Result 1,967, Processing Time 0.025 seconds

Effects of the Upright Body Type Excercise on Lung Capacity and Depression of People with Mental Illness (바른체형운동 지도가 정신장애인의 우울감 및 폐활량에 미치는 효과)

  • Woo, Kyung-Hee;Yang, Jeong-Ok;Lee, Joong-Sook;Lee, Bom-Jin;Kim, Eui-Suk;Jung, Sook-Hee;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.26 no.10
    • /
    • pp.1169-1181
    • /
    • 2016
  • The purpose of this study was to investigate the effects of the regular Upright Body Type Excercise on posture, muscle strength of leg, lung capacity and depression of people with mental illness. The subjects of this study were recruited from B mental health center (5 years and more mental illness patients, n=19) located in P city. For the exercise group, They were carried out the Upright Body Type Excercise Program during 8 weeks (60 min/time, 3 times/week). They were randomly divided into two groups. Exercise group (n=10) and Control group (n=9). And also, they were agreed with consent forms before the experiments. Research results were as follows. Through the upper body type exercise, there was significantly difference in PEF and FEV1/FVC in the trained group. And also, there was much improved in depression level in the trained group. The change of melancholy feeling before and after the program was not statistically significant. However, because of limitations of sampling size due to the peculiarities of the program participants, in consideration of the limit of statistical validation exists clearly, intended to better understand the subjective experience of attendees, qualitative analyzing(qualitative research) was carried out in parallel. It was conducted a deep interview only person accepted among program participants, thematic analysis, subject analysis tasks to be subdivided by classifying by considering the semantic units of what participants expressed, was thus carried out. It found that the degree of melancholy feeling of mental disorders who participated in the Upright Body Typed Exercise Program was reduced. The course of the experience of change in depression appered the three subjects and six sub-themes such as "the start of the change", "interest of the program", "recognition of the need of the body’s health", "physical health promotion", "recovery of physical function", "negative change of habits (attitude)", "reduction of sense of depression", "confidence that it is possible to", "hope for the future". Therefore, upper body type exercise is much helpful in lung capacity and mental health of people with mental illness. So, this type of exercise mostly needed in the people with mental illness group than the other group for the quality of life.

A Case Study on Characteristics of the Mathematics Gifted Children (수학영재의 특성에 관한 사례연구)

  • Kim, Min-Jung;Ryu, Sung-Rim
    • Education of Primary School Mathematics
    • /
    • v.10 no.1 s.19
    • /
    • pp.41-56
    • /
    • 2007
  • Related with the mathematics gifted children the situation of different case studies is the research which is limited in mathematics problem solving process of the most mathematics gifted children. The research which it sees hereupon observes from the scope which is wider the quality of the mathematics gifted children, before the hazard mathematics gifted children whom it sees enter into the mathematics gifted children education center unit life and life after studying living and dismissal of a class from the general school, namely for their general life it leads compared to attitude it observes the reporter it does a quality. For a what kind of interest in the mathematics gifted children, the research leads the family or general class, from the gifted children education center it has it considers encouragement, map and to give a help to good mathematics gifted children education activation, it does. It will reach and to respect with afterwards it set a same three research problem. First, before entering into the mathematics gifted children education center, are the mathematics gifted children what kind of quality? Second, Are the mathematics gifted children what kind of quality for general school hour? Third, Are the mathematics gifted children what kind of quality after dismissal of a class after hour? Being selected in the hazard gifted children education center which solves an up research problem, simple characteristic and approach ease characteristic, by the condition of the permission possibility back it selected 2 person gifted children school boxes which are coming and going. And, before entering into these mathematics gifted children education center, studying life from the general school, life after dismissal of a class it will extend at 1 years, various recording it will ask and it collected direct observation and interview it led against their quality it analyzed. It shared the result which it analyzes with emotional quality, studying conduct qualities, general qualities of the mathematics gifted children and qualities of mathematics gifted children parents. Studies level of the mathematics gifted children parents high facility when them are young from, the interest and helping out which it has were considerable, to advance with the direction where in order for always with great disaster them are proper the map it did. In general quality of the mathematics gifted children from young age the ability which finds a language and a possibility concept superiorly the ability which expresses the thought of oneself logically was superior, the competitive spirit was high, it liked it came reading, a leader role, to reveal a deepening school with the fact that it comes and goes. Also it will burn with their studying conduct quality and it will roll and it did deeply and it arranged knot eagerly, accomplishing which is superior from the field which is various it showed, the originality was superior, the subject attachment power was high quite, oneself it studies it has a devotion the possibility of knowing it was. And, the social characteristic of the friends and is good with their emotional quality and it does there is own reflection and an encouragement at any time and also a confidence, but just as good as the stress also it receives the possibility of knowing it was to him.

  • PDF

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.

Comparison of Population Monitoring Methods for Breeding Forest Birds in Korean Temperate Mixed Forests (국내 온대 혼효림에 서식하는 산림성 조류의 번식기 개체군 모니터링 방법에 대한 비교)

  • Nam, Hyun-Young;Choi, Chang-Yong;Park, Jin-Young;Hur, Wee-Haeng
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.4
    • /
    • pp.663-674
    • /
    • 2019
  • Birds are effective ecological indicators but there is no national protocol in place to monitor population dynamics of forest birds in Korea. To support the establishment of future monitoring protocols, we compared the results of two generally used monitoring methods for forest bird surveys in two temperate mixed forests in central Korea. There was no statistical difference in the number of species and individuals detected per unit survey effort when comparing line transects and point counts. The number of species and individuals were higher in a five-minute count than in a three-minute point count, but the total accumulated number of expected observed species showed no difference between the two count durations. The number of observed species and individuals increased in both methods as plot radius or transect width increased, suggesting that multi-layer or multi-band surveys may be useful for quantitative and qualitative objectives. The decreasing number of observed species and individuals after sunrise suggested that bird monitoring should be conducted earlier in the morning, within four hours after sunrise. To detect 70% of the total number of species, 7.0 to 7.6 survey hours, equivalent to 42 three-minute counts (95% confidence interval [CI]: 26 to 61) or 33 five-minute counts (95% CI: 19 to 53) were needed for unlimited radius point counts. On the other hand, 4.8 survey hours, equivalent to 26 line transect counts (95% CI: 15 to 45) using 200-m transects with unlimited width, were required to achieve the same level of species detection. Therefore, the line transect method may be more effective than the point count method, at least in terms of local species richness assessment. For national forest bird monitoring, our data indicated that one or both survey methods can be selected as a basic protocol, based on the goals and scales of monitoring, forest types, and the conditions of the target areas.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF

The Utilization Rate of Community Health Practitioner Post by Some Rural Residents and Its Associated Factors (일부 농촌지역 주민의 보건진료소 이용도와 관련요인)

  • Lee, Woon-A;Ryu, So-Yeon;Park, Jong;Kim, Suk-Il;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.1
    • /
    • pp.133-147
    • /
    • 2000
  • To provide data for the improvement of primary health care through the study on the utilization rate of community health practitioner(CHP) post and its related factors toward some rural residents in Mooan County Chollanamdo, a questionnaire survey was made from 382 persons during August 1999. Comparison was made between persons at the seaside area under difficult transportation and persons at the railroad area under convenient transportation. The results are as follows: 1. For the last one year, 83.3% of seaside area residents and 67.0% of railroad area residents used CHP post. As the purpose of visit to CHP post at seaside area, 94.3% visited for medical care, 25.3% for chronic disease control and 22.2% for health counselling and 14.1% for chronic disease control. 2. By simple analysis, sex, age, marital status, educational level, residence area, distance from living village to CHP post, presence of chronic diseases, satisfaction with CHP and confidence on CHP were related significantly with the utilization of CHP post for the last one year. 3. By multiple logistic regression, statistically significant variables related with the utilization rate of CHP post for the last one year were analyzed as age, sex, residence area and distance from living village to CHP post.

  • PDF

Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model (골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구)

  • Kwon, Taek-Ka;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.128-137
    • /
    • 2011
  • Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

The Price-discovery of Korean Bond Markets by US Treasury Bond Markets by US Treasury Bond Markets - The Start-up of Korean Bond Valuation System - (한국 채권현물시장에 대한 미국 채권현물시장의 가격발견기능 연구 - 채권시가평가제도 도입 전후를 중심으로 -)

  • Hong, Chung-Hyo;Moon, Gyu-Hyun
    • The Korean Journal of Financial Management
    • /
    • v.21 no.2
    • /
    • pp.125-151
    • /
    • 2004
  • This study tests the price discovery from US Treasury bond markets to Korean bond markets using the daily returns of Korean bond data (CD, 3-year T-note, 5-year T-note, 5-year corporate note) and US treasury bond markets (3-month T-bill, 5-year T-note 10-year T-bond) from July 1, 1998 to December 31, 2003. For further research, we divide full data into two sub-samples on the basis of the start-up of bond valuation system in Korean bond market July 1, 2000, employing uni-variate AR(1)-GARCH(1,1)-M model. The main results are as follows. First the volatility spillover effects from US Treasury bond markets (3-month T-bill, 5-year T-note, 10-year T-bond) to Korean Treasury and Corporate bond markets (CD, 3-year T-note, 5-year T-note, 5-year corporate note) are significantly found at 1% confidence level. Second, the price discovery function from US bond markets to Korean bond markets in the sub-data of the pre-bond valuation system exists much stronger and more persistent than those of the post-bond valuation system. In particular, the role of 10-year T-bond compared with 3-month T-bill and 5-year T-note is outstanding. We imply these findings result from the international capital market integration which is accelerated by the broad opening of Korean capital market after 1997 Korean currency crisis and the development of telecommunication skill. In addition, these results are meaningful for bond investors who are in charge of capital asset pricing valuation, risk management, and international portfolio management.

  • PDF