• Title/Summary/Keyword: Cone-beam

검색결과 976건 처리시간 0.026초

한국인에서 3차원 conebeam CT를 이용한 부이공의 해부학적인 평가 (ANATOMICAL ASSESSMENT OF ACCESSORY MENTAL FORAMEN USING 3D CONE BEAM COMPUTED TOMOGRAPHY IN KOREAN)

  • 금기천;오승환;민승기;이병도;이종복;이대정;팽준영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권1호
    • /
    • pp.37-42
    • /
    • 2010
  • Purpose: The mental foramen (MF) is an important anatomical structure during local anesthesia and surgical procedures in terms of achieving effective mental nerve blocks and avoiding injuries to the neurovascular bundles. Thus, understanding the anatomic features of the mandibular canal and accessory mental foramen in Korean could contribute to the surgical anatomic assessment. This study was to elucidate frequency, position and course of AMF (accessory mental foramen) in Korean using 3D cone beam computed tomography. Materials and Methods: The CBCT (Conbeam computed tomography) DICOM data (Alphard, Asahi, Japan) from 540 patients in korean were analyzed. We investigated images of 3D CBCT using Ondemand (CyberMed, Korea) software program on the incidence and anatomical characteristics of accessory foramen. Results: The accessory mental foramina were found in 17 patients. Accessory mental foramina exist predominantly in the apical area of the second premolar and posteroinferior area of the mental foramen. The accessory branches of the mandibular canal showed common characteristics in the course of gently sloping posterosuperior direction in the buccal surface area. The size of most AMF was obviously smaller than that of MF. Conclusion: We could identify frequency, position and course of AMF (accessory mental foramen) by the anatomical study of the accessory mental foramen using 3D cone beam CT in Korean.

Three-dimensional evaluation of the relationship between nasopharyngeal airway shape and adenoid size in children

  • Oh, Kyung-Min;Kim, Min-Ah;Youn, Jong-Kuk;Cho, Hyung-Jun;Park, Yang-Ho
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.160-167
    • /
    • 2013
  • Objective: To evaluate the shapes and sizes of nasopharyngeal airways by using cone-beam computed tomography and to assess the relationship between nasopharyngeal airway shape and adenoid hypertrophy in children. Methods: Linear and cross-sectional measurements on frontal and sagittal cross-sections containing the most enlarged adenoids and nasopharyngeal airway volumes were obtained from cone-beam computed tomography scans of 64 healthy children ($11.0{\pm}1.8$ years), and the interrelationships of these measurements were evaluated. Results: On the basis of frontal section images, the subjects' nasopharyngeal airways were divided into the following 2 types: the broad and long type and the narrow and flat type. The nasopharyngeal airway sizes and volumes were smaller in subjects with narrow and flat airways than in those with broad and long airways (p < 0.01). Children who showed high adenoid-nasopharyngeal ratios on sagittal imaging, indicating moderate to severe adenoid hypertrophy, had the narrow and flat type nasopharyngeal airway (p < 0.01). Conclusions: Cone-beam computed tomography is a clinically simple, reliable, and noninvasive tool that can simultaneously visualize the entire structure and a cross section of the nasopharyngeal airway and help in measurement of adenoid size as well as airway volume in children with adenoid hypertrophy.

Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구 (Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms)

  • 권대근;민승기;전인철;팽준영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

Cone-beam CT에서 웨이브렛 역치값을 이용한 x-ray 영상에서의 노이즈 제거 (Noise Reduction of medical X-ray Image using Wavelet Threshold in Cone-beam CT)

  • 박종덕;허영;진승오;전성채
    • 전자공학회논문지SC
    • /
    • 제44권6호
    • /
    • pp.42-48
    • /
    • 2007
  • X-ray 영상 시스템에서는, 크게 2 종류의 noise 성분이 함유되어있다. 먼저 x-ray 방사선이 조사되어질 때, 검출기에서의 방사선의 상호작용으로부터 발생되어지는 것으로서 랜덤하게 발생되어지는 Poisson noise 성분이다. 다음으로 noise 성분은 readout electronics noise, pixel pattern noise 그리고 off-set noise 등으로부터 발생되어지는 Gaussian noise 성분이다. 그러나, x-ray 영상에서는 Gaussian noise가 아닌, Poisson noise로 모델링 되어진다. Gaussian noise에 의해서 발생되어지는 noise 성분은 위너필터 혹은 웨이브렛을 사용하여 쉽게 제거가 가능하지만, Poisson noise와 같은 랜덤 noise를 제거하기 위해서는 복잡한 분석기법이 필요하게 한다. 이 논문에서는 웨이브렛 영역에서 x-ray 영상의 Poisson noise를 제거하고자 하였으며, 적용된 분석 기법은 최적화된 웨이브렛 분석기법인 IBS(Improved BayesShrink)을 사용하였다. 적용된 IBS 기법은 cone-beam CT의 x-ray 영상에서의 기존의 방법에 비해 향상된 결과를 보여주었다.

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

제3대구치와 하악관과의 위치 관계에서 치과용 Cone beam CT의 유용성 (POSITIONAL RELATIONSHIP OF THE MANDIBULAR CANAL AND IMPACTED THIRD MOLARS BY USING DENTAL CONE BEAM COMPUTED TOMOGRAPHY)

  • 추연규;박영인;김진욱;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.492-498
    • /
    • 2009
  • We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

편측성 구순 구개열 환자의 하악 비대칭에 대한 cone-beam computed tomography를 이용한 평가 (Cone-beam computed tomography assessment of mandibular asymmetry in unilateral cleft lip and palate patients)

  • Veli, Ilknur;Uysal, Tancan;Ucar, Faruk Izzet;Eruz, Murat;Ozer, Torun
    • 대한치과교정학회지
    • /
    • 제41권6호
    • /
    • pp.431-439
    • /
    • 2011
  • Objective: To determine whether there is any difference between the cleft and non-cleft sides of the mandible in unilateral cleft lip and palate (UCLP) patients, or the right and left sides in control patients; and to determine if there is any difference between the mandibular asymmetry of UCLP patients and that of control patients. Methods: We examined cone-beam computed tomography (CBCT) scans of 15 patients with UCLP and 15 age- and gender-matched control patients. We evaluated 8 linear, 3 surface, and 3 volumetric measurements and compared the cleft/non-cleft sides of UCLP patients and the right/left sides of controls. Results: There were no statistically significant gender differences in any linear, surface, or volumetric measurement. The single significant side-to-side difference in UCLP patients was a longer coronoid unit on the cleft side than on the non-cleft side ($p$ = 0.046). Body volume was significantly lower in the UCLP group than in the control group ($p$ = 0.008). Conclusions: In general, UCLP patients have symmetrical mandibles, although the coronoid unit length is significantly longer on the cleft side than on the non-cleft side. UCLP patients and controls differed only in body volume.

Location and shape of the mandibular lingula: Comparison of skeletal class I and class III patients using panoramic radiography and cone-beam computed tomography

  • Jung, Yun-Hoa;Cho, Bong-Hae;Hwang, Jae Joon
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.185-190
    • /
    • 2018
  • Purpose: The aim of this study was to compare the location and the shape of the mandibular lingula in skeletal class I and III patients using panoramic radiography and cone-beam computed tomography. Materials and Methods: The sample group included 190 skeletal class I patients and 157 class III patients. The location of the lingula in relation to the deepest point of the coronoid notch was classified into 3 types using panoramic radiographs. The shapes of the lingulae were classified into nodular, triangular, truncated, or assimilated types using cone-beam computed tomographic images. The data were analyzed using the chi-square test. Results: The tips of the lingulae were at the same level as the coronoid notch in 75.3% of skeletal class I patients and above the coronoid notch in 66.6% of class III patients. The positions of the lingulae in relation to the deepest point of the coronoid notch showed statistically significant differences between class I and class III patients. The most common shape was nodular, and the least common was the assimilated shape. Although this trend was not statistically significant, the triangular shape was more frequently observed in class III patients than in class I patients. Conclusion: The locations and the shapes of the mandibular lingulae were variable. Most of the lingulae were at the same level as the coronoid notch in skeletal class I patients and above the coronoid notch in skeletal class III patients. The nodular and assimilated-shaped lingulae were the most and the least prevalent, respectively.

르포트씨 1급 골절단술을 시행 받은 환자들에서 Cone-beam Computed Tomography를 이용한 수술 전, 후의 상악동의 평가 (Evaluation of Maxillary Sinus Using Cone-beam Computed Tomography in Patients Who Underwent Le Fort I Osteotomy)

  • 이재열;김용일;백영재;황대석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권2호
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The aim of this sturdy was to assess the prevalence and change in pathologic findings in the maxillary sinus by using preoperative and postoperative cone-beam computed tomography (CBCT). Methods: The subjects included 83 patients with maxillary sinus abnormalities who underwent orthognathic surgery between January 2010 to December 2010. The CBCT analyses were classified according to the thickness of maxillary sinus membrane; Normal (membrane thickness<2 mm), mucosal thickening (membrane thickness ${\geq}2mm$ and <6 mm), partial opacification (membrane thickness>6 mm but not complete), total opacification, and polypoidal mucosal thickening. The diameters of the maxillary sinus ostium on the coronal cross-sectional view were also calculated. Results: Out of 166 maxillary sinuses in 83 patients, 42 (25.3%) maxillary sinuses before surgery and 37 (22.3%) maxillary sinuses after surgery showed abnormalities. A decrease in the diameters of maxillary ostium was observed after surgery (P<0.05). However, there was no significant difference in mucosal thickness both, preoperatively and postoperatively. Conclusion: The orthognathic surgery didn't deteriorate the maxillary sinus abnormaility. Despite the low prevalence of sinus complications in orthognathic surgery, all the patients should be informed of the possibility of sinusitis that could require the surgical intervention before surgery.