• Title/Summary/Keyword: Cone index

Search Result 201, Processing Time 0.019 seconds

Estimation of Undrained Shear Strength Using Piezocone Test (피에조 콘 시험을 이용한 점성토의 비배수 강도 추정)

  • 박용원;구남실;이상익
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.169-179
    • /
    • 2003
  • Undrained shear strength of clay deposit is one of the most important properties in the design of geotechnical structures. The use of piezocone test is rapidly growing due to its merit that can measure the in-situ undrained shear strength continuously with less error. The reliability of the shear strength from piezocone test depends upon the cone factor applied. Many researchers have suggested different ranges of values for the factors. This study performs to find out the validity of the suggested values in Korea and their charateristics related to the mechanical properties of clay. Piezocone tests were performed at the site of pilot project of ground improvement at Yangsan-Mulgeum Gyeongnam to investigate the charateristics of piezocone factors. The piezocone fators$(N_{kt}, N_{ke}, N_{\Delta u})$ based on the undrained shear strength from quick triaxial compression test are generally within the suggested range. And there appears considerable relations between undrained shear strength and $(N_{kt}, N_{ke}, N_{\Delta u})$ and between preconsolidation pressure and $(N_{kt}, N_{ke})$, while plasticity index, rigidity index and friction ratio do not show any relations with cone factors. The results also reveal that factor $(N_{\Delta u})$ shows higher reliability than factors $(N_{kt} and N_{ke})$, which show smaller standard deviation, breadth of change and scattering.

Determination of shear wave velocity profiles in soil deposit from seismic piezo-cone penetration test (탄성파 피에조콘 관입 시험을 통한 국내 퇴적 지반의 전단파 속도 결정)

  • Sun Chung Guk;Jung Gyungja;Jung Jong Hong;Kim Hong-Jong;Cho Sung-Min
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.125-153
    • /
    • 2005
  • It has been widely known that the seismic piezo-cone penetration test (SCPTU) is one of the most useful techniques for investigating the geotechnical characteristics including dynamic soil properties. As the practical applications in Korea, SCPTU was carried out at two sites in Busan and four sites in Incheon, which are mainly composed of alluvial or marine soil deposits. From the SCPTU waveform data obtained from the testing sites, the first arrival times of shear waves were and the corresponding time differences with depth were determined using the cross-over method, and the shear wave velocity profiles (VS) were derived based on the refracted ray path method based on Snell's law and similar to the trend of cone tip resistance (qt) profiles. In Incheon area, the testing depths of SCPTU were deeper than those of conventional down-hole seismic tests. Moreover, for the application of the conventional CPTU to earthquake engineering practices, the correlations between VS and CPTU data were deduced based on the SCPTU results. For the empirical evaluation of VS for all soils together with clays and sands which are classified unambiguously in this study by the soil behavior type classification Index (IC), the authors suggested the VS-CPTU data correlations expressed as a function of four parameters, qt, fs, $\sigma$, v0 and Bq, determined by multiple statistical regression modeling. Despite the incompatible strain levels of the down-hole seismic test during SCPTU and the conventional CPTU, it is shown that the VS-CPTU data correlations for all soils clays and sands suggested in this study is applicable to the preliminary estimation of VS for the Korean deposits and is more reliable than the previous correlations proposed by other researchers.

  • PDF

Evaluation of Smoke Risk and Smoke Risk Rating for Combustible Substances from Fire (화재로부터 연소성 물질에 대한 연기위험성 및 연기위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui;You, Ji Sun
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.197-204
    • /
    • 2021
  • This study investigated the smoke risk assessment of woods and plastics for construction materials, focusing on the smoke performance index-V (SPI-V), smoke growth index-V (SGI-V), and smoke risk index-VI (SRI-VI) according to a newly designed methodology. Spruce, Lauan, polymethylmethacrylate (PMMA), and polycarbonate (PC) were used for test pieces. Smoke characteristics of the materials were measured using a cone calorimeter (ISO 5660-1) equipment. The smoke performance index-V calculated after the combustion reaction was found to be 1.0 to 3.4 based on PMMA. Smoke risk by smoke performance index-V was increased in the order of PC, Spruce, Lauan and PMMA. Lauan and PMMA showed similar values. The smoke growth index-V was found to be 1.0 to 9.2 based on PMMA. Smoke risk by smoke growth index-V increased in the order of PMMA, PC, Spruce, and Lauan. COpeak production rates of all specimens were measured between 0.0021 to 0.0067 g/s. In conclusion, materials with a low smoke performance index-V and a high smoke growth index-V cause a high smoke risk from fire. Therefore, it is understood that the smoke risk from fire is high. It is collectively summarized by the smoke risk index-VI.

Evaluation of Piezocone Coefficient of Soft Grounds in the Areas of Gyeonggi and Incheon (경인지역 연약지반의 피에조콘계수 평가)

  • Park, Soo-Yong;Kim, Ki-Beom;Lee, Yun-Kyu;Baek, Seung-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.41-49
    • /
    • 2012
  • In this study, laboratory test, in-situ vane shear test and piezocone penetration test in the study area were conducted to investigate the engineering characteristics of soft soils at Cheongra District, Songdo District in Incheon City, the west coast of Gyeonggi province, and Sihwa District in Ansan city. The correlations among compression index, and in-situ vane shear test, and cone resistance were obtained. The variations of liquid limit, plasticity index, water content and compression index with respect to depth exhibit strong similarity. This means that they have strong correlations, which can be used to evaluate the local characteristics of the study area. Thus, the correlations between compression index and physical properties were analysed to investigate the engineering characteristics of soft soil in the study area. The relationships between the measured piezocone factor by empirical methods, and undrained shear strength obtained by triaxial compression test or in-situ vane shear test were compared. It shows the significant correlation and piezocone factors, $N_{kT}$are suggested for the study area.

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

Fire Resistance Study of PP Thermoplastic Composites with Particulate Reinforcements and Br Flame Retardants (무기 입자 강화제와 브롬(Br) 난연제에 따른 폴리프로필렌 복합재료의 난연성 향상에 관한 연구)

  • 곽성복;황성덕;남재도;고재송;최형기
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.260-269
    • /
    • 2002
  • The fire resistance of particulate polypropylene composite systems were investigated by using various reinforced particles such as zeolite, talc, $CaCO_3$ particles. In this study, The effect of particle size on the thermal properties of composite and the effect of reinforced particles on the fire resistance were studied. The inorganic reinforced particles used in this study were recycled zeolite(average particle diameter=85.34 $mu extrm{m}$), $CaCO_3$ (33.93 $mu extrm{m}$), and talc (18.51 $mu extrm{m}$). The fire resistance of composite systems was thoroughly examined by measuring limited oxygen index (LOI, ASTM D2863) and cone calorimetry (ASTM E1354, ISO 5660). Thermal stability of composite systems was thoroughly examined by measuring TGA. The flame retardants (DBDPO) and reinforced particles reduce the maximum heat release rate (M-HRR) in the order of Talc > $CaCO_3$ > recycled Zeolite. Comparing the cone calorimetry experimental results of the particle reinforced polymer composite system exhibited twice higher efficiency than DBDPO in polypropylene systems, and the LOI also showed similar trends to the cone calorimetry experiments. The optical and scanning electron microscopy techniques were used to investigate the composites ash layer and the core fracture surfaces in the burning process. The reinforcing inorganic particles seemed to accumulate at the surface of ash layer, and subsequently intercept the oxygen transport and heat transfer into the core area.

A Research on the Brassiere Preference and Wearing Status of Chinese Women in their 20's (중국 20대 전반 여성의 브래지어 착용실태 및 선호도 연구)

  • Cha, Su-Joung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.12 no.2
    • /
    • pp.72-86
    • /
    • 2008
  • This research focused on determining the brassiere preference index and wearing status of chinese ladies in their 20's living in the Shanghai region of China, to help Korean lingerie companies in their development of bras to successfully advance into the Chinese lingerie market. The main research tool of this research was various different surveys, and the results of the surveys were evaluated using the SPSS 12.0 for Window program. The results of the survey can be summarized as: 1) consciousness and satisfaction level of the body. The satisfaction level of the brest was proportionate to the size of the brassiere, thus, people showed higher level of satisfaction for cone-shaped, semi-circular shaped, prominent-shaped(exposing), lifted-shaped brest over flat-shaped brest. Concerning the relationship between the shape of the brest and the age of the customers, people under 22 years of age preferred flat-shaped, and those between 23-24 years of age preferring exposing and lifted brest, thus as females mature and get older, the size of their brest increases, thus having preference on more circular and lifted-shaped brest and bras. 2) Status of bra wearing in China When we look at the size of the bra in relation to the shape of the brest, those classified as having 'flat-shaped' brest showed a high proportion of A-cups, ranging from 75A, 70A and 80A, where as those of 'cone-shaped' brest represented high ration of B-cups, ranging from 75B, 75A and 80B. Majority of those classified as having 'semi-circular shaped' and 'prominent-shaped(exposing)' brest showed a high ration in the size 80 range. And vast majority of those classified into the 'lifted-shaped' brest group, were reported of having C-cup size bras. 3) Status of Bra Purchasing As people mature, the main reason behind choosing a bra was the actual design of the bra, where they emphasized the importance of aesthetic values. People classified as having 'flat-shaped' and 'cone-shaped' brest emphasized the importance of design and beauty, while those having 'semi-circular shaped,' 'prominent-shaped(exposing),' and 'liftedshaped' brest groups emphasized the importance of hygiene and the material(fabric) of the bra. This shows that when people have relatively smaller brest, they emphasize the importance of external appearance whereas when the size of the brest increases, they pay more attention to the function of the bra rather than the external appearance.

Fire Risk Index and Grade Evaluation of Combustible Materials by the New Chung's Equation-XII (새로운 Chung's equation-XII에 의한 연소성 물질의 화재위험성지수 및 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.388-396
    • /
    • 2023
  • The evaluation of fire risk for combustible materials was carried out using Chung's equations-X, Chung's equations-XI, and Chung's equation-XII, which were newly established. The fire risk index-XII (FRI-XII) and fire risk rating (FRR) were calculated for specimens including camphor tree, cherry, rubber tree, and elm. The combustion characteristics were determined using a cone calorimeter according to ISO 5660-1. Chung's equations caculated the fire performance index-X (FPI-X) and fire growth index-X (FGI-X) values ranged from 89.34 to 1696.75 s2 /kW and from 0.0006 to 0.0107 kW/s2 , respectively. In addition, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) varied from 0.08 to 1.48 and from 0.67 to 11.89, respectively. The fire risk index-XII (FRI-XII), which is an indicator of fire risk, showed that camphor tree had a value of 148.63 (fire risk rating: G), indicating a very high fire risk. This suggests that combustible materials with a high concentration of volatile organic compounds have lower FPI-X and FPI-XI values, higher FGI-X and FGI-XI values, and consequently higher FRI-XII values, indicating an increased fire risk.

Assessment of Smoke Risk of Combustible Materials in Fire (화재 시 가연성 물질의 연기 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • The smoke hazard assessment of building materials focusing on smoke performance index-II (SPI-II) and smoke growth index-II (SGI-II) was investigated. The test species used were Japanese cedar, spruce, lauan, and red pine. The smoke characteristics of wood specimen were investigated using a cone calorimeter (ISO 5660-1). SPI-II was measured after the combustion reaction increased by 1.31~2.15 times based on red pine. The fire risk by SPI-II increased in the order of spruce, lauan, Japanese ceda, and red pine. SGI-II increased by 1.18~2.55 times compared to that of Japnese ceda. The fire risk caused by SGI-II increased in the order of Japanese ceda, spruce, lauan, and red pine. COmean concentrations were ranged from 58 to 133 ppm, which was higher than permissible exposure limits of the occupational safety and health administration (OSHA), 50 ppm. Therefore, woods such as red pine containing various volatile organic substances, were considered to be highly smoke hazardous due to low SPI-II and high SGI-II.

Fire Risk of Wood Treated With Boron Compounds by Combustion Test (연소시험에 의한 붕소 화합물 처리 목재의 화재위험성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.19-26
    • /
    • 2018
  • Experiments on the combustion characteristics of untreated wood specimens and also treated ones with boric acid and ammonium pentaborate were carried out using a cone calorimeter according to ISO 5660-1 standard. As a result, comparing to untreated specimen, the fire performance index (FPI) of the specimens treated with boron compounds increased by 1.2 to 2.1 times and the fire growth index (FGI) increased by 1.6 to 8.4%. Also, total smoke release rate (TSR) was 9.0 to 28.3% lower than that of the untreated specimen. It is understood that the test specimens treated with the boron compound produces a carbonized layer with a flame retarding effect. The highest CO concentration, 0.01112%, for the untreated specimen was observed at 418 s, but the specimens treated with boron compound decreased 13.2 to 37.5% compared to untreated specimen. Therefore, wood treated with boron compounds is expected to have lower fire hazards and risks.