• Title/Summary/Keyword: Conduction Velocity

Search Result 239, Processing Time 0.024 seconds

Effect of Joule Heating Variation on Phonon Heat Flow in Thin Film Transistor (줄 가열 변화에 따른 박막 트랜지스터 내 포논 열 흐름에 대한 수치적 연구)

  • Jin, Jae-Sik;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.820-826
    • /
    • 2009
  • The anisotropic phonon conductions with varying Joule heating rate of the silicon film in Silicon-on-Insulator devices are examined using the electron-phonon interaction model. It is found that the phonon heat transfer rate at each boundary of Si-layer has a strong dependence on the heating power rate. And the phonon flow decreases when the temperature gradient has a sharp change within extremely short length scales such as phonon mean free path. Thus the heat generated in the hot spot region is removed primarily by heat conduction through Si-layer at the higher Joule heating level and the phonon nonlocality is mainly attributed to lower group velocity phonons as remarkably dissimilar to the case of electrons in laser heated plasmas. To validate these observations the modified phonon nonlocal model considering complete phonon dispersion relations is introduced as a correct form of the conventional theory. We also reveal that the relation between the phonon heat deposition time from the hot spot region and the relaxation time in Si-layer can be used to estimate the intrinsic thermal resistance in the parallel heat flow direction as Joule heating level varies.

Multiple Brain Calcification in Chronic Lead Poisoning (만성 연중독자에서의 다발성 뇌석회화 병변)

  • Kim, Sung-Ryul;Kim, Byoung-Gwon;Hong, Young-Seoub;Dam, Do-Won;Choi, Soon-Seob;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.398-405
    • /
    • 1995
  • We experienced a case of occupational lead poisoning employed in a secondary lead smelting plant for 12 years. The patient was 39-year-old male and had been felt dizziness, recent memory impairment and intermittent severe abdominal pain for 2 years. On admission, blood lead level was $92.9{\mu}g/dl$, urinary lead level was $19.9{\mu}g/l$ and zinc protoporphyrin level was $226.0{\mu}g/dl$. On the blood test, hemoglobin was 10.6g/dl and showed normocytic normochromic anemia. There were no abnormal findings in the biochemical and hormonal tests. Decrease of I.Q. and use of words in speaking were found in the psychiatric and psychologic examinations. We observed the finding of motor polyneuropathy in the nerve conduction velocity test. Computed tomographic finding showed calcification lesions in the basal ganglia, dentate nuclei, caudate nuclei, and especially characteristic multiple calcifications were located in the subcortical white matter.

  • PDF

Simulation of Temperature Changes of Rough Rice Stored in Round Steel Bin (I) - Development of a Simulation Model - (시뮬레이션에 의한 저장 벼의 곡온 예측)

  • Keum D.H.;Kim J.Y.;Kim H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.355-362
    • /
    • 2006
  • A one-dimensional heat conduction problem in cylindrical coordinate system was solved using Crank-Nicolson finite difference method to predicting the temperature distribution in rice storage bin with wall insulator. The model can simulate the grain temperatures in insulated round bins using the input data of initial grain temperature. ambient air temperature, wind velocity, solar radiation on a horizontal surface, and thermal properties of grain, bin wall, wall insulator, insulator cover, and air. Temperatures were collected at the bin center, 0.65m in radial direction from the center, and near the bin wall in 2.7m diameter bin filled with rough rice to depth of 3.0m were used to validate the simulation model. Grain temperatures predicted by the model were in very good agreement with the measured temperatures. The residual mean square error between measured and predicted grain temperatures at the bin center was $1.38^{\circ}C$.

Relationship between Endurance Times and Frequency Parameters in Surface EMG during Isotonic Contraction Exercises (등장성 수축운동시 표피근전도의 주파수파라미터와 근지구력시간과의 상관성)

  • Lee, Sangsik;Go, Jaewook;Jang, Jeehun;Park, Wonyeop;Lee, Kiyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.135-140
    • /
    • 2012
  • Previous investigators have shown that the frequency compression is related to the muscle fatigue and the decreasing conduction velocity of muscle fibers. The aim of the present study was to investigate the relationship between endurance times and frequency parameters such as mean power frequency and median frequency in the surface EMG signal during isotonic contractions. Eight healthy subjects performed voluntary isotonic contractions of biceps Brachii muscle until their endurance times which were determined when the subject could no longer follow the contraction cycle. The regressive slopes of mean power frequency and median frequency were used to describe the frequency compression of the surface EMG signal, and to test the predictability of endurance time. As results of experiment, significant correlations were found between endurance time and the regressive slopes of mean power frequency and mean frequency computed over 50%Tend of endurance time.

An experimental study of frost forming on the horizontal cylinder under cross flow (직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구)

  • 이윤빈;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

Effects of Droplet Temperature on Heat Transfer During Collision on a Heated Wall Above the Leidenfrost Temperature (Leidenfrost 온도 이상의 가열 벽면과 충돌 시 열전달에 대한 액적 온도의 영향)

  • Park, Junseok;Kim, Hyungdae
    • Journal of ILASS-Korea
    • /
    • v.21 no.2
    • /
    • pp.78-87
    • /
    • 2016
  • This study experimentally investigated the effects of droplet temperature on the heat transfer characteristics during collision of a single droplet on a heated wall above the Leidenfrost temperature. Experiments were performed by varying temperature from 40 to $100^{\circ}C$ while the collision velocity and wall temperature were maintained constant at 0.7 m/s at $500^{\circ}C$, respectively. Evolution of temperature distribution at the droplet-wall interface as well as collision dynamics of the droplet were simultaneously recorded using synchronized high-speed video and infrared cameras. The local heat flux distribution at the collision surface was deduced using the measured temperature distribution data. Various physical parameters, including residence time, local heat flux distribution, heat transfer rate, heat transfer effectiveness and vapor film thickness, were measured from the visualization data. The results showed that increase in droplet temperature reduces the residence time and increases the vapor film thickness. This ultimately results in reduction in the total heat transfer by conduction through the vapor film during droplet-wall collision.

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance (기준전극의 형상과 입력전극사이의 간격을 고려한 건식형 표면 근전위 센서 개발)

  • Choi, Gi-Won;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.550-557
    • /
    • 2006
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

A study of thermophoretic particle deposition in a particle laden stagnation flow including the effect of radiative heat transfer (정체점 입자유동에서 복사열전달을 고려한 열영동 입자부착 연구)

  • Jeong, Chang-Hun;Lee, Gong-Hun;Choe, Man-Su;Lee, Jun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1624-1638
    • /
    • 1996
  • A study of thermophoretic particle deposition has been carried out for a particle laden stagnation flow considering the effect of radiative heat transfer. Energy, concentration and radiative transfer equations are all coupled and have been solved iteratively assuming that absorption and scattering coefficients were proportional to the local concentration of particles. Radiative heat transfer was shown to strongly affect the profiles of temperature and particle concentration. e. g., radiation increases the thickness of thermal boundary layer and wall temperature gradients significantly. As the wall temperature gradients increase, the particle concentration at the wall decreases due to thermophoretic particle transport. The deposition rate that is thermophoretic velocity times particle concentration at the wall decreases as the effects of radiation increases. The effects of optical thickness, conduction to radiation parameter and wall emissivity have been determined. The effects of anisotropic scattering are shown as insignificant.

Cooling Performance of LED Head Lamp with Heat Sink and Cooling Fan (팬과 히트 싱크를 이용한 LED 전조등의 냉각성능 해석)

  • Ko, Man-Seok;Lee, Ju-Han;Oh, Sang-June;Cho, Hyen-Seok;Seo, Tea-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.12
    • /
    • pp.947-951
    • /
    • 2009
  • LED has the merits of high reliability, semi-permanent life, rapid-response and its small size for use as light source of head lamp. But the dependence of its performance and life on temperature affect on its practical use. Which dependence makes problem when the LED is heated up to a higher temperature level by self-generation of heat, due to "highly integration" to get enough quantity of light. To solve this problem, effective cooling system is needed that consider conduction, convection and radiation. This study points out the limits of natural convection cooling system and propose of forced convection with heat sink. Also, it describes a correlation between heat sink area and fluid velocity using numerical analysis to optimize the cooling system.

Extraction of Hydrodynamic Model Parameters for GaAs Using the Monte Carlo Method (Monte Carlo Method에 의한 GaAs의 Hydrodynamic Model Parameter의 추출)

  • Park, Seong-Ho;Han, Baik-Hyung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.3
    • /
    • pp.63-71
    • /
    • 1990
  • The hydrodynamic model parameters for the submicron GaAs simulation are calculated using the Monte Carlo method. $\Gamma$, L-, and X-valleys are included in the conduction band of GaAs, and polar optic phonon, acoustic phonon, equivalent intervalley, non-equivalent intervalley, ionized impurity, and piezoelectric scattering are taken into account. The velocity-electric field strength curve obtained in this paper is in good agreement with experimental one. We present the results in tabular form so that other participants can make use of them to simulate the submicron GaAs devices by the hydrodynamic model.

  • PDF