Browse > Article

Development of Dry-type Surface Myoelectric Sensor for the Shape of the Reference Electrode and the Inter-Electrode Distance  

Choi, Gi-Won (재활공학연구소)
Choe, Gyu-Ha (건국대 전기공학과)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers D / v.55, no.12, 2006 , pp. 550-557 More about this Journal
Abstract
This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper is proposed two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value(MAV) circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.
Keywords
surface myoelectric sensor; myoelectric hand prosthesis; electrode shape; inter-electrode distance;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 D. Farina and R. Merletti, 'A novel approach for estimating muscle fiber conduction velocity by spatial and temporal filtering of surface EMG signals,' IEEE Trans. Biomed. Eng., vol. 50, No. 12, pp. 1340-1351, December 2003   DOI   ScienceOn
2 K. Englehart and B. Hudgins, 'A robust, real-time control scheme for multifunction myoelectric control,' IEEE Trans. Biomed. Eng., vol. 50, No.7, pp. 848-854, July 2003   DOI   ScienceOn
3 최기원, 문인혁, 이명준, 추준욱, 문무성 '전극형상에 따른 건식형 능동 표면 근전도 전극의 성능 평가' 제29회 대한의용생체공학회 추계학술대회, 2003
4 양덕진, 전창익, 이영석, 이진, 김성환, '공간필터에 의한 운동단위 활동전위의 분해능 향상에 관한 연구' 대한전기학회논문지D, vol. 53, pp 55-64, 2004   과학기술학회마을
5 D.K. Kumar and A. Melaku, 'Electrode Distance and magnitude of SEMG,' Proc. of the Second Joint EMBS/BMES Conf., vol. 3, pp, 2477-2480, October 2002
6 C.J. Luca, 'Physiology and Mathematics of Myoelectric Signals,' IEEE Trans. Biomed. Eng., vol. 26, No.6, 1979   DOI   ScienceOn
7 H. Nicolai, L. Teodorsscu, L. C. Jain 'Intelligent systems and technologies in rehabilitation engineering.' CRC press, pp.243-246, 2001
8 한국보건사회연구원, 2000년 전국 장애인 추정치, 2001
9 http://www.ottobockus.com
10 D.J. Hewson, J. Duchene and J.Y. Hogrel, 'Changes in impedance at the electrode-skin interface of surface EMG electrodes during long-term EMG recordings,' Proc. of the 23rd Annual EMBS Int'l Conf., pp. 3345-3348, 2001   DOI
11 P. J. Kyberd, C. L.ight, P. H. Chappell, J. M. Nightingale, D. Whatley and Mervyn Evans,' The design of anthropomorphic prosthetic hands: A study of the Southampton Hand'. Robotica, vol. 19, pp.593-600, 2001   DOI   ScienceOn
12 http://www.utaharm.com
13 P. Karnpas, 'The optimal use of myoelectrodes,' http://www.ottobockus.com/ASSETS/9C5BFB5A32664A7EB45869D7EB51E773/Kampas%20Electrode%20Article.pdf
14 http://www.imasen.co.jp/welfare_lapoc.html
15 http://www.delsys.com
16 http://www.emgsrus.com