• 제목/요약/키워드: Conductance stability

검색결과 34건 처리시간 0.027초

Field Emission Display의 고진공 실장에 관한 연구 (Study on Vacuum Packaging of Field Emission Display)

  • 이덕중;주병권;장진;오명환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.103-106
    • /
    • 1999
  • In this paper, we suggest the FED packaging technology that have 4mm thickness, using sodalime glass-to-sodalime glass electrostatic bonding. It based on conventional silicon-glass bonding. The silicon film was deposited an around the exhausting hole on FED backside panel. And then, the silicon film of panel was successfully bonded with capping(bare) glass in vacuum environment and the FED panel was vacuum-sealed. In this method, we could achieve more 153 times increased conductance and 200 times increased vacuum efficiency than conventional tube packaging method. The vacuum level in panel, by SRG test, was maintained about low 10$_{-4}$ Torr during above two months And, the light emission was observed to 0.7-inch tubeless packaged FED. Then anode current was 34 $\mu$ A. Emission stability was constantly measured for 10 days.

  • PDF

고강도 전자소자 리드프레임용 Cu/STS/Cu 클래드 메탈제조 및 물리적특성에 대한 열안정성 연구 (Fabrication of the Cu-STS-Cu Clad Metal for High Strength Electric Device Lead Frame and Thermal Stability on Their Physical Properties)

  • 김일권;손문의;김용성
    • Journal of Welding and Joining
    • /
    • 제32권5호
    • /
    • pp.80-86
    • /
    • 2014
  • We have successfully fabricated high strengthening Cu/STS/Cu 3 layered clad metal of $70kgf/mm^2$ grade for electric device lead frame, and investigated thermal effect of the mechanical and physical properties on the Cu/STS/Cu 3 layered clad metal lead frame material at different temperatures ranging from RT to $200^{\circ}C$. The fabricated clad metal shows a good thermal stability under 6% degrading of mechanical tensile strength and hardness change at $200^{\circ}C$ and also physical properties show stable thermal and electrical conductance of over $220W/m{\cdot}K$ and 58.44% IACS upto the $200^{\circ}$. The results confirm that fabricated high strengthening Cu/STS/Cu 3 layered clad metal can be applied for the high performed electrical lead frame devices.

전력 트랜지스터의 특성에 미치는 다이아몬드상 카본 passivation 막의 효과 (Effect of diamond-like carbon film as passivation layer on characteristics of power transistor)

  • 박정호;임대순;정석구;장훈;신종한
    • 전자공학회논문지A
    • /
    • 제33A권11호
    • /
    • pp.97-104
    • /
    • 1996
  • Because of the novel characteristics such as chemical stability, hardness, electrical resistivity and thermal conductance, diamond-like carbon (DLC) film is a suitable materials for the passivation layers. For this purpose, DLC films are synthesized under various conditions and are characterized. Adhesive stregth is excellent and increased with the increase of the hydrogen gas flow rate. The resistivity of approximately 5.3X10$^{8}{\Omega}{\cdot}cm$ is measured by automatic spreading resistance probe analysis method. The thermal conductivity of DLC films is superior to that of PSG oxide and improved by increasing the hydrogen gas flow rate. The patterning techniques of the DLC films is developed using the lift-off and RIE methods to form 5${\mu}$m line. Finally, power transistor with the DLC film as passivation layer is fabricated and analyzed. The test result shows the improsved long-term stability and higher breakdown voltage.

  • PDF

스퍼터 증착된 Zinc Tin Oxide 박막 트랜지스터의 공정 압력에 따른 특성 연구 (The Properties of RF Sputtered Zinc Tin Oxide Thin Film Transistors at Different Sputtering Pressure)

  • 이홍우;양봉섭;오승하;김윤장;김형준
    • 반도체디스플레이기술학회지
    • /
    • 제13권1호
    • /
    • pp.43-49
    • /
    • 2014
  • Zinc-tin oxides (ZTO) thin film transistors have been fabricated at different process pressure via re sputtering technique. TFT properties were improved by depositing channel layers at lower pressure. From the analysis of TFTs comprised of multi layer channel, deposited consecutively at different sputtering pressure, it was suggested that the electrical characteristics of TFTs were mainly affected by interfacial layer due to their high conductance, however, the stability under the NBIS condition was influenced by whole bulk layer due to low concentration of positive charges, which might be generated by the oxygen vacancy transition, from Vo0 to $Vo^{2+}$. Those improvements were attributed to increasing sputtered target atoms and decreasing harmful effects of oxygen molecules by adopting low sputtering pressure condition.

퍼지제어에 의한 PV시스템의 PCS 출력특성 (PCS Power Characteristics of PV System by Fuzzy Controller)

  • 문은아;임흥우;백형래;조금배;오금곤;임양수;김평호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.147-150
    • /
    • 2004
  • Maximum power point tracking for PV systems traditionally uses either perturbation and observation method or incremental conductance method. Both methods require modulation of the output voltage and this leads to significant power loss. In this paper, a method, which senses output circuit voltage and short circuit current and use the above two parameters for optimum control with a fuzzy controller, is introduced. The short circuit current of PV cell represents illumination, and the output circuit voltage carry on information about the temperature. PCS(power conditioning system) is controlled not only feed to inverter for stability voltage variation despite of variety external environment, but also operate in order to feeding voltage and current at maximum power point by boost type chopper.

  • PDF

CuTBT(Copper-tetra-tert-buthylphthalocyanine) LB막의 Chemiresistor Device 특성에 관한 연구 (A Study on the Chemiresistor Device characteristics of the CuTBP(Copper-tetra -tert-buthylphthalocyanine) LB films)

  • 이창희;구자룡;김태완;김정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.6.2-8
    • /
    • 1996
  • The NO$_2$ GAS-detection characteristic of CuTBT (Copper-tetra-tert-butylphtha1ocyanine) LB films were investigated through a study of current-voltage (I-V) characteristics with a variation of number N of interdigital electrodes (N=1∼25). A concentration of 200ppm NO$_2$ gas was used. It was found that a conductance G increases monotonically as the number of interdigital electrode increases, and a sensitivity $\Delta$G ($\Delta$G=G$\_$gas//G$\_$air/) is at least higher than 50 and stable. As far as a sensitivity is concerned, the sensitivity when N=26 is greater than that when N=1 by 70 or so. It indicates that the number of interdigital electrodes affects the currents, sensitivity and stability.

CuTBP(Copper-tetra-tert-butylphthalocyanine) 화학 저항 장치를 이용한 NO$_2$ 가스 탐지기의 개발에 관한 연구 (A study on the NO$_2$ gas detector development using the CuTBP (Copper-tetra-te rt-butylphthalocyanine) chemiresistor device)

  • 구자룡;이창희;김태완;김정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.417-420
    • /
    • 1996
  • We have investigated air/200ppm NO$_2$ gas-detector characteristics of using CuTBP (Copper-tetra-tert-butylphthalocyanine) chemiresistor devices. The CuTBP films were made by Langmuir-Blodgett (LB) techniques. Sensitivity, response time, recovery time, and repoducibility of the devices were measured by current-voltage characteristics. To increase sensitivity, interdigital electrode was used. It was found that a conductance G increases monotonically as the number of interdigital electrode increases, and a Sensitivity, Reproducibility is stable. As far as a current is concerned, the current when N=25 is greater than that when N=1 by 70 or so. It indicates that the number of interdigital electrodes affects the current, sensitivity and stability We have also investigated applicability of the CuTBP chemiresistor device for a gas detector.

  • PDF

벡터 곱에 근거한 에너지함수 유도와 선로 컨덕턴스 및 커패시터를 포함한 전력시스템에의 적용 연구 (Derivation of an Energy Function Based on Vector Product and Application to the Power System with Transfer Conductances and Capacitors)

  • 문영현;오용택;이병하
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.274-283
    • /
    • 2005
  • This paper presents a new method to derive energy function based on vector product. Using this method, an energy function to consider transfer conductances and capacitors is derived. Then we recommend a voltage collapse criteria to predict the voltage collapse in power systems by using the energy margin derived by the proposed energy function. This energy function is applied to a 2-bus power system reflecting transfer conductances and capacitors. We show that the energy function derived based on vector product can be applied in order to analyze power system stability and the energy margin can be utilized as a criterion of voltage collapse by simulation for the 2-bus system.

Synthesis, Characterization and Spectrophotometric Studies of Seven Novel Antibacterial Hydrophilic Iron(II) Schiff Base Amino Acid Complexes

  • Shaker, Ali M.;Nassr, Lobna A.E.;Adam, Mohamed S.S.;Mohamed, Ibrahim M.A.
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.560-567
    • /
    • 2013
  • A series of new Iron(II) Schiff base amino acid complexes derived from the condensation of amino acid and sodium 2-hydroxybenzaldehyde-5-sulfonate have been synthesized. The complexes were characterized by elemental, electronic, IR spectral analyses and conductance measurements. The stability and solubility of the prepared complexes were determined. Two spectral methods used to determine the stoichiometry of the prepared complexes which exhibited divalent tridentate coordination and formed chelates of octahedral structures. The antibacterial activity of the prepared complexes has been tested against Bacillus cereus, Pseudomonas aeruginosa and Micrococcus bacteria. The effect of HCl on investigated complexes studied spectrophotometrically.

지하 원유 저장공동에서의 누수량 산정에 대한 연구 (Estimation of Water Leak Rate in the Underground Oil Storage Cavern)

  • 심현진;박태준;정우철;김호영;최영태
    • 터널과지하공간
    • /
    • 제20권4호
    • /
    • pp.233-240
    • /
    • 2010
  • 지하 원유 저장공동에서 두 공동간의 혼유 방지를 위해 설치되는 더블 플러그는 구조물 시공 후 더블 플러그 내부를 물로 채운 후에 충수의 누수 정도를 파악함으로써 플러그 기밀성을 평가한다. 만약 예상 누수량이 과소하게 산정되면 시공비용이 증대되고, 과다하게 산정될 경우에는 운영비용이 증가될 수 있으므로 최적의 예상 누수량을 산정할 필요가 있다. 본 연구에서는 더블 플러그(double plug) 주변의 투수특성을 보다 정확하게 반영할 수 있도록 수리 안정성 해석을 수행하였으며, 수리 안정성 해석 및 기존 사례 분석 과정을 통해 플러그 주변의 누수 가능성이 있는 모든 경로에 대한 예상 누수량을 산정하였다. 또한 누수 경로에 대한 누수량을 실측 하여 예상 누수량 산정 결과의 신뢰성을 확인하였다.