THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS (수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구)

  • Yu Seong-Hyun;Park Won-Hee;Park Ju-Jin;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.

A Case of Juvenile Glomerulonephropathy in a Cocker Spaniel Dog (어린 cocker spaniel 종에서 발생한 신부전증)

  • Kwon, O-Serng;Yi, Jung-Yeon;Kwak, Ho-Hyun;Woo, Heung-Myung;Han, Jeong-Hee;Yoon, Byung-Il
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.647-652
    • /
    • 2007
  • In the present study, we address systemically a case of renal disease developed in a 1 year-old male cocker spaniel dog in terms of clinical signs, clinical pathology and pathological examinations. The animal has been suffered from renal dysfunction signs such as polyuria, anorexia, vomiting, diarrhea and weight loss. The dog was very weak and emaciated and had foamy contents with foul-smell in oral cavity. The animals showed notable decrease in the number of red blood cells and severe decreases of hemoglobin and hematocrit with or without changes of mean corpuscular volume and mean corpuscular hemoglobin concentration values, indicating microcytic or normocytic hypochromatic anemia. In serum chemistry, blood urea nitrogen, creatinine, phosphorous, Na and Cl, which are associated with renal function, were dramatically increased. In addition, alanine aminotransferase, aspartate transferase, alkaline phosphatase, cholesterol, lipase and amylase were also significantly elevated, while K concentration was notably decreased. Urinalysis indicated prominent proteinuria with increase of bilirubin. Despite of symptomatic treatments, the dog was getting worse in healthy condition and dead in the end. At necropsy, both kidneys were brownish, pale, slightly small, and have diffuse, firm and subcapsular pits. Histologically, the kidneys indicated prominent segmental or diffuse interstitial fibrosis in cortex and medulla as well as glomerulonephritis. The clinical signs, clinical pathology and histopathological abnormalities of the young dog presented were consistent with chronic glomerulonephropathy, which was suspected to be a case of familial renal disease in the juvenile cocker spaniel dog.

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

A Literature Review and Analysis of Dosimetry in Panoramic Radiography (파노라마 촬영의 피폭선량에 관한 문헌분석 연구)

  • Kweon, Dae-Cheol;Dong, Kyung-Rae;Jung, Jae-Eun;Lee, Kyeong-Hee;Kim, Soo-Kyung;Kim, Wook-Tae;Lee, Cheong-Jae;Song, Woon-Heung;Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Dental panoramic radiography is an imaging technique which shows the information of teeth, jaws and superficial structures on a single image. In this study, we propose the clinical dose reference for dental panoramic radiography. Dental panoramic radiography is an application which can increase the radiation does of oral cavity. It is very important to study the real condition of management for these panoramic X-ray equipments. Since there was no researches on dental panoramic equipments in domestic and foreign study groups, we measured and analyzed the dose such as effective dose, DAP and DWP of panoramic radiography.

A Case of Bilateral Pneumoparotid Improved with Conservative Treatment (보존적 치료로 호전된 양측 이하선 기종 1예)

  • Oh, Yun Seok;Kim, Jeong Marn;Jung, Hahn Jin;Shim, Woo Sub
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.1
    • /
    • pp.43-45
    • /
    • 2017
  • Pneumoparotid is defined as the presence of air within the parotid gland or duct. Pneumoparotid is an extremely rare cause of parotid gland swelling. Pneumoparotid can be induced by air insufflation from oral cavity into the intraparotid salivary ducts, in condition like nose blowing, blowing up balloons, during extubation after general anesthesia while receiving positive pressure, rapid decompression while scuba diving, chronic attempts to suppress cough, and glassblowers. It can also be self-induced, and the literature contains an increasing number of reports involving pediatric and adolescent patients who induce parotid insufflation to avoid school or gain attention. Here, we report a case of pneumoparotid caused by habitual cheek inflating and improved with conservative treatment.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Comparative Study of the Ablation Rates of Er: YAG Laser Irradiation on Dentin and Enamel (Er:YAG 레이저를 이용한 법랑질과 상아질의 절삭율 연구)

  • Kim, Kun-A;Ahn, Yong-Woo;Ko, Myung-Yun;Park, June-Sang
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.131-140
    • /
    • 2005
  • The purpose of this study was to examine the ablation rate of Er: YAG laser irradiation on dentin and enamel and to observe the microscopic structures of cavities formed after ablation of enamel and dentin in using a bur and cavities formed after ablation using laser. Er:YAG laser irradiated at 200 mJ, 250mJ, 300mJ at the frequency of 20Hz, 15Hz. The following results were obtained : 1. The ablation rate of dentin groups at power of 3 W-6 W was about $1.103{\sim}2.639mm^3/sec$ and there were no significant differences between power of 4.5 W$\sim$6 W. 2. The ablation rate of enamel groups at power of 3 W-6 W was about $0.413{\sim}0.969mm^3/sec$ and there were no significant differences between power of 4 W$\sim$6 W. 3. With SEM examination of the cavity surface treated with the conventional high speed bur revealed relatively flat appearance almost covered with a debris like smear layer. 4. With SEM examination of the lased surface of dentin groups revealed no smear layer and no debris and openings of dentinal tubules were clearly opened. But the lased surfaces of the groups over 3 W were irregular and particles were loosely attached on it. 5. With SEM examination of the lased surface of enamel groups revealed severely destructed surface at the 6 W group and melting drop materials at the 3 W group. But the lased surface of 4 W group revealed clearly ablated surface. Therefore when cutting teeth using Er:YAG laser, the lasing power which can make effective ablation rate and minimize the thermal effect could be 3W at dentin and 4W at enamel. But, further studies and additional data collection will be necessary for appropriate lasing condition of Er:YAG laser.

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo (다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석)

  • Yu, Jin-Kyoung;Ahn, Sug-Joon;Lee, Shin-Jae;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.105-111
    • /
    • 2009
  • Objective: To estimate the effects of bracket material type on enamel decalcification during orthodontic treatment, this study analyzed the adhesion level of mutans streptococci (MS) to orthodontic bracket materials in vivo. Methods: Three different types of orthodontic bracket materials were used: stainless steel, monocrystalline sapphire, and polycrystalline alumina. A balanced complete block design was used to exclude the effect of positional variation of bracket materials in the oral cavity. Three types of plastic individual trays were made and one subject placed the tray in the mouth for 12 hours. Then, the attached bacteria were isolated and incubated on a mitis salivarius media containing bacitracin for 48 hours. Finally, the number of colony forming units of MS was counted. The experiments were independently performed 5 times with each of the 3 trays, resulting in a total of 15 times. Mixed model ANOVA was used to compare the adhesion amount of MS. Results: There was no difference in colony forming units among the bracket materials irrespective of jaw and tooth position. Conclusions: This study suggested that the result of quantitative analysis of MS adhesion to various orthodontic bracket materials in vivo may differ from that of the condition in vitro.