Browse > Article

A Literature Review and Analysis of Dosimetry in Panoramic Radiography  

Kweon, Dae-Cheol (Department of Radiologic Science, Shin Heung College University)
Dong, Kyung-Rae (Department of Radiological Technology, Gwangju Health College University)
Jung, Jae-Eun (Department of Digital Management and Information, Graduate School, Nambu University)
Lee, Kyeong-Hee (Department of Dental Hygiene, Shin Heung College University)
Kim, Soo-Kyung (Department of Dental Hygiene, Shin Heung College University)
Kim, Wook-Tae (Department of Dental Technology, Shin Heung College University)
Lee, Cheong-Jae (Department of Dental Technology, Shin Heung College University)
Song, Woon-Heung (Department of Clinical Laboratory Science, Shin Heung College University)
Ma, Sang-Chull (Department of Radiologic Science, Shin Heung College University)
Publication Information
Journal of radiological science and technology / v.33, no.1, 2010 , pp. 1-10 More about this Journal
Abstract
Dental panoramic radiography is an imaging technique which shows the information of teeth, jaws and superficial structures on a single image. In this study, we propose the clinical dose reference for dental panoramic radiography. Dental panoramic radiography is an application which can increase the radiation does of oral cavity. It is very important to study the real condition of management for these panoramic X-ray equipments. Since there was no researches on dental panoramic equipments in domestic and foreign study groups, we measured and analyzed the dose such as effective dose, DAP and DWP of panoramic radiography.
Keywords
Panoramic radiography; Dose;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Dula K, Mini R, Lambrecht JT, van der Stelt PF, Schneeberger P, Clemens G, Sanderink H, Buser D : Hypothetical mortality risk associated with spiral tomography of the maxilla and mandible prior to endosseous implant treatment, Eur J Oral Sciences, 105(2), 123-129, 1997   DOI   ScienceOn
2 Manson-Hing LR, Greer DF : Radiation exposure and distribution measurements for three panoramic x-ray machines, Oral Surg Oral Med Oral Pathol, 44(2), 313-321, 1977   DOI   ScienceOn
3 Perisinakis K, Damilakis J, Neratzoulakis J, Gourtsoiannis N : Determination of dose-area product from panoramic radiography using a pencil ionization chamber : normalized data for the estimation of patient effective and organ doses, Med Phys, 31(4), 708-714, 2004   DOI   ScienceOn
4 Perisinakis K, Damilakis J, Neratzoulakis J, Gourtsoyiannis N : Determination of dose-area product from panoramic radiography using a pencil ionization chamber : normalized data for the estimation of patient effective and organ doses, Med Phys, 31(4), 708-714, 2004   DOI   ScienceOn
5 Looe HK, Eenboom F, Chofor N, Pfaffenberger A, Sering M, Ruhmann A, Poplawski A,Willborn K, Poppe B : Dose-area product measurements and determination of conversion coefficients for the estimation of effective dose in dental lateral cephalometric radiology, Radiat Prot Dosimetry, 124(2), 181-186, 2007   DOI   ScienceOn
6 Tierris CE, Yakoumakis EN, Bramis GN, Georgiou E : Dose area product reference levels in dental panoramic radiology, Radiat Protection Dosimetry, 111(3), 283-287, 2004   DOI   ScienceOn
7 Stenstroem B, Henriksson CO, Karlsson L, Sarby B : Effective dose equivalent from intraoral radiography, Swed Den J, 11(1-2), 71-77, 1987
8 Helmrot E : Systematic analysis of a radiological diagnostic system : a method for application in the effective use of X-rays in intraoral radiology, Thesis, Linkoeping University Medical Dissertations No. 498, 1996
9 Gibbs SJ, Pujol A, McDavid WD, Welander U, Tronje G : Patient risk from rotational panoramic radiography, Dentomaxillofacial Radiol., 17(1), 25-32, 1988   DOI
10 Takahashi J, Todokoro T, Nishikawa S, Shiojima M, Kikuchi A : Patient exposures from full mouth roentgenography, orthopantomography and panagraphy. Proceedings of the 3rd International Congress of Maxillofacial Radiology, Kyoto, 199-202, 1974
11 Altonen M, Heikkila M, Mattila K : A comparative study of radiation doses received during examinations with the Pantomograph, Ortho-pantomograph, Panorex, Status-X and conventional roentgen apparatus, Proc. Finn Dent. Soc., 70(1), 67-74, 1974
12 2008년 진료비통계지표, 건강보험심사평가원, 2009
13 Visser, H : Investigation into the Optimization of Periodontal Radiography (Untersuchungen zur Optimierung der parodontologischen Rontgendiagnostik), Berlin, Germany : Quintessenz Publishing, 2000
14 Williams JR, Montgomery A : Measurement of dose in panoramic dental radiology, Br J Radiol, 73, 1002-1006, 2000
15 Looe HK, Eenboom F, Chofor N, Pfaffenberger A, Steinhoff M, Ruhmann A, Poplawski A, Willborn K, Poppe B : Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product values, Radiat Prot Dosimetry, 131(3), 365-173, 2008   DOI   ScienceOn
16 Kim EK : Leakage and scattered radiation from hand-held dental x-ray unit, Korean Oral Maxillofacial Radiol, 37(2), 65-68, 2007   과학기술학회마을
17 Williams JR, Montgomery A : Measurements of dose in panoramic dental radiology, Br J Radiol, 73, 1002-1006, 2000
18 American Dental Association and U.S. Department of Health and Human Services. The selection of patients for dental radiographic examinations. Chicago : American Dental Association ; 2004.
19 Goren AD, Lundeen RC, Deahl ST 2nd, Hashimoto K, Kapa SF, Katz JO, et al : Updated quality assurance self-assessment exercise in intraoral and panoramic radiography. American Academy of Oral and Maxillofacial Radiology, Radiology Practice Committee, Oral Surg Oral Med Oral Pathol Oral Radiol Endod., 89(3), 369-374, 2000   DOI   ScienceOn
20 Isoardi P, Ropolo R : Measurement of dose-width product in panoramic dental radiology, Br J Radiol, 76, 129-131, 2003   DOI   ScienceOn
21 Oduko J : Optimisation of patient dose and image quality in dental radiology- Over 65 time to retire your OPG? IPEM Meeting, New York, March 2001
22 IAEA : International basic safety standards for protection against ionizing radiation and the safety of radiation source. IAEA safety series No.115, Vienna, 279-280, 1996
23 Bushong SC, Glaze SA, Foster JK, Copley RL, Miller JT : Panoramic dental radiography for mass screening?, Health Phys, 25(5), 489-494, 1973   DOI   ScienceOn
24 Nilsson L, Rohlin M, Thapper K : Exposure distribution, absorbed doses, and energy imparted for panoramic radiography using Orthopantomograph model OP 5, Oral Surg Oral Med Oral Pathol, 59(2), 212-219, 1985   DOI   ScienceOn
25 International Commission on Radiological Protection, 2007 Recommendations of the International Commission on Radiological Protection, ICRP Publication 103. Ann. ICRP 37(2-4), 2007
26 Poppe B, Looe HK, Pfaffenberger A, Eenboom F, Chofor N, Sering M, Ruehmann A, Poplawski A, Willborn K : Radiation exposure and dose evaluation in intraoral dental radiology, Radiat Prot Dosimetry, 123(2), 262-267, 2007   DOI
27 Doyle P, Martin CJ, Robertson J : Techniques for measurement of dose width product in panoramic dental radiography, Br J Radiol., 79, 142-147, 2006   DOI   ScienceOn
28 Napier D, Reference doses for dental radiography, Br. Dental J., 186(8), 392-396, 1999
29 Frederiksen NL, Benson BW, Sokolowski TW : Effective dose and risk assessment from computed tomography of the maxillofacial complex, Dentomaxillofacial Radiol, 24(1), 55-58, 1995   DOI
30 Choi SC : Difference in radiation absorbed dose according to the panoramic radiographic machines, Korean J Oral Maxillofacial Radiol, 30(1), 11-15, 2000
31 Choi SC, Choi HM : Absorbed dose in the full-mouth periapical radiography, panoramic radiography, and zonography, Korean J Oral Maxillofacial Radiol, 29(1), 255-260 1999
32 Kaeppler G, Buchgeister M, Reinert S : Influence of the rotation centre in panoramic radiography. Radiat Prot Dosimetry, 128(2), 239-44, 2008
33 Wall BF, Fisher ES, Paynter R, Hudson A, Bird PD : Doses to patients from pantomographic and conventional dental radiography, Br J Radiol, 52, 727-734, 1979   DOI   ScienceOn
34 Kuba RK, Beck JO Jr : Radiation dosimetry in Panorex roentgenography. Part 3. Radiation measurements, Oral Surg Oral Med Oral Pathol, 25(2), 393-404, 1968   DOI
35 Weissman DD, Longhurst GE : Comparative absorbed doses in periapical radiography. II. Panorex, Oral Surg Oral Med Oral Pathol, 33(4), 661-668, 1972   DOI   ScienceOn
36 Stenstroem B, Julin P, Karlsson L : Comparison between panoramic radiographic techniques. Part IV : absorbed doses and energy imparted from the Orthopantomograph, model OP 10, Dentomaxillofacial Radiol, 16(1), 11-15, 1987   DOI
37 Underhill TE, Chilvarquer I, Kimura K, Langlais RP, McDavid WD, Preece JW, et al : Radiobiologic risk estimation from dental radiology. Part I. Absorbed doses to critical organs, Oral Surg Oral Med Oral Pathol, 66(1), 111-120, 1988   DOI   ScienceOn
38 Bankvall G, Engstrom H, Engstrom C, Hollender L : Absorbed doses in the craniofacial region during various radiographic and radiotherapeutic procedures, Dentomaxillofacial Radiol, 14(1), 19-24, 1985   DOI
39 Bristow RG, Wood RE, Clark GM : Thyroid dose distribution in dental radiography, Oral Surg Oral Med Oral Pathol, 68(4), 482-487, 1989   DOI   ScienceOn
40 Velders XL, J van Aken, van der Stelt PF : Risk assessment from bitewing radiography. Dentomaxillofacial Radiol, 20(4), 209-213, 1991   DOI
41 White SC : Assessment of radiation risk from dental radiography, Dentomaxillofacial Radiol, 21(3), 118-126, 1992
42 Danforth RA, Clark DE : Effective dose from radiation absorbed during a panoramic examination with a new generation machine, Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 89(2), 236-243, 2000   DOI   ScienceOn
43 Lecomber AR, Faulkner K : Conference Proceeding : Dose and risk in Dental Radiography, Radiat Prot Dosimetry, 80, 249-252, 1998   DOI   ScienceOn
44 Frederiksen NL, Benson BW, Sokolowski TW : Effective dose and risk assessment from film tomography used for dental implant diagnostics, Dentomaxillofacial Radiol, 23(3), 123-127, 1994   DOI
45 Gori C, Rossi F, Stecco A, Villari N, Zatelli G : Dose evaluation and quality criteria in dental radiology, Radiat Prot Dosimetry, 90, 225-227, 2000   DOI   ScienceOn
46 Lecomber AR, Downes SL, Mokhtari M, Faulkner K : Optimisation of patient doses in programmable dental panoramic radiography, Dentomaxillofacial Radiol, 29(2), 107-112, 2000   DOI   ScienceOn
47 Gijbels F, Bou Serhal C, Willems G, Bosmans H, Sanderink G, Persoons M, Jacobs R : Diagnostic yield of conventional and digital cephalometric images : a human cadaver study, Dentomaxillofacial Radiol, 30(2), 101-105, 2001   DOI   ScienceOn
48 Maillie HD, Gilda JE : Radiation-induced cancer risk in radiographic cephalometry, Oral Surg Oral Med Oral Pathol, 75(5), 631-637, 1993   DOI   ScienceOn
49 Visser H, Rodig T, Hermann KP : Dose reduction by direct-digital cephalometric radiography, Angle Orthodontist, 71(3), 159-163, 2001
50 Scaf G, Lurie AG, Mosier KM, Kantor ML, Ramsby GR, Freedman ML : Dosimetry and cost of imaging osseointegrated implants with filmbased and computed tomography, Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 83(1), 41-48, 1997   DOI   ScienceOn
51 Avendanio B, Frederiksen NL, Benson BW, Sokolowski TW : Effective dose and risk assessment from detailed narrow beam radiography, Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82(6), 713-719, 1996   DOI   ScienceOn
52 김병삼, 최갑식, 김진수 : 파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포, 치과방사선, 20(2), 253-264, 1990
53 김애지, 나경수, 도시홍, 김현자, 유명진 : 각이등분법 및 평행법에 의한 전악 구내 표준촬영시 두경부 피부흡수선량 비교, 치과방사선, 20(2), 315-333, 1990
54 조봉혜, 나경수, 이애련 : 파노라마 촬영시의 두경부 주요기관의 등가선량, 유효선량 및 위험도, 치과방사선, 25(2), 437-445, 1995
55 Cederberg RA, Frederiksen NL, Benson BW, Sokolowski TW : Effect of the geometry of the intraoral position-indicating device on effective dose, Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 84(1), 101-109, 1997   DOI   ScienceOn
56 Dula K, Mini R, van der Stelt PF, Buser D : The radiographic assessment of implant patients : decision-making criteria, Int J Oral Maxillofacial Implants, 16(1), 80-89, 2001
57 Gijbels F, Jacobs R, Sanderink G, De Smet E, Nowak B, Van Dam J, Van Steenberghe D : A comparison of the effective dose from scanography with periapical radiography, Dentomaxillofacial Radiol, 31(3), 159-163, 2002   DOI   ScienceOn