• 제목/요약/키워드: Condition Rating

검색결과 349건 처리시간 0.027초

비대칭 전압 불평형에 의한 커패시터 동작 특성 (A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance)

  • 김종겸;박영진
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.

순수티타늄 용접재의 잔류응력분포에 관한 연구 (A Study on the Residual Stress Distribution of Pure Titanium Welding Material)

  • 최병기;장경천
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.8-13
    • /
    • 2004
  • The purpose of this paper is to investigate the welding residual stress distribution according to the constraint or non-constraint welding condition with titanium commonly using power station, aircraft, and ship. The measuring method of the residual stress was applied stress release rating method with strain gages and a potable strain meter. The x direction residual stress generally showed the tensile residual stress in case of res03int welding. On the other hand, the x direction residual stress under non-restraint welding were changed tensile stress into compressive stress on 15mm away from welding bead center. Also, the y direction residual stress generally showed the tensile residual stress in case of non-restraint welding and the y direction residual stress under restraint welding were changed tensile stress into compressive stress about 60mm away from welding bead center.

암반분류에서 RMR과 Q System의 상관성 분석 (A Study on Relationship Between RMR and Q System in Rock Mass Classification)

  • 안종필;박주원;박상도
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.737-744
    • /
    • 2000
  • This paper resorts to rock mass rating and rock mass quality to draw value based on the evaluation of rock and to draw interrelation formula in relation to rock mass quality, A comparative analysis was given of survey values reported in the existing documents. This paper has tried to find out the relationship between RMR and Q System for the sake of choosing rational reinforcing patterns and of the safety of tunnels. The results run as follow: RMR=8.251n(Q)+43.83. This paper has also tried to find out the relationship between RMR and Q System by using Fuzzy Approximate Reasoning Concept. We suggest that those in charge should not depend on a single system only after evaluating the classification of rocks, and compare one result with another for the good of keeping track of the condition of base rocks in a better way.

  • PDF

한일 주택성능등급표시제도 비교 분석 (Comparative Analysis of the Housing Performance Grading indication System in Korea & Japan)

  • 김수암;이성옥;신성은
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년 춘계학술발표대회 논문집
    • /
    • pp.226-229
    • /
    • 2009
  • Housing Performance Grade Indication System is one of the advanced system which operate globally in three countries. Housing Performance Grade Indication System of the Japan and Korea has points of similarity and distinction according to special situations of own condition and government. The purpose of a study is how characteristics have points of view about background, composition and an outline of the system, indication standard and method, the situation of issue, making progress direction and what is the clear differences. Also, it is to obtain hints for making progress direction of domestic Housing Performance Grade Indication System. The method of study is in parallel with literature survey, also collection through visiting to researcher, operation company, evaluation institution, housing company of the Japan. and to use data as a result of international workshop on November 2008. Because domestic research team is studying about making system and evaluation, revision, this study will make use this data.

  • PDF

집광추적형 PV발전의 특성에 관한 연구 (Characteristics of Photovoltaic Power Generation by Concentration and Tracking)

  • 김봉래;박상규;오현경;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.39-40
    • /
    • 2005
  • Photovoltaic Power Generation system occupies an important position as an alternative energy source, converting directly sunlight into electricity,using a photovoltaic cell. The Purpose of this research is to present and confirm the effectiveness of concentration and tracking of sun in photovoltaic power generation. Comparative experiments were carried outwith two rating 75 watt solar modules in $25^{\circ}$ under condition of various times concentration, tracking and plain normal measuring generated voltages, currents and temperatures of back sheet of modules by internet monitoring system to find out which is best in economic sense. The experiments show that output power of concentration and tracking photovoltaic power generation is over 180% more then that of plain normal system.

  • PDF

PSC 거더교의 파괴실험 (Destructive Load Testing of Prestrissed Concrete Girder Bridge)

  • 오병환;김광수;유영;유동우;김도균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.470-475
    • /
    • 2000
  • This research covers the resting of precast/prestressed concrete I-Girder bridge. The research was designed to examine processes for improving the condition evaluation and rating of prestressed concrete bridge. To establish procedures that allow for the full utilization of prestressed concrete bridge capacity, a 28-year old sample was loaded to failure in site. The bridge was constructed with 12 spans, and girders of each span were simply supported. At each loading stage, the deflections, reinforcement strains, prestressing wire strains and concrete strains were examined. Failure behavior was analyzed, and failure load was also evaluated. The test results wee compared to the analytical results from the non-linear finite element analysis.

  • PDF

154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향 (An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation)

  • 조성수;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

아크 용접에 적합한 영전압영전류 방식의 풀브릿지 컨버터 (A Zero-Voltage and Zero-Current Switching Full Bridge DC-DC Converter for Arc Welding Machines)

  • 전성즙
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권6호
    • /
    • pp.342-348
    • /
    • 1999
  • A new welding machine which adopts zero voltage and zero current switching(ZVZCS) full bridge(FB) DC-DC converter is proposed. The proposed ZVZCS FB DC-DC converter uses auxiliary transformer to obtain ZCS for leading leg. It has capability of controlling load current even in short circuit condition and is suitable for arc welding machines. The power rating of the auxiliary transformer is about one 5th to one 10th of the main transformer. Experimental results for 10KW prototype are shown to verify the principle of operation.

  • PDF

180kW급 돌극형 동기발전기의 기념설계 및 정상상태 전자계 해석 (Conceptual Design and Steady State Electro-Magnetic Analysis of 180kw Alternator with Salient Pole)

  • 하경덕;박도영;황돈하;김용주;조삼출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.24-26
    • /
    • 1999
  • In this paper, the conceptual design and FE analysis results of salient pole type alternator under no load condition are described. The designed alternator's rating is 180kW, 3-phase, 4pole, 380/220V, 0.8pf, 60Hz. The conceptual design is described by the process of designing the armature, field, and obtaining some of equivalent circuit parameters. The comparison of FE analysis to the designed results of alternator's output voltage value shows a good agreement.

  • PDF

불소수지를 이용한 분할형 PET/nylon 직물의 발수가공 (Water Repellent Finish for Divided Type PET/Nylon Fabrics with Fluoro Alkyl Resin)

  • Lee, Bang One;Pak, Pyong Ki;Cheong, Yun Suk;Lee, Hwa Sun
    • 한국염색가공학회지
    • /
    • 제9권4호
    • /
    • pp.1-6
    • /
    • 1997
  • Water repellent finish was carried out using water repellent agent(AG-480), melamine resin(Sumitex Resin MK), and catalyst(Sumitex Accelerator ACX). PET/nylon fabrics were treated with melamine resin by pad-dry-cure method and subsequently washed and dried. Durable water repellency was controlled by the melamine resin and catalyst. Water repellency was tested by spray rating method and durability of water repellency were measured by launder-O-meter and pilling tester. The optimum conditions of durable water repellent finish for new synthetic fabric were as follows; concentration of water repellent finishing agent 20g/l; concentration of melamine & catalyst 0.5g/l; curing condition $160^{\circ}$ ${\times}$ 30sec. Water repellency after washing and rubbing is improved by melamine resin and catalyst.

  • PDF