• 제목/요약/키워드: Condition Changes Prediction

검색결과 120건 처리시간 0.026초

일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석 (A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital)

  • 양남희;정운관;동경래;최은진;주용진;송하진
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

경계 조건과 불포화 함수 특성 곡선의 이력에 따른 불포화 토사 사면의 수리적 거동 분석 (Analysis of Hydraulic behavior in Unsaturated Soil Slope for the Boundary Condition and Hysteresis of SWCC)

  • 이어령;박현수;박성완
    • 한국지반공학회논문집
    • /
    • 제39권1호
    • /
    • pp.15-25
    • /
    • 2023
  • 최근 집중 강우의 증가로 인한 사면 붕괴가 증가하고 있으며, 대규모 사면 붕괴가 빈번하게 발생하고 있다. 사면 붕괴로 인한 인명 및 재산 피해를 최소화하기 위해서 사면 경보 시스템에 사면 계측이 활용되고 있다. 사면 계측은 특정 지점에서 대한 결과를 측정하기 때문에 전반적인 사면의 거동을 파악하기 어려우므로 수치 해석을 함께 수행되어야 한다. 강우 침투시 사면의 거동을 파악하기 위해서 강우 뿐만 아니라 증발산이 고려되고 있으며, 불포화 함수 특성 곡선의 건조 과정을 적용하여 수치해석이 진행 되고 있다. 하지만, 불포화 함수 특성 곡선의 이력 현상은 수치해석 결과에 영향을 미친다. 따라서, 본 연구에서는 증발산 산정 방법과 증발산을 경계 조건에 적용하는 방법을 제시하고, 불포화 사면의 현장 계측 결과와 경계 조건과 침투 조건을 고려한 수치해석 결과를 비교하였다. 계측 지점의 흡수력 변화와 상관 계수를 비교하였을 때, 불포화 함수 특성 곡선의 건조과정과 습윤과정에 따라 증발산에 대한 영향이 다르게 나타났다. 또한, 증발산 적용을 통하여 건기와 우기시의 흡수력 변화가 실제 계측 결과와 근접하게 나타나는 것을 통하여 증발산 적용시 불포화 사면의 지표면에서 발생하는 수분 이동을 더 합리적으로 예측할 수 있다고 판단된다.

RCP 시나리오에 따른 미래 전지구 육상탄소순환 변화 전망 (Future Changes in Global Terrestrial Carbon Cycle under RCP Scenarios)

  • 이철;부경온;홍진규;성현민;허태경;설경희;이조한;조천호
    • 대기
    • /
    • 제24권3호
    • /
    • pp.303-315
    • /
    • 2014
  • HadGEM2-CC 모델에서의 $CO_2$ 농도증가에 대한 RCP 시나리오의 결과는 21세기 말 전 지구 연평균 기온과 강수 증가가 전망되고 이에 따라 식물의 생산량 및 호흡량 증가가 전망된다. 20세기 말 일차생산량(GPP와 NPP), 호흡량, LAI가 21세기 말 기온 증가에 따라 증가하는 점은 기존의 Shao et al. (2013)와 유사하였다. 특히 이전 연구와 유사하게 21세기 말 일차생산량과 호흡량은 고위도보다 열대 저위도 지역에서 증가량이 더 컸다. 기온이 상승하고 강수량이 증가하면서 식생이 자라지 않던 나지 면적이 감소하였고, 이에 따른 식생 면적 증가는 식생의 생산량(GPP, NPP) 증가로 나타났다. 특히, 본 연구에서는 C3 초지, 활엽수의 면적 증가가 뚜렷하였다. 이는 Beck and Goetz (2011)에서 언급한 대로 온난화에 따른 식생 면적 증가가 식생 생산성과 연관되어 $CO_2$ 흡수작용을 강화하는 데 기여할 수 있음을 의미한다. Shao et al. (2013)에 따르면 21세기 말 누적 NEE는 증가가 전망되고 이는 특히 열대와 고위도 지역이 주요 흡수원으로 작용하였기 때문으로 그 원인을 설명하였다. 본 연구에서 사용된 HadGEM2-CC에서는 전 지구 평균적으로 NEE 흡수가 증가하는 경향은 동일하게 전망하며, 이는 열대보다는 북반구 고위도지역인 유라시아와 북미 대륙에서 증가한 흡수가 그 원인으로 분석되었다(Fig. 8). 앞서 Mynenl et al. (1997)에 따르면 기온상승에 따라 식생의 광합성활동, 생장시기 길이와 시작시기의 당겨짐을 보고하였다. 본 연구 실험에서도 이와 유사하게 미래에 기온 상승에 따라 식생 성장 기간이 길어지고 LAI도 증가하며 식생 지대가 점차 고위도로 북상할 것을 전망하였다(Figs. 5, 12b). 이에 따라 육상 생태계의 $CO_2$ 흡수량은 20세기 말보다 21세기 말에 증가하였고 우리나라가 속해있는 동아시아지역($90^{\circ}E{\sim}140^{\circ}E$, $20^{\circ}N{\sim}60^{\circ}N$)은 기온, 강수뿐 아니라 $CO_2$ 흡수량도 같은 위도대의 전 지구 동서평균보다 크게 모의되었다. RCPs에 따른 흡수율은 21세기 중반까지는 대기 중 이산화탄소 농도 변화율과 유사한 경향을 보이는데 RCP 8.5에서는 21세기 후반에 흡수 증가율이 감소하며 이는 Liddicoat et al. (2013) 에서 보인것과 유사하다. 하지만 대기 중 $CO_2$의 증가와 식생분포 지역의 확대에도 불구하고 21세기 말 육상생태계의 순생태계흡수량은 크게 증가하지 않음을 확인할 수 있었다. 이는 기온 상승이 크게 일어난 21세기 후반부터 토양 호흡의 급격한 증가로 인하여 육상생태계의 이산화탄소 흡수 능력은 감소한 것에 기인하였다. 향후 본 연구결과의 유의성을 확보하기 위해 다양한 모델의 자료를 추가할 필요가 있다. Shao et al. (2013)에 따르면 미래 탄소 흡수 전망에 있어 전 지구 및 위도별 모의 결과가 모델마다 매우 다양한데 이는 지면생태모형 간의 식생역학, 물리과정의 차이로 해석된다. 미래 육상생태계의 이산화탄소 흡수 능력의 변화와 기후변화를 보다 정확하게 예측하기 위해서는 다른 모델의 자료를 이용한 불확실성을 정량화 하는 것이 필요하며 이는 전 지구 및 지역별 탄소 순환 이해를 높이는 데 기여할 것이다.

RCP 시나리오 및 전지구 수문 모형을 활용한 아시아 미래 수문인자 예측 (Prediction of future hydrologic variables of Asia using RCP scenario and global hydrology model)

  • 김다운;김다은;강석구;최민하
    • 한국수자원학회논문집
    • /
    • 제49권6호
    • /
    • pp.551-563
    • /
    • 2016
  • 기후변화에 관한 정부간 협의체 (Intergovernmental Panel on Climate Change; IPCC)의 4차 및 5차 보고서에 따르면 인류 활동에 의한 기후변화가 산업혁명 이후 급속하게 진행되고 있다고 한다. 기후변화는 주로 온도와 이산화탄소 농도의 변화로 감지되는데, 지난 100여년 간 지구 평균 온도는 $0.74^{\circ}C$ 상승하였으며, 대기 중 이산화탄소의 농도는 최소 800,000년 동안의 최대치를 기록하였다 (IPCC, 2007, 2014). 이러한 기후 변화는 수문학 연구에서 중요한 강수, 증발산, 토양수분 등에도 커다란 영향을 미치므로 이에 대한 꾸준한 연구가 필요하다. 따라서 본 연구에서는 아시아 지역을 대상으로 1951년부터 2100년까지의 주요 에너지 인자들에 대한 모의를 실시하였다. 전 세계적으로 다양한 분야에서 사용되고 있는 Common Land Model을 미래 예측을 위한 기반으로 활용하였으며, 강제입력자료는 기후변화에 대응하기 위하여 IPCC 5차 보고서에 소개된 가장 최신의 온실가스 시나리오인 대표농도경로 (Representative Concentration Pathway; RCP)를 활용하였다. 과거 기간에 대한 순복사량, 현열 및 잠열에 대한 검증은 Asiaflux 사이트에 속한 5개 지점의 자료를 활용하여 수행하였으며, 모든 인자들에 대하여 모형의 월별 경향성이 관측 자료와 거의 일치함을 확인하였다. 미래 기간의 모의에 대해서는 RCP 4.5 및 RCP 8.5를 활용한 모의 모두 순복사량은 거의 변화가 없었으며 현열은 대체적으로 하강하는 경향을, 이와 대조적으로 잠열의 경우에는 상승하는 경향을 나타내었다. 특히 RCP 8.5를 활용한 결과에서 이 증감폭은 더 크게 나타났으며, 2060년대 후반부터 순복사량과 현열의 변동성이 매우 커지는 등의 극한기후의 특징을 나타내는 것으로 보인다. 추후 연구에서는 본 연구를 토대로 다양한 시나리오를 활용하여 더욱 다양한 조건하에서의 에너지 인자 및 다른 수문학적 주요 인자들에 대한 모의를 수행할 예정이다.

홍수 규모별 대청호에 유입하는 하천 밀도류의 특성 변화 (Variation of Inflow Density Currents with Different Flood Magnitude in Daecheong Reservoir)

  • 윤성완;정세웅;최정규
    • 한국수자원학회논문집
    • /
    • 제41권12호
    • /
    • pp.1219-1230
    • /
    • 2008
  • 여름철 홍수시 성층화된 저수지로 유입하는 하천수는 저수지 표층수에 비해 낮은 수온과 높은 부유고형물질(SS) 농도를 가지므로 주변수에 비해 상대적으로 높은 밀도를 가지게 된다. 이러한 밀도차로 인해 형성된 밀도류의 저수지 내 진행과정은 수질과 수생태계에 큰 영향을 주게 된다. 따라서 하천수 밀도류의 거동분석은 저수지 수질관리를 위한 현장조사의 최적화, SS와 영양염류 등 오염물질의 이송 확산 해석에 중요한 요소이다. 본 연구의 목적은 기존 연구를 통해 검증된 2차원 수치모델을 이용하여 다양한 홍수규모에서 대청호로 유입하는 하천 밀도류의 거동 특성인 침강점 수심($d_p$)과 거리($X_p$), 분리점 수심($d_s$), 중층류 관입두께($h_i$), 댐축 도달시간($t_a$), 감소율(${\beta}$)을 분석함으로써 저수지 수질관리를 위한 기초정보를 제공하는데 있다. 모의조건은 평수년이었던 2004년 6월 13일부터 7월 3일 동안 발생한 홍수사상의 수문곡선을 기준으로 유입 유량의 규모를 10개의 등급으로 나누었으며, 초기 성층조건은 탁수가 유입되기 전의 발달된 성층구조를 적용하였다. 유입수와 저수지 성층구조의 특성치는 밀도 Froude 수(Fri)로 나타내었으며, 10개의 $Fr_i$ 조건별로 $d_p,\;X_p,\;d_s,\;h_i,\;t_a$, SS의 ${\beta}$값 등을 산정하였다. 연구결과 $d_p,\;X_p,\;d_s,\;h_i$는 대체로 $Fr_i$ 값과 비례하여 증가하였으며 중층류의 진행속도도 빨라지는 경향을 나타내었으나, 저수지 지형변화에 큰 영향을 받는 것으로 나타났다. 정상상태를 가정하는 Hebbert 식은 저수지 수위변화와 지형변화를 고려하지 못하기 때문에 수치모델 보다 $d_p$값을 과대 산정하였다. 유입 SS 농도의 감소율(${\beta}$)은 $Fr_i$가 클수록 작아지는 경향을 보였으나, $Fr_i$>9.0에서는 난류혼합효과 때문에 다시 증가하였다. 연구결과는 저수지운영 실무자들이 홍수규모별로 탁수의 초기 거동특성을 간단히 예측하는 목적으로 사용할 수 있다.

본태성 고혈압 환자의 자가간호증진을 위한 자기조절 프로그램 효과 -Orem이론과 Bandura이론의 합성과 검증- (An Effect of the Self-Regulation Program for Hypertensives -Synthesis & testing of Orem and Bandura's theory-)

  • 박영임;홍여신
    • 지역사회간호학회지
    • /
    • 제5권2호
    • /
    • pp.109-129
    • /
    • 1994
  • Chronic health problems has become a major concern and challenge to the health care professionals today. Especially hypertension, one of the leading primary cause of death in Korea, is a typical chronic disease requiring adequate and continuous management. Though these hypertensives need to maintain desirable health practice by themselves for their life time, many previous studies indicated that most of the essential hypertensives have no specific symptoms and thus, reluctant to follow appropriate medical regimens causing the condition further aggravated and complicated. Self-care is an essential factor that keeps chronic patients in control of their health and wellness. Thus this study was conducted to identify the effect of the comprehensive self-regulation program as a nursing intervention on the promotion self-care performance and improvement in physical parameters of hypertensives. For this purpose, a one group quasi-experimental research with pre and post test design was used. The subjects of the study was consisted of thirty persons with mild or moderate essential hypertension from two companies in Cheong-ju city. The whole program was carried out from October, 1993 to February, 1994. The self-regulation program was consisted with group education on hypertension and self-care, self-regulation including the blood pressure self-monitoring and recording, recording of daily self-care activities, and encouraging and reinforcing self-efficacy through verbal persuation and enactive attainment. The subjects were asked to measure their own blood pressure by themselves twice per day and to record blood pressure and the daily self-care performance according to the instructions provided during the whole period of 9 weeks. The instruments used for data collection in this study were as follows : 1) Instruments used for measuring the knowledge about hypertension, multiple health locus of control, and perceived benifits and barriers were adapted from previous studies and modified by author to be fit for the subjects. 2) Self-efficacy scale and self-care performance record were developed by the author. 3) Physiological parameters included systolic / diastolic blood pressure, body weight, level of blood cholesterol, and 24hour ambulatory blood pressure. The post-experimental Cronbach's Alpha as the reliability test of scales were 0.703-0.897, an appropriate level of confidence. The effect of the program was analyzed by experimental stages ; the first week, the fifth week, and the ninth week since the experimental imput began. Data were analyzed by the SPSS PC+ program with paired t-test and t-test, repeated measure ANOVA, and pearson's correlation to de termine the effect of program. The results were as follows : 1) After the self-regulation program, scores on knowledge(t=-2.41, p=.011), perceived self-efficacy (F=5.60, p=.001), self-care performance(F=22.31, p=.0001) were significantly higher than those before the program. 2) After the program, both systolic and diastolic blood pressure were significantly lower than those before the program(F=10.89 -13.11, p=.0001). However in 24hour ambulatory blood pressure, systolic mean pressure was nearly significantly lower, but not in diastolic mean pressure. 3) After the program, the body weight was significant decresed(t=5.53, p=.0001), but the blood cholesterol level was not decreased significantly except in those cases with higher cholesterol level. 4) There were significant relationships between changes in self-care performance and diastolic pressure at 1st week (r=.3389, p=.033) and changes in self-care performance and systolic pressure at 9th week(r=.3651, p=.024). 5) There were significant relationship between perceived self-efficacy and self-care performance at 5th week(r=.5313, p=.001) and 9th week (r=.3026, p=.052). 6) After the program, internal health locus of control and perceived benefits did not show significant change, but perceived barriers was significantly lower than those before the program (t=3.57, p=.0001). From the above results, it can be concluded that 1) The self-regulation program is an effective nursing strategy to promote self-care performance of hypertensives and to lower the blood pressure. Thus this program can be recommended in the management of the hypertensives in workplaces and community settings. 2) The synthesis of Orem's self-care theory and Bandura's self-regulation & self-efficacy theory in this study was proved to enhance explanation and prediction of the change of self-care behavior. Thus the result of the study would contribute in development of the self-care theory and an expansion of practice-theory.

  • PDF

합천댐 하류 하천지형 변화 예측 및 흐름파가 수리기하 변화에 미치는 영향 (Channel Changes and Effect of Flow Pulses on Hydraulic Geometry Downstream of the Hapcheon Dam)

  • 신영호
    • 한국수자원학회논문집
    • /
    • 제42권7호
    • /
    • pp.579-589
    • /
    • 2009
  • 황강은 1989년 합천 본댐 및 조정지댐의 건설후 하도폭, 하상재료, 식생 및 하천구간내 사주의 형성 등 많은 하천 지형학적 변화가 있었다. 이러한 변화는 댐 건설후 흐름 및 유사이송의 변화에 기인한다. 합천댐은 약 591천 $m^3$/년의 유사를 차단한 것으로 파악되었다. 조정지댐 준공후 연최대피크 방류량은 654.7 $m^3$/s에서 126.3 $m^3$/s로 감소되었다 (댐건설전의 19.3%). 합천조정지댐 하류로부터 낙동강 합류점까지 45 km 구간의 1982, 1993 및 2004년의 항공사진을 분석한 결과 비식생하도폭(non-vegetated active channel width)은 평균 152m 감소되었다 (1982년의 약 47%). 비식생하도의 면적 역시 평균 6.6$km^2$ (1982년의 44%)가 감소하였다. 평균 중앙입경(D50)의 크기는 1983년 및 2003년에 1.07mm에서 5.72 mm로 평균 하상구배는 0.000943에서 0.000847로 각각 변하였다. 하상 세굴깊이는 조정지댐으로 부터 하류 20 km 구간에서 평균 약 2.6 m였다. 1차원 유사모형인 GSTAR-1D를 이용하여 장기하상변동을 예측하였는데 최심하상고는 2013-2015년 사이에 안정된 상태에 도달하는 것으로 나타났다. 합천 조정지댐에 의해 홍수기에 발생되는 흐름파가 하류 하천 지형변화에 미치는 영향을 파악하기 위해 해석적인 방법을 개발하고 유사모의모형으로 예측한 값과 비교 검토한 결과, 일주기파(daily pulse)와 홍수피크(flood peak)는 각각의 평균값이 흐를 때와 비교하여 하천지형변화에 훨씬 큰 영향을 미치는 것으로 나타났는데 이는 각각의 평균일 경우 보다 21%와 15%의 유사이송량의 증가를 보여주었다.

신 기후변화시나리오에 따른 한반도 내 겨울보리 재배적지 이동 (Geographical Migration of Winter Barley in the Korean Peninsula under the RCP8.5 Projected Climate Condition)

  • 김대준;김진희;노재환;윤진일
    • 한국농림기상학회지
    • /
    • 제14권4호
    • /
    • pp.161-169
    • /
    • 2012
  • 변화된 미래 기후조건에서 한반도의 식량수급전망에 긍정적 변수로 떠오르고 있는 가을보리의 안전재배지대 재설정 및 잠재 생산량 추정을 위해 한반도 지역 RCP8.5 기반 미래 기온전망을 현재 평년의 상세 전자 기후도와 결합하여 2011-2100 기간 중 보리 품종군별 재배안전지대의 지리적 변화를 10년 단위로 예측하였다. 먼저 1971-2000 기간 중 1월 최저기온과 평균기온 분포도를 30m 격자 해상도로 남북한 전역에 걸쳐 준비하고, 이 기준 기온분포도 위에 기상청의 RCP8.5 기반 한반도 12.5km 시나리오 기후자료에서 산출한 기준평년 기점의 10년 단위 기온상승폭을 중첩시켰다. 2100년까지 매 10년 단위 1월의 최저기온과 평균기온의 예상분포도상에 농촌진흥청에서 제시한 보리 추파재배 시 품종군별 안전월동기준에 따라 재배안전지대를 표현한 결과, 2020년대에는 강원도와 북한 남부 대부분 지역에서 겉보리 재배가 가능해지며 남한 전역에서는 쌀보리 재배가 가능해질 것이고, 2040년대에는 북한 평야지대 거의 모든 벼논에서 쌀보리 이모작이 가능해질 것으로 예상되었다. 현재 파악되고 있는 북한의 경지면적은 160만 ha 인데, 2040년대 이후 북한지방의 논에는 벼 수확 후 쌀보리를, 밭에는 옥수수, 감자 후작으로 겉보리를 재배한다면 연간 최대 400만 톤의 식량을 추가로 확보할 수 있을 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF