• Title/Summary/Keyword: Condensing Boiler

Search Result 48, Processing Time 0.025 seconds

A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers (가스보일러 일산화탄소 누출사고 경감에 관한 연구)

  • Song, Jaechang;Kwon, Hweeung;Lee, Younghee;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.277-281
    • /
    • 2012
  • This work is concerned with a plan for preventing accidents of CO gas leak from gas boilers, involving the enforcement of installations of both CO alarm system and condensing boilers, and financial support of government grants. If amongst 1,460,000 beneficiaries of basic livelihood security, one million households in use of gas boilers receive 3-year support of 200,000 won, the difference of prices between common and condensing boilers, the government grants would be 2,000 billion won. If 3 million common householders are in 3-year support of 100,000 won, government grants would be 3,000 billion won. Therefore, 3-year grand total of government grants would be 5,000 billion won. Finance for government grants can be purveyed from energy saving; yearly 2,000 billion won of energy saving by enforcing to replace one million existing boilers with condensing boilers, leading to 2 trillion won of energy saving for 10 years. In this way, 6,000 billion won of 3-year grand total of government grants for CO alarm system and condensing boilers can be purveyed. The rest amount would be fundraised for energy savings. We claim that our proposal can make an achievement of more than 50% reduction of CO leak accidents during 10 years.

Design of Rankine Steam Cycle and Performance Evaluation of HT Boiler for Engine Waste Heat Recovery (엔진 폐열 회수를 위한 랭킨 스팀 사이클 설계 및 HT Boiler의 성능 평가)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Lee, Dong-Hyuk;Lee, Heon-Kyun;Kim, Tae-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.21-29
    • /
    • 2012
  • A dual loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop (HT loop) only recovers the heat of the exhaust gas. A low temperature loop (LT loop) recovers the residual heat from the HT loop, the coolant heat and the remaining exhaust gas heat. The two separate loops are coupled with a heat exchanger. This paper has dealt with a layout of the dual loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the HT boiler, a core part of a HT loop, have been presented. The prototype of the HT boiler was evaluated by experiment. For the performance evaluation of the HT boiler, inlet temperature of the HT boiler working fluid was set equal to the temperature degree of sub-cool of $5^{\circ}C$ at the condensing pressure. The exit condition was the degree of super-heat set at $5^{\circ}C$. The characteristics of the HT boiler such as heat recovery and pressure drops of fluids were evaluated with varying flow rates and inlet temperatures of exhaust gas under various evaporating pressure conditions.

Experimental Study of Condensation Heat Transfer in Pre-heating Exchanger to the Type of Hydrophilic Surface Treatment (친수 표면처리 종류에 따른 공기 예열 열교환기의 응축 열전달 실험적 연구)

  • Seok, Sungchul;Chung, Tae-Yong;Chin, Donghoon;Hwang, Seungsik;Choi, Gyuhong;Park, Jaewon
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.237-238
    • /
    • 2012
  • Recently, an energy-saving due to the energy utilisation efficiency enhancement is important. In order to improve the heat efficiency of the general residential boiler, We performed an experiment of condensation heat transfer to air pre-heat exchanger adhered to the condensing boiler. In this research, We analyze the heat transfer performance through the hydrophilic surface treatment(plasma, etching). The results of the research, On plasma and etching treated surface, Overall heat transfer coefficient is displayed the tendency to increase.

  • PDF

Combustion characteristics and gas interchangeability of natural gas with various compositions (다양한 성분을 가지는 천연가스의 연소특성 및 호환성)

  • kim, Jong-min;Yu, Byeonghun;Lee, Seungro;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.89-91
    • /
    • 2012
  • In this study, an investigation into the gas interchangeability and combustion characteristics of natural gas with various compositions was performed. In order to suggest the appropriateness of gas interchangeability using the specific gravity(SG) and the Wobbe index(WI) values, combustion characteristics, which include incomplete combustion and flame lifting, were measured and observed for the upper and lower limits using the gas-oven as a domestic partial-premixed type appliance and the condensing boiler as a domestic premixed type appliance.

  • PDF

Combustion and Emission Characteristics of the Surface Flames in Porous Ceramic Burner (다공세라믹 버너를 이용한 표면화염의 연소 및 배기특성)

  • Hwang, Sang-Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.1
    • /
    • pp.29-35
    • /
    • 2001
  • The surface flames in porous ceramic burner are experimentally characterized to investigate the effects of equivalence ratio and firing rates. The results show that the surface flames are classified into green, red radiant and blue surface flame as decrease of equivalence ratio. And each flame is maintained very stably and shows the same flame characteristics at any orientation of ceramic burner. Particularly the blue surface flame was found to be very stable at very lean equivalence ratio at 200 to $800\;kw/m^2$ firing rates. And the exhausted NOx was analysed to find out which flame has lower NOx emission. The blue surface flame showed the lowest NOx emission regardless of the location of burner since it sustained very stable at lean mixture ratio.

  • PDF

A Study on the Effects of Etching Surface Characteristics on Condensation Heat Transfer in Pre-heating Exchanger (급기 예열 열교환기에서 에칭 표면 특성이 응축 열전달에 미치는 영향에 관한 연구)

  • Seok, Sungchul;Hwang, Seung Sik;Choi, Gyu Hong;Shin, Donghoon;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.217-222
    • /
    • 2014
  • In order to improve the heat efficiency of the general residential boiler, we performed an experiment of condensation heat transfer to air pre-heating exchanger adhered to the condensing boiler. In this study, surface roughness was imposed on the surface of stainless steel by etching. And in order to evaluate the heat transfer performance on each plate, the counter flow heat exchanger fabricated with polycarbonate in used. As a result, on etching treated plate's overall heat transfer coefficient is higher than the original plate. And etching treated plate during 60 seconds with etchant is the to average 15% compared to bare stainless steel. And we studied the heat transfer enhancement factor through the analysis of surface characteristics using AFM.

The Effect of Load Variation on the Performance of an Injection Heat Pump with an Economizer (이코너마이저 적용 열펌프 시스템의 부하변화에 따른 성능 특성 연구)

  • Choi, Jong Min;Park, Yong-Jung;Kang, Shin-Hyung
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • Heat pumps have received a fair amount of attention all over the world for their high efficiency and low environmental impact. Employing heat pumps for residential heating and cooling produces only about 2038 kg-$CO_2$/year, an amount which is less than half that of conventional boiler systems. However, the use of single-stage heat pumps becomes uneconomical when they are operated at very low evaporating temperature or high condensing temperature. Two-stage heat pumps systems can be used successfully for low or high temperature applications. In this paper, the experimental study on the performance of two-stage heat pump with an economizer was executed in heating mode. When the secondary fluid inlet temperature to the indoor heat exchanger increased, the COP enhancement rate of two-stage heat pump with an economizer was increased. For all outdoor inlet temperature conditions, the performance of the heat pump with an economizer was higher than it without an economizer.

A Study on the Condensation Heat Transfer of Low Integral Fin Tubes (낮은 핀 관의 응축 열전달 성능에 관한 연구)

  • Han, Gyu-Il;Park, Seong-Guk
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.67-77
    • /
    • 1996
  • The heat transfer performance of R - 11 vapor condensing on integral fin tubes has been studied using fin tubes having the fin density from 748 to 1654 fins per meter. Electric heater supplied heat energy to the boiler to generate R - 11 vapor over the range of 25-60W. Condensation rates of each tubes were tested under the condition of cooling water flow rate from 400l/h to 2500l/h. For the seven fin tubes tested, the best performance has been obtained with a tube having a fin density of 1417fpm and a fin height of 1.3mm. This tube has yielded a maximum value of the heat transfer coefficient of 16500W/$m_2$K, at a vapor to wall temperature difference of 3K. Experimental results of integral fin tubes have been compared with available predictive models such as Beatty - Katz's analysis, Webb's analysis, Sukhatme's analysis and Rudy's empirical relation. The experimental results were shown to be in good agreement with that of the Sukhatme's analysis.

  • PDF

The Operation Characteristics of Domestic 1kW Gas Fueled Internal Combustion Engine Cogeneration System (1kW급 가스엔진 열병합발전시스템 성능특성에 관한 연구)

  • Choi, Jae-Joon;Park, Byung-Sik;Jung, Dae-Heon;Im, Yong-Hoon;Choi, Young-Ho;Song, Dae-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.321-324
    • /
    • 2009
  • The unpredicted worldwide oil price makes the energy efficiency technology be more importance than any other period. The small cogeneration system is one of the most representative technology among the energy efficiency technologies, and recently, the household cogeneration system has been the center object of attention because of the loss of power transmission and the reasonable energy consumption relative to the household (condensing) boiler producing heat only. A tiny, 1kW of electrical output, gas fueled internal combustion engine cogeneration system was investigated. The electrical efficiency and thermal efficiency of the system were measured. With the emission characteristics, the cogeneration system was analyzed. It was showed the gas engine cogeneration system produced the lowest NOx level compared any other cogeneration system due to the three-way catalyst.

  • PDF