• 제목/요약/키워드: Condensed water

검색결과 168건 처리시간 0.036초

경사진 육면체에서의 태양열에 의한 증발효과에 대한 연구 (A Study on the Solar Distillation in a Cube with Tilted Angles)

  • 박영훈;김병철
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.13-19
    • /
    • 2004
  • Four solar stills that were fabricated each with cubes and glazing tilted angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$, were compared with the quantities of condensed water. The quantifies of condensed water were analysed with the weather conditions and temperatures for three months. On fine days, the quantify of average condensed water was more similar to those of $15^{\circ}$ and $30^{\circ}$ than to those of $45^{\circ}$ and $60^{\circ}$. The quantity of condensed water produced by those of $45^{\circ}$ and $60^{\circ}$ were very irregular compared to those of $15^{\circ}$ and $30^{\circ}$. On rainy days, the quantify of condensed water was the most in that of $30^{\circ}$ than those of the other angles and in cloudy, rainy and sunny conditions, the condensation quantify was the largest in that of $60^{\circ}$.

응축수 순환이 폐열회수 응축형 보일러 성능에 미치는 영향 (Effect of Waste Heat Recovery Condensing Boiler with Condensed Water Recirculation Function)

  • 금국빈;김수익;유병훈;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.201-204
    • /
    • 2015
  • Recently, energy excessive consumption and environmental pollution are the social issued. The most efficient way to solve both energy excessive consumption and environmental pollution is existing combustion system improved. This study was part of the assume and commercial used existing waste heat recovery condensing boiler to low emission performance for exhaust gas recirculation(EGR) and thermal efficiency rise by applying the condensed water recirculation(CWR) conducted. The researchers applied the EGR and CWR develop a new concept for the condensed water recirculation waste heat recovery condensing boiler. Waste heat recovery condensing boiler applied to the condensed water recirculation thermal efficiency of the same conditions was increased by about 4.8~5.5% and pollution emission also decreased.

  • PDF

T-분지관이 부착된 벤튜리관의 유동특성과 응축수 유입에 대한 수치해석 연구 (A numerical study on the flow characteristics and condensed water inflow in the Venturi tube with T-branch tube)

  • 김승일;박상희;황정규
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.173-181
    • /
    • 2019
  • This study was carried out numerically to investigate the flow characteristics in the Venturi tube with $90^{\circ}$ T-branch tube and the inflow of condensed water into the Venturi tube from the branch tube. In this study, the diameter of the branch tube(1, 2, 3mm) and the neck diameter of the Venturi tube(0.3, 0.9, 1.5mm) were varied. The flow rate of the water at the Venturi tube inlet is 80cc/min and the water temperature is 288K. The condensed water temperature at the branch tube inlet is 355K. It was found that the velocity and pressure of the fluid near the branch point in the Venturi tube were more dependent on the diameter of the Venturi tube than the diameter of the branch tube. The temperature of the mixed water at the exit of the Venturi tube was the highest when the Venturi tube's neck diameter is 0.9mm and the branch tube diameter is 2mm. This means that the condensed water is flowing well through the branch tube.

경사진 육면체에서의 태양열에 의한 증발 현상에 대한 연구 (A Study on the Solar Distillation in a Cube with Tilted Angles)

  • 박영훈;김병철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1424-1429
    • /
    • 2004
  • Distillation is one of many processes that can be used for the purification of water. It requires an energy input such as heat and solar radiation is a possible source of energy. In this process, water is evaporated, thus separating water vapor from the solute. The vapor is then condensed to pure water. The temperature of the water, the cavity of the enclosure and the surface of the glass was measured everyday. Fifteen points were chosen for the temperature measure using a thermocouple. The inner wall and the bottom of each still was painted black for good absorption of heat. The enforced glass was used for the cover for the entering of solar energy. The size of all of the water baths was the same, but the glass of the rectangular form had a tilted angle. In the case of fine or general weather, the volume of condensed water produced by $45^{\circ}$ and $60^{\circ}$ is very irregular compared to that of $15^{\circ}$ and $30^{\circ}$, In case of a rainy day, the occurrence of the volume of condensed water was similar to that of $15^{\circ}$ and $30^{\circ}$, but the volume of condensed water produced by $30^{\circ}$ was the highest.

  • PDF

응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구 (The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water)

  • 윤병두;임우조;정기철
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.21-25
    • /
    • 2005
  • 가스보일러용 오스테나이트계 스테인리스강재(STS 304)의 부식거동에 관해 연구하기 위하여, 응축수중에서 전기화학적 부식시험을 수행하여. STS 304의 전기화학적 부식거동을 고찰하였다. 다음과 같은 결론을 얻었다. 1)중성환경인 pH=6.5에서 pH가 낮아질수록 STS 304의 분극저항은 감소하고, 부식전위는 비전위화된다. 2)중성 및 산성환경 중에서 STS 304의 부식반응기구는 음극지배로 판단된다. 3) pH가 중성 환경인 pH=6.5에서 강산성 환경인 pH=0.5로 낮아질수록 STS 304의 부동태 전위영역이 감소하고 부동태유지 전류밀도는 증가하고 있다.

  • PDF

응축수를 활용한 열전 냉각장치의 회로 모델링 및 시뮬레이션 (Circuit Modeling and Simulation for Thermoelectric Cooling System using Condensed Water)

  • 이상윤;장석윤;박민용;윤창용
    • 한국지능시스템학회논문지
    • /
    • 제25권2호
    • /
    • pp.161-167
    • /
    • 2015
  • 본 논문에서는 응축수를 활용하는 새로운 열전 냉각장치를 소개하고 이 냉각장치에 대한 전기적 등가회로 모델을 제안한다. 소개된 냉각장치는 수집된 응축수를 히트싱크로 분무함으로써 응축수를 처리함과 동시에 냉각 효율을 향상시킬 수 있다. 기존의 열전 냉각장치에 대한 회로 모델과 열전소자-응축수 간의 열교환 방정식을 결합함으로써 소개된 냉각장치의 전기적 등가회로 모델을 유도한다. 유도된 모델의 파라미터는 별도의 실험을 통한 데이터 측정 없이 열전소자의 데이터시트 정보만으로 결정되기 때문에 소개된 냉각장치의 제어기를 설계하는 단계에서 해당 모델이 유용하게 사용될 수 있다. 제안된 모델의 타당성을 모의실험을 통해 확인하고 기존의 열전 냉각장치와 성능을 비교함으로써 응축수를 활용한 열전 냉각장치의 우수성 또한 검증한다.

RELAP5 Analysis of a Condensation Experiment in an Inverted U-tube

  • Park, Chul-Jin;Lee, Sang-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.383-388
    • /
    • 1995
  • Two-phase transient phenomena in the noncondensable gas-filled closed loop was investigated numerically using the RELAP5/MOD3 version 3.1 computer code. The condensation heat transfer correlation for noncondensable gases was studied in detail. Two modes of the reflux condensation which can be characterized by countercurrent flow of steam and its condensed water and the oscillatory between reflux condensation and natural circulation were predicted well. However, the natural circulation mode which the condensed water carried over the U-bend concurrently with steam was failed to predict.

  • PDF

Water Sorption/Desorption Kinetics and Convective Drying of Eucalyptus globulus Wood

  • AMER, Mahyoub;KABOUCHI, Bousselham;El ALAMI, Salah;AZIZE, Brahim;RAHOUTI, Mohamed;FAMIRI, Abderrahim;FIDAH, Abdelwahed
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.557-566
    • /
    • 2019
  • Radial and tangential water diffusion in Eucalyptus globulus wood was investigated using three mature trees from a forest in Khemis Sahel (North Morocco). Absorption and desorption kinetics experiments were conducted at ambient temperature ($25^{\circ}C$) and $30^{\circ}C$, respectively, and a relative humidity of 60%. The diffusion coefficients in the two directions were determined under imposed hygrothermal conditions; they were greater in the radial direction for the absorption as well as desorption processes. Convective drying under load, preceded by reconditioning and followed up by balancing, revealed the drying conditions that corresponded to the appropriate drying schedules for E. globulus wood. This was verified by measuring the cracks and bowsbefore and after drying of boards.

Condensed Molasses Solubles(CMS) / 당밀 혼합물이 반추위 미생물 단백질 합성량에 미치는 영향 (The Effects of Condensed Molasses Solubles(CMS) / Molasses Mixtures on Ruminal Microbial Protein Synthesis)

  • 여준모;정석근;김현섭;안병석;김창현;신형태
    • Journal of Animal Science and Technology
    • /
    • 제46권1호
    • /
    • pp.61-68
    • /
    • 2004
  • 본 연구는 monosodium glutamate의 생산 후 발생되는 부산물인 condensed molasses solubles(CMS)가 반추가축의 질소 공급원으로서 반추위 미생물 단백질 합성에 미치는 효과를 조사하기 위하여 수행하였다. 반추위 canulae가 부착된 4마리의 비착유소를 4 ${\times}$ 4 라틴 방각법에 적용하여 실험을 수행하였으며, 4개의 처리구는 다음과 같다. (1) 기초사료(앞착된 보리 3kg/일과 보리짚의 자유채식), (2) 기초사료에 당밀 200g/일 그리고 물 300g/일 첨가, (3) 기초사료에 당밀 200g/일, CMS 100g/일 그리고 물 200g/일 첨가 (4) 기초 사료에 당밀 200g/일, CMS 200g/일, 그리고 물 100g/일 첨가. CMS의 첨가수준에 따른 반추위내 발효양상은 처리구간에 유의적인 차이가 없었으나, CMS를 200g/일을 첨가한 처리구가 다른 처리구들에 비해 반추위내 미생물 단백질 합성량의 표시로서 이용된 allantoin/creatinine의 비율을 증가시키는 경향이 나타났다(P < 0.10).