• 제목/요약/키워드: Concrete resistivity

검색결과 133건 처리시간 0.022초

Analysis on IBEM for consideration on reinforced concrete slab resistance

  • Kyung, Je-Woon;Tae, Sung-Ho;Lee, Han-Seung;Lee, Sung-Bok
    • Computers and Concrete
    • /
    • 제5권6호
    • /
    • pp.545-558
    • /
    • 2008
  • The corrosion of RC structures demonstrates very complicated forms of deterioration intermingled together but all pointing to a decrease in the durability of RC structures due to the corrosion of reinforcing bars. Until now, nondestructive techniques, such as half-cell potential and polarization resistance, have been widely available in the world. The former provides information on the probability of corrosion while the latter is associated with information concerning corrosion rates. Inversion by the boundary element method (IBEM) was developed for considering concrete resistivity. The applicability of the procedure was examined through a numerical analysis and electrolytic tests for RC slabs. A distribution in such concrete resistivity is relatively inhomogeneous including cracks on the surface of slabs. Regarding cracks in concrete, the relative coefficient of concrete resistance was introduced to perform its analysis. Further, the procedure will be developed to identify the corroded region visually using 3-D VRML.

Utilization of Kota stone slurry powder and accelerators in concrete

  • Devi, Kiran;Saini, Babita;Aggarwal, Paratibha
    • Computers and Concrete
    • /
    • 제23권3호
    • /
    • pp.189-201
    • /
    • 2019
  • Recent advances in the concrete technology are aiding in minimizing the use of conventional materials by substituting by-products of various industries and energy sources. A large amount of stone waste i.e., dust and slurry form both are being originated during natural stone processing and causing deadily effects on the environment. The disposal problem of stone waste can be resolved effectively by using waste in construction industries. In present work, Kota stone slurry powder, as a substitution of cement was used along with accelerators namely calcium nitrate and triethanolamine as additives, to study their impact on various properties of the concrete mixtures. Kota stone slurry powder (7.5%), calcium nitrate (1%) and triethanolamine (0.05%) were used separately as well in combination in different concrete mixtures. Mechanical Strength, modulus of elasticity and electrical resistivity of concrete specimens of different mix proportions under water curing were studied experimentally. The durability properties in terms of strength and electrical resistivity against sulphate and chloride solution attack at various curing ages were also studied experimentally. Results showed that accelerators and Kota stone slurry powder separately enhanced the mechanical strength and electrical resistivity; but, their combination decreased strength at all curing ages. The durability of concrete specimens was also affected under the exposure to chemical attack too. Kota stone slurry powder found to be the most effective material among all materials. Material characterization was also done to study the microstructural properties.

IBEM analyses on half-cell potential measurement for NDE of rebar corrosion

  • Kyung, Je-Woon;Tae, Sung-Ho;Lee, Han-Seung;Alver, Yalcin;Yoo, Jo-Hyeong
    • Computers and Concrete
    • /
    • 제4권4호
    • /
    • pp.285-298
    • /
    • 2007
  • Corrosion of Reinforcement (rebar) is nondestructively estimated by the half-cell potential measurement. As is the case with other nondestructive testings (NDT), understanding of the underlying principles should be clarified in order to obtain meaningful results. Therefore, the measurement of potentials in concrete is analytically investigated. The effect of internal defects on the potentials measured is clarified numerically by the boundary element method (BEM). Thus, a simplified inversion by BEM is applied to convert the potentials on concrete surface to those on rebars, taking into account the concrete resistivity. Because the potentials measured on concrete surface are so sensitive to moisture content, concrete resistivity and surface condition, an inverse procedure to convert the potentials on concrete surface into those on rebars is developed on the basis of BEM. It is found that ASTM criterion is practically applicable to estimate corrosion from the potential values converted. In experiments, an applicability of the procedure is examined by accelerated corrosion tests of reinforced concrete (RC) slabs. For practical use, the procedure is developed where results of IBEM are visualized by VRML (Virtual Reality modeling Language) in three-dimensional space.

Electrical resistivity and capillarity of self-compacting concrete with incorporation of fly ash and limestone filler

  • Silva, Pedro;de Brito, Jorge
    • Advances in concrete construction
    • /
    • 제1권1호
    • /
    • pp.65-84
    • /
    • 2013
  • Electrical resistivity is a property associated with both the physical and chemical characteristics of concrete. It allows the evaluation of the greater or lesser difficulty with which aggressive substances penetrate the concrete's core before the dissolution of the passive film process and the consequent reinforcement's corrosion begin. This work addresses the capillary absorption of self-compacting concrete (SCC) with various types and contents of additions, correlating it with its electrical resistivity. To that effect, binary and ternary mixes of SCC were produced using fly ashes (FA) and limestone filler (LF). A total of 11 self-compactable mixes were produced: one with cement (C) only; three with C + FA in 30%, 60% and 70% substitution ratios; three with C + LF in 30%, 60% and 70% substitution ratios; four with C + FA + LF in combinations of 10-20%, 20-10%, 20-40% and 40-20% substitution ratios, respectively; and four reference mixes according to the LNEC E 464 specification, which refers to the NP EN 206-1 norm. The evaluation of the capillarity of the mixes produced was made through the determination of the water absorption by capillarity coefficient according to the LNEC E 393 specification. The electrical resistivity was evaluated using the European norm proposal presented by the EU-Project CHLORTEST (EU funded research Project under 5FP GROWTH programme) and based on the RILEM TC-154 EMC technical recommendation. The results indicate that SCC's capillarity is strongly conditioned by the type and quantity of the additions used. It was found that FA addition significantly improves some of the properties studied especially at older ages.

비저항추정모델을 이용한 실험체 크기의 영향에 대한 연구 (A Study on the Effect of Specimen Size using Resistivity Estimation Model)

  • 임영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.113-119
    • /
    • 2019
  • 본 연구는 전기비저항 측정시 실험체 크기에 따른 영향에 대해 비저항추정모델을 이용한 해석적 검토를 목적으로 한다. 실험에서는 콘크리트 실험체를 제작하여 전극 간격별 겉보기 비저항 측정하였다. 측정된 겉보기 비저항은 실험체 크기가 작아지고 외측(가장자리)에 가까울수록 겉보기 비저항치의 왜곡현상이 심해진다는 것을 확인할 수 있었다. 측정치와 해석치의 비교·분석 결과, 실험체 크기의 영향성 검토에 REM이 활용될 수 있을 것으로 기대된다.

구조체접지극 활용을 위한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Using of Structure Grounding Electrode)

  • 김성삼;정만길;최종규;고희석
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.40-45
    • /
    • 2007
  • 건축물의 기초를 구조체접지 및 대용접지극으로 활용하기 위한 기초실험으로 모형블록의 저항률 특성에 관해 검토하였다. 콘크리트와 몰탈의 모형블록을 제작 후 상온과 함수 상태에서 저항률을 측정하였으며, 저항률을 저감시키기 위해 접지저항 저감제를 혼합한 블록을 제작 하여 비교 하였다. 블록의 저항 값은 블록 저항률에 의해 가장 많은 영향을 받으며, 블록 저항률이 동일하거나 유사한 값일 때 대지저항률 값의 차이만큼 접지저항 값의 차이가 발생하였다.

전기비저항 측정을 이용한 콘크리트 응결시점 평가 (Setting Time Evaluation of Concrete Using Electrical Resistivity Measurement)

  • 이한주;임홍재
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.361-369
    • /
    • 2017
  • 고성능 콘크리트의 개발로 인해 다양해지는 배합비에 따라, 콘크리트 초기강도 발현 시점을 예측할 수 있는 응결시점에 대한 관심이 높아지고 있다. 기존의 콘크리트 응결시간 측정을 위해 사용되고 있는 관입저항시험은 습식체가름을 실시한 모르타르를 이용한 간접적인 측정법으로, 현장 타설된 콘크리트의 정확한 응결시간을 나타내기 어렵다. 따라서 콘크리트에 직접 측정이 가능한 초음파 속도 측정법, 수화열 측정법, 전기 임피던스 측정법 등 다양한 비파괴 평가 기법들이 제안되고 있다. 본 연구에서는 수화 반응에 따른 시멘트계 재료 내부 전기전도성 변화를 측정하는 4-전극법을 이용하여 콘크리트의 전기 비저항 측정 기법을 제안하고자 한다. 다양한 배합비에 따라 시멘트 페이스트, 모르타르, 콘크리트의 전기 비저항 측정을 실시하였으며, 배합 후 24시간 측정결과로부터 초기 전기비저항 값과 전기비저항 상승시기를 측정 변수로 제안하였다. 또한, 관입 저항 시험에 따른 초결, 종결 시점과의 비교 분석을 통해 콘크리트 응결시점 평가를 위한 제안 기법의 적용 가능성을 확인하였다.

탈수섬유시트 거푸집을 사용한 콘크리트의 특성에 관한 연구 (The Properties of Concrete with Permeability Liners("CON-SILK") on the Formwork)

  • 구봉근;서치호;유택동;박재성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.141-148
    • /
    • 2003
  • Concrete surface is a part that resists chiefly to carbonation by carbonic acid gas, affluence of rainwater and air, deterioration by freezing thawing, salt damage by seawater, and other chemical erosion etc. Therefore, this research analyzed physical characteristic and durable characteristic of concrete eliminated glut water and bubble of concrete surface using CON-SILK that is permeated with dehydration. As a research result, concrete using CON-SILK was improved, in comparison with concrete using general formwork, in physical performance and durability of concrete, as surface hardness, carbonation resistivity, and salt content permeation resistivity etc. Therefore, we could know that it is effective to use CON-SILK in performance elevation of concrete surface.

콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구 (Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage)

  • 이보미;오석훈;임은상
    • 지구물리와물리탐사
    • /
    • 제18권3호
    • /
    • pp.115-124
    • /
    • 2015
  • 수변 콘크리트 구조물의 누수 탐지를 위해 변형된 배열을 이용하여 전기비저항 탐사를 실시하였다. 전극을 수면에 설치하여 콘크리트 구조물에 대한 새로운 전기비저항 탐사 방식을 제안하였으며, 해석의 단순화를 위해 선형 전류 송신원을 전류전극으로 사용하였다. 마지막으로 전위차를 얻는 방법에 따라 변형된 3가지 전극 배열을 제안하였고, 동일열전위 배열(direct potential array), 평행열 전위 배열(parallel potential array), 횡단 전위 배열(cross potential array)로 명명하였다. 변형된 전기비저항 탐사법을 수치해석, 실내 모형실험, 현장탐사에 적용한 후 그 결과를 비교 분석하여 수변 콘크리트 구조물의 누수 탐지 기술로서의 적합성을 알아보았다. 비교 분석 결과 동일열 전위 배열, 평행열 전위 배열, 횡단전위 배열 모두 누수가 일어날 때, 누수지점에서 뚜렷한 전위차의 변화 양상을 보여 수변 콘크리트 구조물의 누수 탐지에 유용한 방법임을 확인하였다.

강섬유보강 콘크리트 세그먼트의 강섬유가 표면전기저항에 미치는 영향 (Effect of steel fibers on surface electric resistivity of steel fiber reinforced concrete for shield segment)

  • 문도영;이규필;장수호;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제13권6호
    • /
    • pp.557-569
    • /
    • 2011
  • 강섬유보강 콘크리트는 숏크리트와 쉴드터널 세그먼트 등에 널리 이용되는 건설재료이다. 강섬유와 이형철근이 동시에 보강된 콘크리트 구조물에서 강섬유와 철근의 부식은 장기적 내구성능에 영향을 미칠 수 있다. 그러므로 이러한 구조물의 부식 가능성과 침투성능에 대한 적정한 평가가 가능한 방법의 도출이 필요하다. 따라서 본 연구에서는 강섬유와 철근이 동시에 보강된 콘크리트의 부식평가방안에 대한 실험적 연구를 수행하였다. 강섬유의 혼입량, 이형철근의 부식유무 등을 변수로 실험체를 제작하였으며, 각 변수 등이 표면전기저항치에 미치는 영향을 분석하였다. 실험결과, 강섬유는 전류의 교란을 발생시켜 표면전기저항치를 크게 저하시키는 것으로 확인되었다. 또한 강섬유가 3% 이상 혼입이 되면, 내부 이형 철근의 부식상태 및 부식가능성에 대한 평가가 불가능한 것으로 판단된다.