• 제목/요약/키워드: Concrete resistivity

검색결과 133건 처리시간 0.08초

겉보기 비저항 측정에서 철근과 전극배치의 상대적 영향 분석 (Analysis of the Relative Effect of Rebar and Electrode Arrangement in the Measurement of Spparent Resistivity)

  • 임영철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.317-318
    • /
    • 2021
  • The effect of reinforcing bars embedded in concrete varies depending on the position of the electrode in the electrical resistivity measurement. In this study, the apparent resistivity according to the electrode arrangement is analyzed for each measurement angle. Through this, it is intended to be used to improve the accuracy of measurement in the concrete resistivity.

  • PDF

적용 전압 및 저항이 콘크리트의 염소이온 확산특성에 미치는 영향 (Effect of Applied Voltage and Resistivity on the Characteristics of Chloride Ions Diffusion in Concrete)

  • 임병탁;배수호;정영수;김진영;심은철;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.673-678
    • /
    • 2002
  • There are various methods for the electrochemical techniques to estimate diffusion coefficient of chloride ions in concrete, such as ASTM C 1202 test method, Andrade's method, Dhir's method, Tang's method, and etc. In the case of estimating diffusion coefficient of chloride ions in concrete by using these methods, applied voltage and resistivity nay exercise some influence on the characteristics of chloride ions diffusion. Thus. in this study, effect of applied voltage and resistivity on the characteristics of chloride ions diffusion in concrete were researched by applying voltage in 12V, 30V, and 60V, and by using resistivity in 0.2Ω and 1.0Ω, respectively. It can be concluded that diffusion coefficient of chloride ions are found to be increasing as the individual applied voltage and resistivity decrease, when water-cement ratio is constant.

  • PDF

접지전극을 고려한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Grounding Electrodes)

  • 고희석;김성삼;최종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.437-439
    • /
    • 2007
  • This paper was analyzed the resistivity change characteristic of mortar model block and concrete that was made earth electrode that's used concrete or basic concrete of building for 1 year. The early resistivity measurement value of concrete model block is higher than mortar model block. But after 1 year the resistivity measurement value of mortar model block is significantly higher than concrete model block. Because depends on time elapsed complete dryness factor of mortar model block that has not gravel is higher than concrete model block. And absorptance and function of mortar mode block was by far outstanding than concrete model block in the data for verification of the amount of contained water and the amount of dryness of mortar model block and concrete model block.

  • PDF

콘크리트 비저항 측정에서 주변 철근의 영향에 대한 실험적 연구 (Evaluating the Influence of Embedded Reinforcement on Concrete Resistivity Measurements)

  • 임영철
    • 한국건축시공학회지
    • /
    • 제23권5호
    • /
    • pp.519-526
    • /
    • 2023
  • 본 연구는 겉보기 비저항 측정에 포함되는 주변 철근의 영향을 파악하기 위해 단근과 복근을 매립한 콘크리트 실험체를 제작하였다. 실험체는 중심에서부터 0.03m, 0.04m, 0.05m의 위치에 단근 또는 복근을 배근하고, 겉보기 비저항 측정은 실험체별 정해진 위치까지 0.01m의 간격으로 실시하였다. 모든 실험체는 철근의 상부위치에서 겉보기 비저항이 최저치를 보였고 복근 실험체는 단근에 비해 배근 중심위치에서 낮은 측정치를 나타내며 주변 철근의 영향이 측정 결과에 반영되었음을 보였다. 또한 배근 간격이 넓을수록 철근의 위치가 명확하게 구분되는 것을 알 수 있었다.

구조체 접지에서 블록의 저항률 특성 (Resistivity Characteristic of Block in Structure Grounding)

  • 고희석;김주찬;정만길;김성상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.280-281
    • /
    • 2006
  • This paper was analyzed fundamental about electrical characteristic of concrete to practical use base of building as Substitution Ground Electrode and Artificial Ground Electrode. 1) Gravel or Sand has a function that makes increase Resistivity of Concrete and Cement has a function that makes decrease Resistivity of Concrete. 2) Moisture Increase Work is so hard because of dry of Block but the Resistivity was decreased when the moisture of Concrete Block was gradually increased. 3) According to the measurement result of moltar and concrete block, ratio relation of Resistance and Resistivity of each block was thirty-fold difference.

  • PDF

Influence of curing condition and carbonation on electrical resistivity of concrete

  • Yoon, In-Seok;Hong, Seongwon;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • 제15권6호
    • /
    • pp.973-987
    • /
    • 2015
  • The electrical resistivity of air-dried, saturated, and carbonated concretes with different mixture proportions was monitored to evaluate and quantify the influence of the age of the specimen, carbonation, and curing condition. After 28 days of curing, four prepared specimens were stored in a vacuum chamber with 5% $CO_2$ for 330 days to make carbonated specimens. Four of the specimens were placed in water, and four specimens were cured in air until the end of the experiments. It was observed that the electrical resistivity of the carbonated specimens increased as carbonation progressed due to the decrease of porosity and the increase of hydrated products. Therefore, in order to estimate the durability of concrete, its carbonation depth was used as the measurement of electrical resistivity. Moreover, an increase of electrical resistivity for air-dried and saturated concretes was observed as a function of age of the specimen. From the relationship between chloride diffusivity provided by Yoon et al. (2007) and the measurements of electrical resistivity, it is expected that the results well be of significant use in calibrating chloride diffusivity based on regular measurements of electrical resistivity during concrete construction.

Theoretical and experimental investigation of piezoresistivity of brass fiber reinforced concrete

  • Mugisha, Aurore;Teomete, Egemen
    • Computers and Concrete
    • /
    • 제23권6호
    • /
    • pp.399-408
    • /
    • 2019
  • Structural health monitoring is important for the safety of lives and asset management. In this study, numerical models were developed for the piezoresistive behavior of smart concrete based on finite element (FE) method. Finite element models were calibrated with experimental data collected from compression test. The compression test was performed on smart concrete cube specimens with 75 mm dimensions. Smart concrete was made of cement CEM II 42.5 R, silica fume, fine and coarse crushed limestone aggregates, brass fibers and plasticizer. During the compression test, electrical resistance change and compressive strain measurements were conducted simultaneously. Smart concrete had a strong linear relationship between strain and electrical resistance change due to its piezoresistive function. The piezoresistivity of the smart concrete was modeled by FE method. Twenty-noded solid brick elements were used to model the smart concrete specimens in the finite element platform of Ansys. The numerical results were determined for strain induced resistivity change. The electrical resistivity of simulated smart concrete decreased with applied strain, as found in experimental investigation. The numerical findings are in good agreement with the experimental results.

콘크리트내 섬유복합체 보강근이 표면저항치에 미치는 영향 (Effect of Composite Re-bars Embedded in Concrete on Surface Electrical Resistivity of Concrete)

  • 문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.212-218
    • /
    • 2011
  • 본 논문에서는 실험을 통해 섬유복합 보강근이 콘크리트 표면저항치에 미치는 영향을 고찰하였다. 본 실험에서 콘크리트의 표면저항치는 Wenner기법에 의하여 4probe 방식에 의하여 측정되었다. 이형철근과 국내에서 생산된 GFRP 보강근 및 CFRP 보강근이 사용되었으며, 비교를 위하여 무보강 실험체의 표면저항치도 측정되었다. 기존의 연구에 따르면, 내부에 보강된 이형철근에 의하여 저항치가 영향을 받게 되는데, 보강근의 위치, 깊이 및 보강방향에 의하여 영향을 받는 것으로 보고된바 있다. 본 논문에서는 노후된 콘크리트구조물의 보강재와 신설구조물의 철근을 대신하여 사용될 수 있는 GFRP 및 CFRP 보강근이 사용되었을 때, 표면저항치의 변화를 실험적으로 고찰하였으며, 이 결과는 향후 FRP가 사용된 구조물의 부식상태 파악을 위한 비파괴시험 결과에 대한 평가에 유용하게 사용될 수 있다.

콘크리트 층간비저항에 의한 철근의 부식환경 평가에 관한 연구 (A Study on the Evaluation of the Corrosive Environment of Reinforcement Bar by Concrete Layer Resistivity)

  • 임영철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2012
  • Deterioration factors such as CO2 and chloride ions cause steel corrosion in RC structures. The diffusion of these factors depends on the water content in concrete. To examine the moisture condition of concrete, this research considers the availability of the steel effect ratio, which is calculated by Resistivity Estimation Model (REM). It is concluded that the steel effect ratio is expected to be available as a quantitative evaluation method in the assessment of concrete layer resistivity.

  • PDF

강섬유 보강콘크리트의 강섬유 분산이 표면전기저항에 미치는 영향 (Effect of Steel Fiber Distribution in Steel Fiber-reinforced Concrete on Surface Electrical Resistivity)

  • 김성도;문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.106-113
    • /
    • 2013
  • 콘크리트의 투수성능을 평가하는 여러 가지 비파괴시험방법 중의 하나는 표면전기저항을 측정하는 것이다. 그러나 콘크리트내에 강섬유로 인한 판단의 오류가 발생할 수 있기 때문에 강섬유 보강콘크리트에 본 표면전기저항측정방법을 적용하기에는 한계가 있다. 본 연구에서는 강섬유보강 콘크리트의 강섬유 분산도가 표면전기저항에 미치는 영향을 실험적으로 고찰하였다. 3개의 정방형 및 원형 실험체의 4개면에서의 저항치를 3번 반복하여 측정하였으며, 서로 비교하였다. 측정결과에 의하면, 원형실험체를 이용한 실험결과가 정방형 실험체의 결과에 비하여 강섬유의 영향을 일관되게 나타내고 있는 것으로 확인되었다. 또한, 강섬유의 분산도는 강섬유 혼입량에 비하여 측정결과에 미치는 영향이 미미한 것으로 나타났다. 결론적으로, 표면전기저항측정을 이용한 비파괴 평가법은 0.5%까지의 강섬유를 포함한 SFRC의 투수성 평가에 적용될 수 있는 것으로 판단된다.