• Title/Summary/Keyword: Concrete member

Search Result 1,056, Processing Time 0.025 seconds

Analysis of the Behavior of Concrete Compressive Member with Various Cross-Sectional Shapes Strengthened by CFS (다양한 단면을 지닌 콘크리트 압축부재의 CFS 보강에 따른 거동해석)

  • 이상호;이민우;김장호;김진근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.605-610
    • /
    • 2002
  • The purpose of this study is to develop an analytic model which can describe the behavior or concrete compressive member strengthened by CFS(Carbon Fiber Sheet) with various cross-sectional shapes such as circular. square, and octagonal and various laminate angles. The failure criterion of laminated CFS is based on Tsai-Wu failure criterion. The stress strain model of confined concrete compressive member is based on an equation proposed by Mander. The effective lateral confining pressure is considered and modified according to various cross-sectional shapes. Octagonal cross-section shows the best results in the aspect of ductility, while circular does in compressive strengthening effects. In addition, [0/0/0/0] laminate in which the direction of fiber is parallel to the direction of principal stress shows the superior strength and ductility than other laminates. The analytic results show that strength and ductility of the analytic model depend on the cross-sectional shapes as well as the laminate angles.

  • PDF

The Study of Optimal Design of FRP-Concrete Composite Deck (FRP-콘크리트 합성 바닥판의 최적설계에 관한 연구)

  • 이현섭;조성배;박장호;신영석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.511-516
    • /
    • 2004
  • The objective of this study is to optimally design FRP-concrete members of a bridge structure. Using the GENESIS7.0 that is a commercial optimization program we performed an optimal design with design parameters that consist of height, width of FRP member, height of concrete. And we practiced an optimal design with the design variables, thickness of upper flange, bottom flange, and web. The results of these studies are summarized as follows : (1) Thickness of composite-concrete is proper at over loon (2) FRP member reaches the optimal section when the width of the FRP member is 20cm its height is 10cm and the height of the composite-concrete is 12cm.

  • PDF

Effects of Specimen Length on Flexural Compressive Strength of Concrete (콘크리트의 휨압축강도에 미치는 부재길이의 영향)

  • 김진근;이성태
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.579-584
    • /
    • 1999
  • In evaluating the ultimate strength of a section for a concrete flexural member, the effect of member length is not usually considered, even though the strength tends to decrease with increase of member length. In this paper the influence of specimen length on flexural compressive strength of concrete was evaluated. For this purpose, a series of C-shaped specimens subjected to axial compression and bending moment were tested using four different length-to-depth ratios(from 1, 2, 3 and 4) of specimens with compressive strength of 58 MPa. Results indicate that the reduction in flexural compressive strength with increase of length-to-width ratios was apparent. A model equation was derived using regression analyses on the experimental data. It was also founded that the effect of specimen length on ultimate strain was negligible, but its effect of the ultimate load and the displacement at center of specimen was distinct. Finally more general model equation is also suggested.

  • PDF

The Study on Compressive Behavior of Connection Member between Steel Pipe Pile and Concrete Footing (강관말뚝 기초 두부 연결부의 압축거동에 관한 연구)

  • Youn, IL-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.183-190
    • /
    • 2006
  • Generally, application of steel pile as deep foundation member needs specials requirement for the connection method between steel pipe and concrete footing. To investigate real compressive behavior of connection member between steel pipe pile and concrete footing, three specimens were tested with carefully designed experimental system. Main test variable is the connection method between steel pipe pile and concrete footing. The bolted bonding method and hook bonding method was considered as the connection method in this study. From the test results gained from experiment, it was conformed that two types of connection method have the almost same compressive resistance capacity. Therefore, we can conclude that these two connection methods can be used as the strengthening method to verify the compressive composite action of concrete and steel pipe pile.

  • PDF

Effects of Specimen Length on Flexural Compressive Strength of Concrete (부재의 길이가 콘크리트의 휨압축강도에 미치는 영향)

  • 김진근;이성태;이태규
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.63-71
    • /
    • 1999
  • In evaluating the ultimate strength of a section for a reinforced concrete flexural member, the effect of member length is not usually considered, even though the strength tends to decrease with increase of member length. In this paper the influence of specimen length on flexural compressive strength of concrete was evaluated. For this purpose, a series of C-shaped specimens subjected to axial compression and bending moment were tested using four different length-to-depth ratios (from 1,2,3 and 4) of specimens with compressive strength of 590 kgf/$\textrm{cm}^2$. Results indicate that for the region of h/c <3.0 the reduction in flexural compressive strength with increase of length-to-depth ratios was apparent. A model equation was depth of an equivalent rectangular stress block was larger than that by ACI. It was also founded that the effect of specimen length on ultimate strain was negligible. Finally more general model equation is also suggested.

A Study on Blasting Aspect of Steel Member and Concrete Member According to Separation distance of Explosives (폭약 이격에 따른 강판과 콘크리트 부재의 파괴양상 연구)

  • Yang, Hyung-Sik;Kim, Jung-Gyu;Ko, Young-Hun;Noh, You-Song;Shin, Myeong-Jin
    • Explosives and Blasting
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • TNT was blasted on the surface of steel plates and concrete block to study the effect of separation distance between object and charge. The equation of US Army Corps of Engineers turned out to be rather conservative. Effect of separation distance is larger for steel plate than concrete block. Steel plate cannot be cut by standard or more charge in the case of 2 cm separation while the concrete block can be crushed with the same distance.

Analysis of Inner Temperature in High Strength Concrete under Standard Temperature-time Curve (표준화재곡선에 의한 고강도 콘크리트 부재의 내부온도 예측)

  • Song, Hun;Lee, Sea-Hyun;Mun, Kyung-Ju;Do, Jeong-Yun;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.469-472
    • /
    • 2005
  • With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. There is therefore a need to precisely predict the deterioration and fire damage of the exposed member. Thus, this work estimated the temperature distribution inside a member taking into consideration of the thermal properties by means of finite element method(FEM). The estimation results in a little higher prediction value than the experimental value in surface layer and is almost coincident with the experiment as the heating depth increase. From this work it can be known that the simulation application of FEM using the thermal properties of concrete member in high temperature gives rise to the confident prediction in the prediction of temperature distribution.

  • PDF

Seismic Performance of In- Filled Steel-Concrete Composite Columns Using Fiber Analysis Method

  • Park, Jae-Young;Kim, Jin-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.427-430
    • /
    • 2005
  • The study for seismic characteristics of square concrete-filled steel tubular (CFT) columns is analytically conducted. For predicting the strength and ductility of CFT columns, fiber analysis technique is used. The analytical results show reasonable agreement with experiment results. The influence of the steel tube on the lateral response of CFT columns is studied for the evaluation of seismic performance.

  • PDF

Minimum Thickness of FRP Member Applicable to FRP-Concrete Composite Deck (FRP-콘크리트 합성 바닥판에 적용 가능한 FRP 부재의 최소 두께)

  • Cho, Keun-Hee;Park, Sung-Yong;Kim, Sung-Tae;Cho, Jeong-Rae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.317-320
    • /
    • 2006
  • In order to determine a minimum thickness of the pultruded GFRP panel as a structural member, some experimental studies were performed. GFRP tubes with 2mm, 4mm, 6mm thickness were manufactured by pultrusion process. First, coupon tests for finding mechanical properties were carried out. Comparisons between test results and analysis results based on classical laminate theory showed large differences in case of 2mm, 4mm specimens. The reason is that it is difficult to apply appropriate pultruding force and keep layered stitched fabric flat for the pultrusion process of complex shaped FRP member with small thickness. On the consequence, we decide 6mm as a minimum thickness of FRP member. Second, 4-point bending tests were performed and the results with compared with numerical analysis. The behavior of FRP tube can be exactly predicted by numerical analysis if buckling analysis is included.

  • PDF

Experimental Study on Tension Stiffening of RC Tension Members (철근콘크리트 인장부재의 인장강성에 관한 실험적 연구)

  • 이봉학;윤경구;장동일
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.4
    • /
    • pp.120-129
    • /
    • 1998
  • The tension stiffening in reinforced concrete member means increase of stiffness caused by the effective tensile stress between cracks and the tension softening behavior of concrete. This paper presents on the tensile behavior and tension stiffening of RC tension members. Direct tension tests were performed with a main experimental variables such as concrete strength, rebar diameter and strength. The tension stiffening was analyzed from the load-displacement relationship and was compared with ACI code, CEB model and the proposed by Collins & Mitchell. The results are as follows : The tension behaviors of RC members were quite different from those of bare bar and were characterized by loading and concrete cracking steps. The effect of tension stiffening decreased rapidly as the rebar diameter and strength increased, and the concrete strength increased. The proposed by Collins & Mitchell described well the experimental results, regardless of rebar types and concrete. But, ACI code and CEB model described a little differently, depending on the types. The effect of tension stiffening in RC member was the biggest near at concrete cracking step and decreased gradually to the bare bar's behavior as loading closed to the breaking point. Thus, tension stiffening in RC members should be taken into account when the load-deflection characteristics of a member are required or a precise analysis near the load of concrete clacking is needed.

  • PDF