• 제목/요약/키워드: Concrete floor slab

검색결과 176건 처리시간 0.026초

A novel approach for the definition and detection of structural irregularity in reinforced concrete buildings

  • S.P. Akshara;M. Abdul Akbar;T.M. Madhavan Pillai;Renil Sabhadiya;Rakesh Pasunuti
    • Structural Monitoring and Maintenance
    • /
    • 제11권2호
    • /
    • pp.101-126
    • /
    • 2024
  • To avoid irregularities in buildings, design codes worldwide have introduced detailed guidelines for their check and rectification. However, the criteria used to define and identify each of the plan and vertical irregularities are specific and may vary between codes of different countries, thus making their implementation difficult. This short communication paper proposes a novel approach for quantifying different types of structural irregularities using a common parameter named as unified identification factor, which is exclusively defined for the columns based on their axial loads and tributary areas. The calculation of the identification factor is demonstrated through the analysis of rectangular and circular reinforced concrete models using ETABS v18.0.2, which are further modified to generate plan irregular (torsional irregularity, cut-out in floor slab and non-parallel lateral force system) and vertical irregular (mass irregularity, vertical geometric irregularity and floating columns) models. The identification factor is calculated for all the columns of a building and the range within which the value lies is identified. The results indicate that the range will be very wide for an irregular building when compared to that with a regular configuration, thus implying a strong correlation of the identification factor with the structural irregularity. Further, the identification factor is compared for different columns within a floor and between floors for each building model. The findings suggest that the value will be abnormally high or low for a column in the vicinity of an irregularity. The proposed factor could thus be used in the preliminary structural design phase, so as to eliminate the complications that might arise due to the geometry of the structure when subjected to lateral loads. The unified approach could also be incorporated in future revisions of codes, as a replacement for the numerous criteria currently used for classifying different types of irregularities.

Limit load equations for partially restrained RC slabs

  • Olufemi, O.O.;Cheung, K.L.;Hossain, K.M.A.
    • Structural Engineering and Mechanics
    • /
    • 제19권1호
    • /
    • pp.1-20
    • /
    • 2005
  • The expertise required in the judicious use of nonlinear finite element (FE) packages for design-assistance purposes is not widely available to the average engineer, whose sole aim may be to obtain an estimate for a single design parameter, such as the limit load capacity of a structure. Such a parameter may be required for the design of a proposed reinforced concrete (RC) floor slab or bridge deck with a given set of geometrical and material details. This paper outlines a procedure for developing design-assistance equations for carrying out such predictions for partially restrained RC slabs under uniformly distributed loading condition, based on a database of FE results previously generated from a large number of 'numerical model' slabs. The developed equations have been used for predicting the peak loads of a number of experimental RC slabs having varying degrees of edge restraints; with results showing a reasonable degree of accuracy and low level of scatter. The simplicity of the equations makes them attractive and their successful use in the field of application reported in this paper suggest that the outlined procedure may also be extended to other classes of concrete structures.

융통성을 고려한 장수명 공동주택 디자인에 관한 연구 (A Study on the Adaptable Long Life Multi-dwelling Housing Design in Korea)

  • 김진희
    • 한국실내디자인학회논문집
    • /
    • 제15권6호
    • /
    • pp.172-177
    • /
    • 2006
  • Most of the Korean multi-dwelling houses have less than 20 years of lifespan. Because the environmental issues such as energy consumption, limited resources, and demolition waste problems became been more and more critical, we now need to focus on long lasting and adaptable buildings. Korean wall bearing apartment buildings are constructed with site cast concrete for core, exterior, and interior together with pipes varied, so when the buildings are old and life style of the users changes, it is difficult to maintain and renovate these buildings. In this study, to resolve the problems described above, two types of Korean long life multi-dwelling housing models which represent improved durability and adaptability responding user's needs and life style changes were proposed with various methods as follows: Either column and beam structure or flat slab structure was used to utilize space better. To make maintenance easier and renovation economical for both public space and each unit, plumbing pipes, ducts, and conduits were clustered at the cores and public corridors with access doors and light weight partitions with steel studs and raised floors or above-ceiling spaces were used in lieu of site cast concrete walls and floor slabs with varied pipes.

해운대 두산 위브 더 제니스 구조설계 (Structural Design And Analysis of Haeundae Doosan We've The Zenith)

  • 박기홍;박석진
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.93-98
    • /
    • 2008
  • 해운대 두산 위브 더 제니스는 부산시 해운대구 수영만에 인접한 매립지에 세워지는 건축물로서 현재 지하 터파기 및 일부 기초공사 진행 중인 건축물이다. 타워동의 주 용도는 주거용 건축물로 높이 300m, 층수 80층으로 이루어져 주거용 콘크리트 건축물로서는 동양 최대의 높이를 자랑하고 있다. 타워는 총 3개의 고충타워와 1개의 저층타워로 이루어져 있으며 지하 저층부 길이가 가로폭 230m, 세로폭 200m로 전체가 한 개의 덩어리로 이루어진 구조물이다. 횡력저항 시스템은 중앙의 $700{\sim}800mm$ 두께의 코어벽체가 4방향의 외곽으로 확장되어 있으며 슬래브 외곽주변을 철근콘크리트 기둥을 설치하여 건축적인 요구사항에 부합되면서 횡방향 하중에 아주 효율적으로 저항할 수 있도록 계획되었으며, 풍 진동에 대해서도 아주 만족스러운 결과를 가져다주었다. 슬래브 바닥 시스템은 두께 250mm인 플랫 플레이트를 적용하여 충고의 최소화 및 외주부의 테두리보나 드롭패널을 설치하지 않아 시공성 및 공기단축에 부합되도록 계획되었다. 시공 시 및 준공 후에도 지속적인 상시 모니터링 시스템을 구축하여 계측된 자료를 기준으로 구조물의 안전성과 사용성을 객관적으로 판단하고 검증할 수 있도록 하였다.

  • PDF

역사적 도심 내 현존하는 옛 건축물의 유형 및 분포 특성 - 청주시 성안동과 중앙동을 대상으로 - (Types and Distribution Characteristics of Old Buildings in Historic Urban Area of Cheongju, Korea - Focused on Seongan-dong and Jungang-dong -)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제24권4호
    • /
    • pp.59-66
    • /
    • 2022
  • This study is to investigate the old buildings that have been built more than 50 years ago, targeting the areas of Seongan and Jungang-dong, the historic urban area of Cheongju. Their types and distribution characteristics are as follows. 1) First, the old buildings existing in downtown Cheongju account for 21.4% of 1,070 out of the total 5,000 buildings. Among them, wooden buildings before the 1950s accounted for 60% of them, resulting in severe aging. 2) Second, by use, 728 detached houses and 276 neighborhood living facilities account for 93.8% of the total, with 16 offices and 12 religious facilities. By structure, there are wood 65%, masonry 30%, and reinforced concrete 5% (54 buildings). By number of floors, the first floor 90%, the second floor 7.3%, and the third floor or higher 2.7% (30 buildings). The roof material is 51.6% of earthenware, followed by slate, cement, and slab. 3) Third, the old buildings are scattered all over the streets, and are concentrated in Namju-dong, Nammun-ro 1-ga-dong, Seoun-dong, and Sudong at the foot of Uamsan Mountain, a former refugee village. Also old buildings are distributed in Seoun-dong and Seokgyo-dong where hanok(korean traditional houses) are concentrated, in Namju and Nammunro 1 ga-dong blocks connected by alleys, and in cul-de-sac all over the place.

RC슬래브의 처짐제어를 위한 상향긴장식 부분PT공법의 적용 (Applicability of Partial Post-Tension Method for Deflection Control of Reinforced Concrete Slabs)

  • 이득행;김강수;김상식;김용남;임주혁
    • 콘크리트학회논문집
    • /
    • 제21권3호
    • /
    • pp.347-358
    • /
    • 2009
  • 최근에 들어서 국내에서도 무량판 구조 (flat plate slab)가 적용될 수 있는 여건이 마련되어가고 있다. 그러나 무량판 구조는 보가 없는 구조이기 때문에 일반적인 라멘구조형식에 비하여 처짐 제어가 어려우며, 포스트텐션 (post-tension) 공법은 이러한 문제점을 극복하기 위한 매우 효율적인 방법이다. 포스트텐션 구조를 적용하면 슬래브 두께의 증가 없이도 효율적으로 슬래브의 처짐을 제어 할 수 있다. 그러나, 이러한 장점에도 불구하고, 국내에서 포스트-텐션의 적용은 비용증가, 기술적인 문제, 경험부족 등으로 인하여 그 적용이 매우 제한적이다. 따라서 전구간 포스트텐션 (full-PT)에 대한 부담을 줄이고 나아가 기존 포스트텐션 구조형식의 시공성을 향상하기 위하여 본 연구에서는 슬래브 내부에서 긴장작업을 수행할 수 있는 상향긴장식 부분PT공법을 제안하였다. 이러한 상향긴장방식은 정착구를 필요에 따라 다양한 위치에 설치할 수 있기 때문에 처짐 효율에 대한 분석이 필요하며, 정착구 후면에서 인장응력을 야기시키는 문제점이 있다. 따라서, 본 연구에서는 상향긴장식 부분PT공법 적용할 때 정착구 위치에 따른 처짐효율분석, 유한요소해석 및 스트럿-타이를 이용한 인장응력 또는 인장력 해석 등을 실시하였으며, 상향긴장식 부분PT공법을 실제로 현장에 적용하고, 계측결과를 해석결과와 비교 분석함으로써 현장적용성을 알아보았다. 상향긴장식 부분PT공법은 처짐 또는 인장응력이 크게 발생되는 부분 구간에만 선택적으로 적용하면 적은 비용증가로 큰 처짐효율을 얻어낼 수 있음을 확인하였다.

Inter-story pounding between multistory reinforced concrete structures

  • Karayannis, Chris G.;Favvata, Maria J.
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.505-526
    • /
    • 2005
  • The influence of the inter-story structural pounding on the seismic behaviour of adjacent multistory reinforced concrete structures with unequal total heights and different story heights is investigated. Although inter-story pounding is a common case in practice, it has not been studied before in the literature as far as the authors are aware. Fifty two pounding cases, each one for two different seismic excitations, are examined. From the results it can be deduced that: (i) The most important issue in the inter-story pounding is the local effect on the external column of the tall building that suffers the impact from the upper floor slab of the adjacent shorter structure. (ii) The ductility demands for this column are increased comparing with the ones without the pounding effect. In the cases that the two buildings are in contact these demands appear to be critical since they are higher than the available ductility values. In the cases that there is a small distance between the interacting buildings the ductility demands of this column are also higher than the ones of the same column without the pounding effect but they appear to be lower than the available ductility values. (iii) It has to be stressed that in all the examined cases the developed shear forces of this column exceeded the shear strength. Thus, it can be concluded that in inter-story pounding cases the column that suffers the impact is always in a critical condition due to shear action and, furthermore, in the cases that the two structures are in contact from the beginning this column appears to be critical due to high ductility demands as well. The consequences of the impact can be very severe for the integrity of the column and may be a primary cause for the initiation of the collapse of the structure. This means that special measures have to be taken in the design process first for the critically increased shear demands and secondly for the high ductility demands.

비보강 조적조의 동적 거동 (Dynamic Response of Unreinforced Masonry Building)

  • 김남희;김재관
    • 한국지진공학회논문집
    • /
    • 제8권5호통권39호
    • /
    • pp.1-14
    • /
    • 2004
  • 본 연구는 우리나라에서 저층 주거용 건물로 널리 사용되고 있는 2층 규모의 비보강조적조 의 1/3 축소 모델에 대한 진동대 실험을 수행한 것이다. 본 연구의 주목적은 내진설계가 이루어지지 않은 조적조 건물의 내진거동을 살펴보고, 실험적 자료를 확보하는데 있다. 실험대상구조물은 횡방향으로는 대칭이지만 종방향으로는 약간 비대칭이고, 비교적 강한 다이어프램을 나타내는 콘크리트 슬래브로 되어있다. 실험체에 대한 모의 지진하중은 가속도를 점차 증가시켜가면서 종방향으로 가력하였다. 실험에서 얻은 구조물의 동적 응답자료는 진동대의 입력지진과 연관지어서 분석하였다. 더욱이 성능기초설계를 위한 성능수준을 제시하였다. 실험결과 1층에서의 전단파괴가 지배적이고 상부층은 강체거동을 보여주었다. 또한 균열 발생후에도 상당한 강도와 변형능력을 보유하고 있는 것으로 나타났다.

친환경 층고 절감형 합성보의 보-기둥 접합부 상세 및 시공성 연구 (Environmental Friendly Connection of Composite Beams and Columns)

  • 홍원기;김진민;박선치;임선재
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.113-118
    • /
    • 2007
  • The composite beam adopted in the study was designed to reduce the floor height as well as to embed the top flange of steel frame into the slab that will enable to avoid applying the fire-resistant coating and to unify the joint method with a steel frame-type. As the steel frame and bottom concrete of the beam is pre-fabricated at the factory it could reduce the overall schedule at the jobsite. Applying such composite beam system to the work is expected to provide the efficient and enhanced performance, given the current tendency of the building construction that tends to be getting higher, larger and dense. The study focused on combining the composite beam with various column systems in a bid to propose the details thereof. A desirable composite girder can be adopted depending on site conditions through the evaluation of various beam and jointing approaches. Among the column systems applied to the study are steel column, SRC column, RC-PC column and RC column. The ways of combining with the columns addressed in the study were categorized into the rigid joint, pin joint, steel frame joint and bracket type joint. Besides, the instruction for site fabrication of beam-column was added in an effort to help set up the site fabrication procedures.

U-형 복합보의 춤 변화에 따른 구조성능에 관한 실험적 연구 (An Experimental study on the Structural Performance by the Depth Variation of Capacity of U-shaped composite Beam)

  • 하상수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.111-118
    • /
    • 2020
  • 본 연구에 사용된 U-형 복합보는 슬래브는 철근콘크리트구조로 되어 있고, 슬래브를 지지해 주는 보는 철골구조와 철근콘크리트구조, 그리고 U-형 강판으로 이루어져 있다. U-형 복합보는 시공성이 우수하고 낮은 층고와 장경간이 가능하기 때문에 공작물 주차장으로 사용하기 위한 목적으로 개발되었다. 시공성 향상을 위해 U-형 복합보 단부는 규격화된 H형강으로 계획하여 기둥에 직접 접합시키고, 강재 물량을 감소시키기 위해 U-형 복합보의 중간 부분에는 H형강 대신 얇은 강판(t=6)을 사용하여 U자형 형태로 접은 U-형 강판으로 구성되어 있다. U형 강판이 위치하는 복합보 중앙부에는 보의 춤을 작게 계획함으로서 공작물 주차장의 제한 높이에 만족하도록 계획할 수 있다. 낮은 보의 춤은 층고 단축에는 유리하지만 휨성능에는 저해 요인이 되기 때문에 춤 변화에 따른 구조성능을 파악하는 것이 중요하다. 또한, U-형 복합보는 철골구조와 철근콘크리트구조 및 U-형 강판이 혼합되어 있기 때문에 일체성 확보가 구조성능을 확보하는데 큰 영향을 준다. 따라서 본 연구에서는 U-형 복합보의 춤을 변화에 따른 구조성능을 파악하기 위한 구조실험을 실시하였다. 실험체는 일반주차장용으로 계획된 실험체를 기준실험체로 하여 춤을 변화시킨 2개의 실험체를 포함하여 총 3개를 계획하였다. 실험결과 춤을 크게 계획한 실험체가 기준실험체보다 항복강도, 최대강도, 에너지 등 구조성능이 우수하게 나타났다.