• 제목/요약/키워드: Concrete floor slab

검색결과 176건 처리시간 0.025초

콘크리트 강도에 따른 바닥판 수직진동에 대한 적정 두께 제안 (The Adequate Slab Thickness Satisfied with the Vertical Floor Vibration Criteria for Several Concrete Compressive Strength)

  • 남상욱;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.659-662
    • /
    • 2003
  • Recently, the floor thickness in residence may not be satisfied with the floor vibration criteria although the thickness is evaluated by the serviceability requirements in current design provisions. Thus it is necessary to develop the procedure to determine slab thickness satisfied with the floor vibration criteria. In this study, We proposed the methods to determine the slab thickness satisfied with the vertical floor vibration criteria for several concrete compressive strength of flat plate floor systems. For this purpose Monte Carlo simulation procedure was adopted and both randomness inherent in young modulus of concrete and heel drop intensity were accounted.

  • PDF

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가 (A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam)

  • 노영숙;윤성호
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

수직진동 사용성을 고려한 플랫 플레이트 슬래브의 최소두께 제안 (Minimum Thickness of Flat Plate Slab Satisfying Floor Vibration Criteria)

  • 이민정;김동현;한상환
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.574-581
    • /
    • 2006
  • Flat plate slab systems are more economical rather than reinforced concrete frame systems because flat plate slab system reduces story height. Furthermore flat plate systems are more popularly needed in construction practice due to flexibility of plan. Korean Concrete Provisions 2003 provide the minimum thickness of the slab that satisfies serviceability requirement to the static displacement. However, floor thickness in residence buildings may not satisfy the floor vibration criteria although the thickness satisfies the serviceability requirements in current design provisions. This study estimates the dynamic properties of floor vibration for existing flat plate slabs, and proposes the slab thickness satisfying the floor vibration criteria. The dynamic response analysis using finite element method and reliability analysis are carried out for this Purpose.

콘크리트 슬래브 압축강도에 따른 바닥충격진동 및 소음특성 (Floor Impact Sound and Vibration Characteristics Affected by the Compressive Strength of Concrete)

  • 정정호;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.796-799
    • /
    • 2005
  • In 2005, a regulation on the heavy-weight impact sound was released, which restricted concrete slab thickness of standard floor to 210mm. To reduce heavy-weight impact sound, damping materials and structural reinforcement system have been proposed. In this study, the effect of compressive strength on the heavy-weight impact vibration and sound were investigated. FEM analysis was conducted for the 34PY apartment with different concrete strength (210, 350, 420kg/cm$^2$). In addition, apartment floors with different concrete strength were constructed and the floor impact vibration and sound were measured. Results of FEM analysis and measurement show that the resonance frequency of concrete slab was increased by the increment of concrete strength. However, floor impact sound pressure level did not decrease because the nor impact vibration and sound pressure level in 63Hz band increased.

  • PDF

고무칩을 이용한 공동주택 바닥구조의 차음성능 향상에 관한 연구 (A Study on the Sound Insulation Performance Elevation of Floor Structure that use Rubber chip in Apartment House)

  • 박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.237-332
    • /
    • 2002
  • We constructed ceiling structure and floor structure for elevation of sound insulation performance of concrete slab of apartment house. And, we wished to measure heavy floor impact sound level and light floor impact sound level of these structure. As the result, light floor impact sound level interception performance of concrete slab was measured by thing that construction work of gypsum baud is important. Heavy floor impact sound level interception performance was measured by thing that it is effective that construct to thickness about 30 millimeters on concrete Slav. It was measured effectively that heavy floor impact sound level interception performance constructs rubber chip to thickness about 30 millimeters on concrete Slav.

  • PDF

수직진동 사용성 기준을 고려한 바닥판 두께 제안 (Probability Based Determination of Slab Thickness Satisfying Floor Vibration Criteria)

  • 이민정;남상욱;한상환
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.687-694
    • /
    • 2005
  • 건설 재료와 기술의 발달로 건축물이 장스팬화 ·경량화 되어 가고 있다. 이로 인해 건축물 바닥의 고유진동수(Frequency)와 감쇠비(damping ratio)가 감소함에 따라 거주자들의 바닥판의 수직진동에 대한 문제가 발생하고 있다 그러나 현행 사용성 기준은 바닥판의 최대 정적 처짐에 의해 결정하고 있다. 하지만 선행연구(Han et al., 2003)에서 현행 기준을 만족하는 바닥이 수직진동에 대한 사용성 기준을 만족하지 못하는 것을 볼 수 있다. 따라서 본 연구에서는 거주자들의 뒤꿈치 충격하중에 대한 수직진동 사용성 기준을 만족하는 바닥 두께를 제안하고자 하였다. 슬래브 재료의 특성과 뒤꿈치 충격하중 및 마감 고정하중의 불확실성을 고려하기 위해 Monte Carlo Simulation을 사용하여 확률적으로 접근하였다. 그 결과 4변 단순지지의 경우 두께가 스팬 길이의 $1/14\~1/17$에서, 4변 고정지지의 경우 스팬 길이의 $1/18\~1/25$인 경우에 초과 확률이$0\%$에 도달하였다.

공동주택의 바닥충격진동 저감을 위한 유한요소법 및 다구찌법의 활용 (Application of Finite Element Method and Taguchi Method to Reduce Floor Impact Vibration in Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.385-388
    • /
    • 2005
  • Finite element method and Taguchi method were used to reduce the floor impact vibration of the reinforced concrete slab in the apartment buildings. At first, experimental results show that sound peak components to influence the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab, and there is a high linear relation between floor impact vibration and sound. The tables of orthogonal arrays were used for finite element analysis with 5 factors related to slab shape parameters and its results were analyzed by statistical method. The most effective factor to reduce the floor impact vibration was the length of living/kitchen room and the floor impact vibration was predicted by 30% reduction in the acceleration peak by the optimal design values of the factors.

  • PDF

집중하중 조합에 의한 섬유 보강 콘크리트 바닥슬래브의 설계 휨 내력 (Effect of the Combination of Point Loads on the Design Flexural Capacity for Fiber Reinforced Concrete Floor Slab)

  • 이종한;조백순;김정식;조범구;김한식
    • 한국건설순환자원학회논문집
    • /
    • 제4권1호
    • /
    • pp.47-54
    • /
    • 2016
  • 본 연구에서는 섬유 보강 콘크리트 바닥슬래브의 주요 설계하중인 선반하중과 이동하중에 의한 휨 내력을 평가하였다. 설계기준을 바탕으로 각 하중의 크기와 작용면적을 정의하였으며, 그 관계를 분석하였다. 단일하중에 의해서는 슬래브 경계면에서 휨 내력이 평가되어야 하며, 슬래브 두께 180mm 이상, 콘크리트 강도 35MPa 이상일 때는 최소 등가 휨강도비로써 휨 내력을 충분히 만족하였다. 조합하중에 의해서는 선반하중간의 조합이 가장 큰 등가 휨강도비를 요구하였으며, 선반하중과 이동하중의 조합은 선반하중간의 조합에 비해서는 작게 평가되었고, 단일 하중에 비해서는 크게 평가되었다. 본 연구결과 섬유 보강 콘크리트 바닥슬래브의 휨 설계는 하중 조합에 의한 내력 평가가 필요함을 확인하였다.

시멘트계 SL재를 사용한 콘크리트슬래브 미장공법 (A finishing construction method for concrete floor and slab using the cement based self leveling mortar)

  • 손형호;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.387-392
    • /
    • 1994
  • Recently, as the problems according to lack of skilled labour and superior construction materials were gathering strength, there were required the advent of a special materials in building construction division. As a view of the point, the cement-based Self leveling mortar was developed for improvements of the former problems. The Self leveling mortar has the all kinds of the properties as followed the premixed products in plant, self-smoofhing, non shrinkgae etc, accordingly the finishing of concrete floor don't need skilled labour. The purpose of this study is to establish the introduction of a finishing construction method for concrete floor and slab using the cement-based self leveling mortar. Presented is a study on the basic properties of fresh and hardened self leveling mortar. To this end, an actual floor's finishing construction using the cement-based self leveling mortar was conducted in approximately 1,800㎡ floor as to compare the flatness and levelness after finighing.

  • PDF