• Title/Summary/Keyword: Concrete Test

Search Result 8,266, Processing Time 0.037 seconds

Influence of Compressive Strength of Concrete Affected by fixed test Specimens and moved test Specimens (운반된 공시체가 콘크리트의 압축강도에 미치는 영향)

  • 조일호;양재성;김성욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.957-960
    • /
    • 2000
  • The purpose of this study was performed to estimate the influence of compressive strength of the concrete according to change test specimens of concrete were investigated by measurements of slump, air content and compressive strength. As a result, according to moved test specimens, the compressive strength, fiexed test specimens effected on Concrete compressive strength, test specimens than moved test specimens, increased 4∼10% fixed test specimens, 2∼9% moved test specimens.

Evaluation for High Strength Concrete using Pullout Test (인발법을 이용한 고강도 콘크리트 구조물의 강도평가방법)

  • Ko, Hune-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.3
    • /
    • pp.85-91
    • /
    • 2008
  • Out of all the nondestructive test (NDT) methods, the pullout test is one of the most reliable techniques for estimating the strength of concrete under construction. However the pullout test inevitably produces significant surface damage because of the inherent test mechanism and costs too much for using measurement devices. In the view of construction engineers and inspectors, the main purpose of NDT methods for concrete is to verify whether the concrete strength of structure members exceeds the target strength or not. In this paper, a new pullout test method, which involves a pre-installed breaking bolt, with pre-determined breaking torques corresponding to the target strength of concrete, is introduced with related test data. The three types of test, the rebound hammer test, the pullout test, and the new pullout test with breaking bolt, were carried out on wall specimen with three types of concrete strengths. Our results show that concrete strength as evaluated by the pullout test with breaking bolt was similar with cylinder test results. Therefore it can be said that the new pullout test with breaking bolt is a useful method for checking the concrete strength without any surface damages in construction site.

An Experimental Research on the Material Properties of Super Flowing Concrete (초유동 콘크리트의 재료특성에 관한 실험적 연구)

  • 김진근;한상훈;박연동;노재호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.56-62
    • /
    • 1995
  • In this study, the properties of super flowing cocrete containing gly ash were experimentally investigated and compared with those of ordinary concrete. Tests were carried out on five types of super flowing concrete mixes containing fly ash and three types of ordinary concrete mixes without fly ash. Flow test, O-funnel test, box test, Ltype thest and slump test were carried out to obtain the properties for the workability of fresh concrete. Compressime strength, splitting tensile strength, modulus of elasticity. creep and shrinkage test were also obtained as the mechanical properties of hardened concrete. In fresh concrete, it was found that super flowing concrete had excellent workability and flowability compared with ordinary concrete, and the volume ratio of coarse aggregate to concrete volume greatly influenced flowability. Super flowing concrete also had good mechanical properties at both early and late ages with compressive strengths reaching as high as 40 MPa at 28 days. The creep deformation of super flowing concrete investigated were relatively lower than that of ordinary concrete.

  • PDF

Comparision of Test Methods for Estimating Chloride Ion Diffusion Coefficient in Concrete (콘크리트중의 염소이온 확산계수 추정 실험법의 비교)

  • 문한영;김홍삼;문재흠;한아름
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.787-790
    • /
    • 1999
  • To estimate durability of reinforced concrete structures located in or nearby seawater, many different kinds of accelerated tests for evaluation of chloride ion permeation in concrete were proposed. At present the only standardized test is the ASTM C 1202(RCP test). This test method is used to estimate the concrete's resistivity of the chloride penetration in concrete by using the total charges passed and sometimes used to calculate the chloride diffusion coefficients. However, this test may lead to an erroneous chloride diffusion coefficient. So this test method was compared with the modified Dhir's test and the traditional concentration diffusion test. Experimental results showed that the diffusion coefficients determined the RCP test and the PD Index gave wrongous values, but the diffusion coefficient acquired by considering a migration term was nearly the same to the CD Test.

  • PDF

Experimental Study on the Development of High-Performance Concrete (Properties of Super-flowing Concrete) (고성능 콘크리트 개발에 관한 실험적 연구(제2보, 초유동 콘크리트의 기초물성))

  • 조일호;한정호;정재동
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.51-56
    • /
    • 1993
  • This is a part a study on the development of High-Performance Concrete ; about experimental results from several test methods to estimate workability in fresh concrete and influences of concrete mix design that affects properties of super-flowing concrete. Super-flowing concrete can be filled in a formwork without any vibration because of its excellent workability of passing narrow space and filling complicated shaped mold, new test methods should be used to estimate the workability and rhelogy in super-flowing concrete instead of slump test method in conventional concrete.

  • PDF

A Fundamental Study on the Development of Fire Resistance Filling of Friendly Environment Using Aerated Concrete (기포콘크리트를 이용한 친환경 내화충전제개발에 관한 기초적 연구)

  • Lee, jong-il;Lim, Nam-Gi
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.119-126
    • /
    • 2007
  • In this study, we processed two procedures of application test of filler for fire-resistance utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

An Experimental Study on the Bond Split Mechanism of High Strength Concrete (고강도 콘크리트의 부착할렬기구에 관한 실험적 연구)

  • 장일영
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.4
    • /
    • pp.129-136
    • /
    • 1999
  • For the prediction of concrete-steel bond ability in reinforced concrete, many countries establish specifications for the pullout test. But these methods hardly to consider many parameters such as strength, shape, diameter and location of steel, concrete restrict condition by loading plate, strength of concrete and cover depth etc, and it is difficult to solve concentration and disturbance of stress. The purpose of this study is to propose a New Ring Test method which can be rational quantity evaluations of bond splitting mechanism. For this purpose, pullout test was carried out to assess the effect of several variables on bond splitting properties between reinforcing bar and concrete. Key variables are concrete compressive strength, concrete cover, bar diameter and rib spacing. Failure mode was examined and maximum bond stress-slip relationships were presented to show the effect of above variables. As the result, it appropriately expressed general characteristics of bond splitting mechanism, and it proved capability for standard test method.

Strength Prediction Equations of High Strength Concrete by Schmidt Hammer Test (슈미트 해머 시험법에 의한 고강도 콘크리트의 강도 추정식)

  • Park Song Chul;Yoo Jae Eun;Kim Min Su;Kwon Young Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.615-618
    • /
    • 2005
  • This study concerns the equation of high strength concrete by schmidt hammer test. There are not only few prediction strength equations of concrete by schmidt hammer test, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. For this study, there performed a series of schmidt hammer test with in existing 1,095days' concrete structures and proposed equations as follows ; Linear: ${\Large f}_{ck}=-45.35+2.44R(r^2=72.7\%)$ Quadratic: ${\Large f}_{ck}=-502.08+24.0R-0.25R^2(r^2=82.4\%)$ here, $f_{ck}$ : Estimated compressive strength of concrete by MPa, R : Rebound index of concrete

  • PDF

An Experimental Study on the Creep and Shrinkage for the Segment Concrete in PSC Box Girder Bridge (PSC 박스거더 교량에 사용된 세그먼트 콘크리트의 크리프 및 건조수축에 관한 실험적 연구)

  • 최한태;윤영수;이만섭
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.23-34
    • /
    • 1999
  • In designing PSC box girder bridge, the dead load, prestressing force, creep and shrinkage of concrete are the main factors which influence the camber and deflection of segmental concrete structure under construction. Among these factors the creep and shrinkage are the functions of the time-dependent property which, therefore, must considered with time. The prediction model for estimating creep and shrinkage of concrete has been suggested by ACI, CEB/FIP, JSCE and KSCE design code. In this study the creep and shrinkage test were carried out for four curing ages of concrete which was applied to the pretressed concrete box-girder bridge at a construction site, and the results of test were compared to the values of prediction by the design code. Shrinkage test shows that the test results are similar to KSCE-96 and JSCE-96 but very higher than other prediction model and creep test results are generally similar to ACI-209 and DSCE-96 but lower than other prediction models in contrast to shrinkage test.

A New Strength Equation of Concrete by Schmidt Hammer Test (슈미트햄머 시험법에 의한 콘크리트 강도 추정식)

  • Park Song-chul;Yoo Jae-Eun;Kim Min-Su;Kwon Young-Wung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.133-136
    • /
    • 2004
  • This study concerns the. new equation of concrete strength by schmidt hammer test. There are not only few estimate strength equations of concrete by schmidt hammer test, but also many problems to apply them because of time, cost, easiness, structural damage, reliability and so on. For this study, there performed a series of schmidt hammer test with in existing 730days' concrete structures and proposed equations as follows; $$Linear\;:\;f_{ck}=2.18R-40.54\;(r^2=77.7\%)$$ $$Quadratic\;:\;f_{ck}=0.076R^2-2.92R+40.04\;(R^2= 85.5\%)$$ here, fck : Estimated compressive strength of concrete by MPa, R : Rebound index of concrete.

  • PDF