• 제목/요약/키워드: Concrete Mix Proportions

검색결과 225건 처리시간 0.03초

수화열 해석프로그램을 이용한 기초 매스콘크리트의 사전 배합선정 및 수화열 검토 (Study on Hydration Heat and Contact the Mix-Design of Foundation Mass Concrete Using Hydration Temperature Analysis Program)

  • 설준환;조만기;방홍순;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2019
  • In this research, considering the practical conditions at field, thermal cracking method was suggested based on the comparative analysis between predicted value and actual value obtained from the actual structure member with optimum mix design. The optimum mix design was deduced from the various mix designs with various proportions of cementitious binder for upper and lower placement lifts of mat-foundation mass concrete. Therefore, it can be stated that applying low heat mix design and different heating technique between upper and lower placement lifts for mass concrete are efficient to control the thermal cracking. As future issues, based on the interpretation result value, we will select the optimal combination that is applied specifically to the actual site, and deeply analyze the correlation between the measured value and the analysis value through the combination and the test of the actual structure.

  • PDF

Experimental Study on the Shrinkage Properties and Cracking Potential of High Strength Concrete Containing Industrial By-Products for Nuclear Power Plant Concrete

  • Kim, Baek-Joong;Yi, Chongku
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.224-233
    • /
    • 2017
  • In Korea, attempts have been made to develop high strength concrete for the safety and design life improvement of nuclear power plants. In this study, the cracking potentials of nuclear power plant-high strength concretes (NPP-HSCs) containing industrial by-products with W/B 0.34 and W/B 0.28, which are being reviewed for their application in the construction of containment structures, were evaluated through autogenous shrinkage, unrestrained drying shrinkage, and restrained drying shrinkage experiments. The cracking potentials of the NPP-HSCs with W/B 0.34 and W/B 0.28 were in the order of 0.34FA25 > 0.34FA25BFS25 > 0.34BFS50 > 0.34BFS65SF5 and 0.28FA25SF5 >> 0.28BFS65SF5 > 0.28BFS45SF5 > 0.28 FA20BFS25SF5, respectively. The cracking potentials of the seven mix proportions excluding 0.28FA25SF5 were lower than that of the existing nuclear power plant concrete; thus, the durability of a nuclear power plant against shrinkage cracking could be improved by applying the seven mix proportions with low cracking potentials.

RCC 댐 콘크리트의 배합비 도출에 관한 연구 (Mix proportions of Concrete for Roller Compacted Concrete Dam Application)

  • 원종필;윤종환;황금식;장필성;김완영;정우성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.997-1002
    • /
    • 2003
  • Roller-compacted concrete(RCC) dam is a new type that combines advantages of earthfill dam and concrete dam in construction, This method save cost due to their rapid method of construction. RCC is, used in RCC dams, no-slump concrete so it is different that measure method of consistency and mixture properties compare with conventional mass concrete, There are existing two major design method, which one used in USA the other used in Japan. The results obtained in this study would be useful in establishing mixture proportions for dam concrete for RCC dams by apply method of compound their merit.

  • PDF

전기비저항 측정을 이용한 콘크리트 응결시점 평가 (Setting Time Evaluation of Concrete Using Electrical Resistivity Measurement)

  • 이한주;임홍재
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.361-369
    • /
    • 2017
  • 고성능 콘크리트의 개발로 인해 다양해지는 배합비에 따라, 콘크리트 초기강도 발현 시점을 예측할 수 있는 응결시점에 대한 관심이 높아지고 있다. 기존의 콘크리트 응결시간 측정을 위해 사용되고 있는 관입저항시험은 습식체가름을 실시한 모르타르를 이용한 간접적인 측정법으로, 현장 타설된 콘크리트의 정확한 응결시간을 나타내기 어렵다. 따라서 콘크리트에 직접 측정이 가능한 초음파 속도 측정법, 수화열 측정법, 전기 임피던스 측정법 등 다양한 비파괴 평가 기법들이 제안되고 있다. 본 연구에서는 수화 반응에 따른 시멘트계 재료 내부 전기전도성 변화를 측정하는 4-전극법을 이용하여 콘크리트의 전기 비저항 측정 기법을 제안하고자 한다. 다양한 배합비에 따라 시멘트 페이스트, 모르타르, 콘크리트의 전기 비저항 측정을 실시하였으며, 배합 후 24시간 측정결과로부터 초기 전기비저항 값과 전기비저항 상승시기를 측정 변수로 제안하였다. 또한, 관입 저항 시험에 따른 초결, 종결 시점과의 비교 분석을 통해 콘크리트 응결시점 평가를 위한 제안 기법의 적용 가능성을 확인하였다.

Wet-mix Shotcreting Application of High Ductile Fiber Reinforced Mortar Designed by Optimizing Mix Proportion

  • 김윤용;김정수;김진근;하기주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.581-584
    • /
    • 2004
  • High ductile fiber reinforced mortar suitable for wet-mix shotcreting (sprayable ductile mortar) 10 the fresh state, while maintaining tensile strain-hardening behavior in the hardened state, has been developed based on micromechanics and workability control. In the development concept of sprayable ductile mortar, micromechanics is adopted to properly select the matrix, fiber, and interface properties to exhibit strain hardening and multiple cracking behaviors in the composites. Within the pre-determined micromechanical constraints, the workability is controlled by optimizing mix proportions. A series of spray tests show the excellent pumpability and sprayability of the sprayable ductile mortar. Subsequent direct tensile tests demonstrate that the tensile performance of sprayed mortar is comparable to that of cast mortar, for the same mix design.

  • PDF

Temperature Reduction of Concrete Pavement Using Glass Bead Materials

  • Pancar, Erhan Burak;Akpinar, Muhammet Vefa
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.39-46
    • /
    • 2016
  • In this study, different proportions of glass beads used for road marking were added into the concrete samples to reduce the temperature gradient through the concrete pavement thickness. It is well known that decreasing the temperature gradient reduces the risk of thermal cracking and increases the service life of concrete pavement. The extent of alkali-silica reaction (ASR) produced with partial replacement of fine aggregate by glass bead was investigated and compressive strength of concrete samples with different proportion of glass bead in their mix designs were measured in this study. Ideal results were obtained with less than 0.850 mm diameter size glass beads were used (19 % by total weight of aggregate) for C30/37 class concrete. Top and bottom surface temperatures of two different C30/37 strength class concrete slabs with and without glass beads were measured. It was identified that, using glass bead in concrete mix design, reduces the temperature differences between top and bottom surfaces of concrete pavement. The study presented herein provides important results on the necessity of regulating concrete road mix design specifications according to regions and climates to reduce the temperature gradient values which are very important in concrete road design.

고성능 감수제를 사용한 쇄석 콘크리트의 유동화 성능 및 공학적 특성에 관한 연구 (An Experimental Study on the Fluidity Performance and Engineering Properties of Crushed Stone Concrete Using Superplasticizers)

  • 송하영;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.16-19
    • /
    • 1990
  • The effect of superplasticizers on the fluidity performance in fresh concrete and physical properties in hardened concrete have been analyzed and investigated under mix proportions of water cement ratio of 0.4, 0.6, crushed stone aggregates, and addition rates of superplasticizers of 0.0, 0.5, 1.0 and 1.5 in the practical range. It is the aim of this study to provide the fundamental data on the workability improvement and engineering properties of crushed stone concrete using superplasticizers comparing with conventional concrete for the practical use and research data accumulation of superplastized concrete.

  • PDF

CSA 팽창재를 사용한 무수축 콘크리트 현장적용사례 연구 (Practical Application of Nonshrinkage Concrete Using CSA Expansive Additive)

  • 김병권;조동원;김상용;신영인
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.620-626
    • /
    • 1997
  • In this study. use if CSA expansive additive for concrete is discussed, particulary applications to partial compacting the concrete structure of spillway gate located in Youngjong new airport construction field. Before the field applications, several basic laboratory test were carried out in order to clarify the material characteristics and to decide mix proportions. As the result the concrete using CSA expansive additive show similar workability and compressive strength to that of OPC concrete. Forethemore, it can be concluded that the use of CSA component is effective to prevent shrinkage crack and to achive volume stabiliy of concrete structure.

  • PDF

Pull-out behaviour of recycled aggregate based self compacting concrete

  • Siempu, Rakesh;Pancharathi, Rathish Kumar
    • Computers and Concrete
    • /
    • 제21권3호
    • /
    • pp.249-259
    • /
    • 2018
  • The use of recycled aggregate in concrete is gaining much attention due to the growing need for sustainability in construction. In the present study, Self Compacting Concrete (SCC) is made using both natural and recycled aggregate (crushed recycled concrete aggregate from building demolished waste) and performance of recycled aggregate based SCC for the bond behaviour of reinforcement is evaluated. The major factors that influence the bond like concrete compressive strength (Mix-A, B and C), diameter of bar ($D_b=10$, 12 and 16 mm) and embedment length of bar ($L_d=2.5Db$, $5D_b$ and full depth of specimen) are the parameters considered in the present study in addition to type of aggregates (natural and recycled aggregates). The mix proportions of Natural Aggregate SCC (NASCC) are arrived based on the specifications of IS 10262. The mix proportions also satisfy the guidelines of EFNARC. In case of Recycled Aggregate SCC (RASCC), both the natural coarse and fine aggregates are replaced 100% by volume with that of recycled aggregates. These mixes are also evaluated for fresh properties as per EFNARC. The hardened properties like compressive strength, split tensile strength and flexural strength are also determined. The pull-out test is conducted as per the specifications of IS 2770 (Part-1) for determining the bond strength of reinforcement. Bond stress versus slip curves were plotted and a typical comparison of RASCC is made with NASCC. The fracture energy i.e., area under the bond stress slip curve is determined. With the use of recycled aggregates, reduction in maximum bond stress is noticed whereas, the normalised maximum bond stress is higher in case of recycled aggregates. Based on the experimental results, regression analysis is conducted and an equation is proposed to predict the maximum bond stress of RASCC. The equation is in good agreement with the experimental results. The available models in the literature are made use to predict the maximum bond stress and compare the present results.

고성능 콘크리트 현장 시험시공 (Field test of high-performance concrete)

  • 신동수;노재호;박연동;권영호;한정호;조일호;백명종
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1995
  • In recent years, Hith Performance Concrete has attracted world wide attention for its workability, strength and long-term durability. A field test was conducted to confirm the properties of high performance Concrete in situconditions. This paper describes the concrete materials, mix proportions, fresh state properties, some aspects of placability and qualty control results for field test. From the result, it was found that it is possible to produce High Performance Concrete with self-compactable and high strength.

  • PDF