• 제목/요약/키워드: Concrete Layer Resistivity

검색결과 4건 처리시간 0.018초

콘크리트 층간비저항에 의한 철근의 부식환경 평가에 관한 연구 (A Study on the Evaluation of the Corrosive Environment of Reinforcement Bar by Concrete Layer Resistivity)

  • 임영철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2012
  • Deterioration factors such as CO2 and chloride ions cause steel corrosion in RC structures. The diffusion of these factors depends on the water content in concrete. To examine the moisture condition of concrete, this research considers the availability of the steel effect ratio, which is calculated by Resistivity Estimation Model (REM). It is concluded that the steel effect ratio is expected to be available as a quantitative evaluation method in the assessment of concrete layer resistivity.

  • PDF

Impact of aggressive exposure conditions on sustainable durability, strength development and chloride diffusivity of high performance concrete

  • Al-Bahar, Suad;Husain, A.
    • Structural Monitoring and Maintenance
    • /
    • 제2권1호
    • /
    • pp.35-48
    • /
    • 2015
  • The main objective of this study is to evaluate the long-term performance of various concrete composites in natural marine environment prevailing in the Gulf region. Durability assessment studies of such nature are usually carried out under aggressive environments that constitute seawater, chloride and sulfate laden soils and wind, and groundwater conditions. These studies are very vital for sustainable development of marine and off shore reinforced concrete structures of industrial design such as petroleum installations. First round of testing and evaluation, which is presented in this paper, were performed by standard tests under laboratory conditions. Laboratory results presented in this paper will be corroborated with test outcome of ongoing three years field exposure conditions. The field study will include different parameters of investigation for high performance concrete including corrosion inhibitors, type of reinforcement, natural and industrial pozzolanic additives, water to cement ratio, water type, cover thickness, curing conditions, and concrete coatings. Like the laboratory specimens, samples in the field will be monitored for corrosion induced deterioration signs and for any signs of failureover initial period ofthree years. In this paper, laboratory results pertaining to microsilica (SF), ground granulated blast furnace slag (GGBS), epoxy coated rebars and calcium nitrite corrosion inhibitor are very conclusive. Results affirmed that the supplementary cementing materials such as GGBS and SF significantly impacted and enhanced concrete resistivity to chloride ions penetration and hence decrease the corrosion activities on steel bars protected by such concretes. As for epoxy coated rebars applications under high chloride laden conditions, results showed great concern to integrity of the epoxy coating layer on the bar and its stability. On the other hand corrosion inhibiting admixtures such as calcium nitrite proved to be more effective when used in combination with the pozzolanic additives such as GGBS and microsilica.

접지봉 설치에 따른 전주 주변의 전위분포 (Potential Distribution near Concrete Pole According to the position of Ground Rod)

  • 이복희;정현욱;최종혁;조성철;백영환;이규선;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.342-346
    • /
    • 2006
  • This paper describes ground surface potential rises and touch voltage. The more soil resistivity of upper layer is lower, the more ground surface potential rise is increased. Ground surface potential rise is increased as the buried depth of ground rod in lowered. Ground surface potential rises were measured in the test site and compared with results by CDEGS program. Touch voltages according to the separation distance of ground rod were measured in four directions. Touch voltages were remarkably changed by separation distance and contact position.

  • PDF

광물찌꺼기적치장의 안전관리를 위한 적정 모니터링 방안 연구 (Proper Monitoring Methods for Safety Management of Tailings Dam)

  • 정명채;김정욱;황인호;양인재;박제현;박주현;김대엽
    • 한국자원공학회지
    • /
    • 제55권6호
    • /
    • pp.576-587
    • /
    • 2018
  • 광물찌꺼기적치장 안전 모니터링을 위한 적치장 안전에 영향을 미치는 요소를 분석하고 이러한 요소를 감시할 수 있는 계측장비를 검토하였다. 또한, 이러한 결과를 국내 광물찌꺼기 적치장(20개소, 18개 광산)에서 발생되는 결함에 대해 적용 가능한 계측장비를 선정하였다. 요소분석은 표면 침식, 파이핑 및 사면 불안정으로 구분하여 평가하였으며, 이를 다시 세분하여 표면 침식은 식생, 복토층 및 광물찌꺼기, 파이핑은 차수층, 우수배제시설 및 침출수, 사면불안정은 사면, 콘크리트 옹벽 및 석축으로 구분하여 결함의 지표 및 계측항목을 설정하였다. 계측은 주로 상시 및 변위계측이 가능한 CCTV의 활용이 높게 평가되었으며, 전기비저항탐사, 음향계측기, 다점온도모니터링, 구조물경사계, 강우량계 및 유량계 등의 활용도가 높은 것으로 평가되었다. 또한, 국내 적치장에서 발생되는 결함에 적용한 결과, 주로 파이핑과 관련된 차수층, 우수배제시설 및 침출수에서 결함이 주로 발견되어 이와 관련된 계측장비의 활용이 높은 것으로 평가되었다.