1 |
AASHTO T-259. (2002), Resistance of Concrete to Chloride Ion Penetration, Standard Specification for Transportation Materials and Methods of Sampling and Testing, 14th Ed., Washington DC, USA: American Association of State Highway and Transportation Officials.
|
2 |
Abdul-Salam, S. and Husain, A. (2013), Assessment Of The Durability And Corrosion Behavior Of Concrete Treated With Chemical Inhibitors For Kuwait Oil Company (KOC), Proposal, Kuwait Institute for Scientific Research, Kuwait.
|
3 |
Al-Bahar, S., Husain, A., Abdul-Salam, S., Abduljaleel, A., Karam, H. Al-Shamali, O. (2002), Evaluation of Selected Corrosion Protection Systems for Reinforced Concrete Structures in Kuwait, Final Report, KISR 6491, Kuwait Institute for Scientific Research, Kuwait.
|
4 |
Alhozaimy, A., Hussain, R.R., Al-Zaid, R. and Al-Negheimish, A. (2012), "Investigation of severe corrosion observed at intersection points of steel bars mesh in reinforced concrete construction", Constr. Build. Mater., 37, 67-81.
DOI
ScienceOn
|
5 |
Al-Matrouk, F., Al-Hashem , A., Al-Kharafi, F.M. and El-Khafif, M. (1996), "Impact of metallic corrosion on the Kuwait economy before and after the Iraqi invasion: A case study". In Industrial corrosion and Corrosion Control Technology: Proceedings of the Second Arabian Corrosion Conference, Kuwait: Kuwait Institute for Scientific Research.
|
6 |
Andrade, C. and Martinez, I. (2010), Techniques For Measuring The Corrosion Rate (Polarization Resistance) and the Corrosion Potential of Reinforced Concrete Structures, Non-Destructive Evaluation of Reinforced Concrete Structures, Non Destructive Testing Methods , ISBN:978-1-84569-950-5, 2, 284-316.
|
7 |
Ann, K.Y., Jung, H.S., Kim, H.S., Kim, S.S. and Moon, H.Y. (2006), "Effect of calcium nitrite-based corrosion inhibitor in preventing corrosion of embedded steel in concrete", Cement Concrete Res., 36(3), 530-535.
DOI
ScienceOn
|
8 |
ASTM C 876. (2009), Standard test method for half-cell potentials of uncoated reinforcing steel in concrete, American Society for Testing and Materials, Philadelphia, Pennsylvania.
|
9 |
ASTM C 1202. (2012), Electrical indication of concrete's ability to resist chloride ion penetration, American Society for Testing and Materials, Philadelphia, Pennsylvania.
|
10 |
ASTM G 109. (2013), Standard Test method for determining the effects of chemical admixtures on the corrosion of embedded steel reinforcement in concrete exposed to chloride environments, American Society for Testing and Materials, Philadelphia, Pennsylvania.
|
11 |
ASTM C 856. (2014), Standard Practice for Petrographic Examination of Hardened Concrete, American Society for Testing and Materials, Philadelphia, Pennsylvania.
|
12 |
CSHRP. (1990), Effectiveness of epoxy-coated reinforcing steel, Canadian Strategic Highway Research Program, Final Report.
|
13 |
Haque, M.N., Al-Khaiat, H. and John, B. (2007), "A prelude to designing durable concerete structures in the Arabian Gulf", Build. Environ., 42(6), 2410-2416.
DOI
ScienceOn
|
14 |
Kayali, O. and Zhu, B. (2005), "Corrosion Performance of medium-strength and silica fume high-strength reinforced concrete in a chloride solution", Cement Concrete Compos., 27(1), 117-124.
DOI
ScienceOn
|
15 |
Shekarchi, M., Rafiee, A. and Layssi, H. (2009), "Long-term Chloride diffusion in silica fume concrete in harsh marine climates", Cement Concrete Compos., 31(10), 769-775.
DOI
ScienceOn
|
16 |
Whiting, D. (1981), Rapid determination of chloride permeability of concrete, Report No. FHWA/RD-81-119, Federal Highway Administration, Washington, D.C.
|