• Title/Summary/Keyword: Concrete Filled Tube(CFT)

Search Result 218, Processing Time 0.024 seconds

Evaluation of Fire Resistance of Unprotected Concrete-filled Rectangular Steel Tubular Columns under Axial Loading (재하가열시험에 의한 무내화피복 콘크리트충전 각형강관기둥의 내화성능평가)

  • Ahn, Jae Kwon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.323-334
    • /
    • 2014
  • In this paper, experimental program and associated numerical study were carried out to evaluate the fire resistance of unprotected concrete-filled rectangular steel tubular (CFT) columns subjected to the standard fire. The key testing parameters included the length effect, the load ratio, and the sectional dimensions of the CFT columns. Temperature distribution and axial deformation of the CFT column specimens were measured and analyzed. Rather early local buckling of steel tubes was observed in all the specimens. This caused subsequent load transfer from steel tube to concrete, and eventually triggered concrete crushing, or complete loss of the load bearing capacity of the column. This implies that the limit state of local buckling as well as overall flexural buckling should be incorporated in fire design procedure. As expected, the fire resistance time of specimen with higher load ratio consistently lessened. The prediction of fire resistance time of unprotected CFT columns based on the limiting steel temperature in current design codes or the formula proposed by previous studies is slightly conservative compared to the fire test results available. To establish the finite element analysis model that can be used to predict the thermal and structural behaviour of unprotected CFT columns in fire, the fully coupled thermal-stress analysis was also tried by using the commercial code ABAQUS. The numerical results showed a reasonable global correlation with the experimental results.

Experimental Study of the Fire Behavior of CFT Columns in Relation to the Sectional Shape & Size (단면형상 및 크기에 따른 콘크리트 충전강관(CFT) 기둥의 화재거동에 관한 실험적 연구)

  • Cho, Bum-Yean;Kim, Heung-Youl;Kwon, Ki-Seok;Yang, Seung-Cho
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • In this study, fire resistance tests were conducted to evaluate the fire resistance performance of unprotected and non-welded CFT columns in relation to the shape and size of cross-sections. Unprotected slot-type CFT columns which were ${\square}300$ and ${\square}500$ in dimensions resisted fire for 125 minutes and more than 180 minutes, respectively. Strain analysis showed that slot-type CFT columns were more ductile than welded CFT columns. The temperatures of central parts measured when welded CFT columns and slot-type CFT columns had lost fire resistance performance were higher in the former than the latter. Therefore, slot connection does not a great influence on the temperatures inside the concrete.

Water pressure Test and analysis for Welding Thickness Decision of New Cold-formed Type Concrete Filled Tubular Square Column (조립각형 CFT 기둥의 용접크기 결정을 위한 수압실험 및 해석)

  • Lee, Seong-Hui;Kim, Sun Hee;Kim, Young Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.515-526
    • /
    • 2009
  • There are three main production processes in the manufacture of concrete-filled square steel columns. The first process is known as the 'box-type process' or 'four-seam method,' wherein four beams are welded together at the seams. The second is the 'cold-forming process' or 'two-seam method,' wherein the seams of two channel beams are welded together. The third is the 'pressing process' or 'one-seam method,' wherein a circular column is pressed until it becomes a square column. In calculating the production cost for the making of a steel tube, it is very important to consider the welding process to be used and the desiredthickness of the steel tube, such as a square column that was developed under a new method, formed through the four-seam flare welding method at the center of the steel column width, following the L-shape formation. Certain tests were suggested in this study to evaluate the welding amount of concrete-filled square steel columns. With the parameters of the production method of a square steel column, the thickness of the steel square columns, and the welding amount, six specimens were produced. A structural test and finite-element analysis were conducted to assess the behavior of the steel column according to the water pressure inside the steel columns.

Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load (반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동)

  • Kang, Chang-Hoon;Moon, Tae-Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.387-395
    • /
    • 2000
  • The purpose of this research is to evaluate the capacity of strength and plastic deformation of those members, and provide experimental data on the seismic behavior of these members as a basis for developing guidelines for designing seismically resistant concrete-filled steel tubular columns. Eighteen cantilever-type specimens were tested under constant axial load and cyclically lateral load as models of bottom columns in high-rise building. The parameters studied in the test program included, are width-thickness ratio of steel tube, slenderness ratio (Lo/D) and axial force ratio. From the test results, the effects of parameters on the strength, the deformation capacity, energy absorption capacity are discussed. The specimen flexural capacity under combined axial and lateral loading was found to be almost accurately predicted by criteria AIJ and AISC-LRFD providing conservative results. Therefore KSSC for encased composite column can be applied to the concrete filled column if composite section and elastic modulus are modified according to AIJ and AISC-LRFD. Finally, the proposed flexural capacity considering confinement effects is a food agreement on the tests results.

  • PDF

Centrifuge Tests on Compression Performance of Octagonal Concrete Filled Tube Column to be applied to Top-Down Construction Method (역타공법에 적용되는 팔각 콘크리트충전 강관의 압축성능을 위한 원심모형실험)

  • Kim, Dong-Kwan;Lee, Seung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.9-16
    • /
    • 2017
  • To improve concrete-filled tube (CFT) columns, an octagonal concrete-filled tube (OCFT) column was developed. Because the OCFT column requires a small boring diameter, the OCFT column is suitable for Top-Down construction method. In this study, the compression performance of OCFT column to be used as Top-Down pile foundation was verified using centrifuge equipment. Under 12 g centrifugal acceleration, the bearing capacities of the pile foundations of OCFT and H-shaped sections were tested. When the pile foundations were embedded in soil of full depth, 45 % of the design strength, which was assumed to be the construction load, was supported by the OCFT and H-shaped sections in the elastic states. When the pile foundations were embedded in soil of half depth, the buckling of the pile foundations was not investigated. After the loading test, the rock at the bottom of pile foundation, which had a strength of 3.5 MPa, was not damaged due to 45 % of the design strength.

4th Industrial Revolution Construction and Machinery Covergence Technology base Rotational Modular Housing of CFT Central Axis Structure (4차산업혁명 건설 및 기계 융합기술기반 CFT 중심축 구조체의 회전형 모듈러주택)

  • Kim, Dae-Geon;Woo, Jong-Yeol;Woo, A-Jin;Jeon, ho gyeong;Hong, young ju;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.179-180
    • /
    • 2018
  • This study aims to provide a more comfortable environment for the external environment by designing a rotable dwelling that deviates from the conventional fixed residential concept. The round pillars, which are the center of the building, are constructed by placing the CFT (concrete Filled steel Tube) technique in place and assembling modular houses with columns. This study combines existing building techniques. Korea also needs to develop various related studies quickly.

  • PDF

Development of Seismic Strengthening Composite Method using Steel type CFT Frame (철골형 CFT 프레임을 활용한 내진보강 복합공법 개발)

  • Lee, Dong-Oun;Woo, Jong-Yeol;Park, Hyeon-Jeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.101-102
    • /
    • 2018
  • There is a risk that the damage caused by frequent earthquakes can lead to the risk of personal injury due to cracks in buildings and collapse of major structures. Although the seismic design of the new building is designed to be reinforced, the existing structure is not exposed to the risk of earthquake. Therefore, it is aimed to develop the steel frame type CFT composite method which can easily reinforce the CFT structural system with excellent seismic performance against the old non - seismic structure.

  • PDF

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Characteristics of Concrete Filled Circular Tubular Stub Columns based on Experiment and Data Analysis (실험 및 데이터 분석에 의한 CFCT 단주 특성)

  • Kang, Hyun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.161-168
    • /
    • 2001
  • The use of composite members to improve the compressive strength of steel structure is a common practice these days and its efficiency has already been proved by several researches and experiments. The result of concrete filled circular tubular(CFCT) stub column tests is introduced in this paper. The main parameter of this test is the ratio of diameter to thickness of circular hollow section. From the test results, the effect of concrete filled in steel tube on the ultimate strength, the deformation capacity and initial stiffness are discussed. The purpose of this paper is to investigate the effect of various parameters and evaluate the compressive strength of confined concrete. It would contribute to a better understanding of CFT structure, further laboratory experimentations are needed for better accurate estimation on its effect.

  • PDF

Structural Performance of High-Strength Concrete-Filled Steel Tube Steel Columns using Different Strength Steels (이종강종을 사용한 고강도 CFT 합성부재의 구조성능)

  • Choi, In Rak;Chung, Kyung Soo;Kim, Jin Ho;Hong, Geon Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.711-723
    • /
    • 2012
  • Structural tests were performed to investigate the structural performance of concrete-filled steel tube column using different strength steels in their flange and web with high-strength steel HSA800 and mild steel SM490, respectively. The test parameters included the strength of column flange and infill concrete, and effect of concrete infill. Connection between different grade steels were welded using the electrode appropriate for mild steel and verified its performance. To evaluate the behavior of test specimens, eccentric loading tests were performed and the results were compared with the prediction by current design codes. Axial load and moment carrying capacity of test specimens increased with the yield strength of compression flange and weld fracture occurred after the specimen shows full strength. The prediction result for axial load-bending moment relationship and effective flexural stiffness gave good agreement with the test result.