Browse > Article

Water pressure Test and analysis for Welding Thickness Decision of New Cold-formed Type Concrete Filled Tubular Square Column  

Lee, Seong-Hui (서울시립대학교 구조연구실)
Kim, Sun Hee (서울시립대학교 구조연구실)
Kim, Young Ho (세진특허법률사무소)
Choi, Sung Mo (서울시립대학교 건축학부)
Publication Information
Journal of Korean Society of Steel Construction / v.21, no.5, 2009 , pp. 515-526 More about this Journal
Abstract
There are three main production processes in the manufacture of concrete-filled square steel columns. The first process is known as the 'box-type process' or 'four-seam method,' wherein four beams are welded together at the seams. The second is the 'cold-forming process' or 'two-seam method,' wherein the seams of two channel beams are welded together. The third is the 'pressing process' or 'one-seam method,' wherein a circular column is pressed until it becomes a square column. In calculating the production cost for the making of a steel tube, it is very important to consider the welding process to be used and the desiredthickness of the steel tube, such as a square column that was developed under a new method, formed through the four-seam flare welding method at the center of the steel column width, following the L-shape formation. Certain tests were suggested in this study to evaluate the welding amount of concrete-filled square steel columns. With the parameters of the production method of a square steel column, the thickness of the steel square columns, and the welding amount, six specimens were produced. A structural test and finite-element analysis were conducted to assess the behavior of the steel column according to the water pressure inside the steel columns.
Keywords
concrete filled tubular column; welding capacity; welding detail; economic efficiency; workability;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 이성희, 이인호, 권순명, 이장홍, 최성모(2007), 신 냉간성형CFT 기둥의 용접크기 결정을 위한 수압실험 연구, 한국강구조학회 2007년도 학술발표대회 논문집, p.685-690
2 BS standard(1992), Eurocode 3 : Design of steel structures(part 1.1 General rules and rules for buildings)
3 B. Uy, S. Das(1999) Bracing of thin walled steel box columns during pumping of wet concrete in tall buildings, Thin-Walled Structures, vol. 33, no. 2, p.127-154   DOI   ScienceOn
4 이성희, 박제한, 윤여상, 백일현, 최성모(2007), 신 냉간성형 각형 CFT 장주기둥의 구조특성에 관한 실험적 연구, 한국강구조학회 2007년도 학술발표대회 논문집, p.672-677
5 대한건축학회(2005), 건축구조설계기준(KBC), 대한건축학회
6 이성희, 박제한, 염경수, 김진호, 최성모(2007), 신 냉간성형 각형 CFT 단주기둥의 구조특성에 관한 실험적 연구, 한국강구조학회 2007년도 학술발표대회 논문집, p.665-671
7 이성희(2008) 용접조립 각형CFT 기둥 및 접합부의 거동, 서울시립대학교 대학원
8 B. Uy, S. Das(1997) Wet concrete loading of thin-walled steel box columns during the construction of a tall building, Journal of Constructional Steel Research, vol. 42, no. 2, p.95-119   DOI   ScienceOn
9 Marshall, Peter William(1992), Design of welded tubular connections : basis and use of AWS code provisions, Amsterdam, Elsevier
10 이성희, 최영환, 염경수, 김진호, 최성모(2008), 용접조립 각형CFT 단주의 구조특성에 관한 실험적 연구, vol.20, n.5,p645-653