• Title/Summary/Keyword: Concrete Filled Steel Tube(CFT)

Search Result 198, Processing Time 0.022 seconds

A Study on the Flexural Behavior of Concrete Filled Steel Tube Girder in Parametrically Varied Filling and Composition (충전 및 합성조건 변화에 따른 콘크리트 충전강관 거더의 휨거동에 관한 연구)

  • Chin, Won Jong;Kang, Jae Yoon;Choi, Eun Suk;Lee, Jung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2A
    • /
    • pp.109-118
    • /
    • 2009
  • A new bridge system described in this paper uses concrete-filled steel tube (CFT) girders as a replacement for conventional girders. Experimental investigations were carried out to comprehend the flexural behavior of CFT girder. Specimens were manufactured considering several parameters such as the strength of filling material, the eventual presence and number of inner shear connectors to evaluate the bending bearing capacity of CFT girder. The experimental investigation consisted of designing and constructing a test specimen and loading it to collapse in bending to check the applicability of the system. Test results showed that concrete filled steel tube girders have good ductility and maintain their strength up to the end of the loading. The stiffening effect of the ㄱ-shaped perfobond rib is determined to contribute relatively to the increase of the bending bearing capacity.

Ductility Capacity for Concrete Filled Steel Circular Tubes Reinforced by Carbon Fiber Sheets(CFSs) (탄소섬유쉬트로 보강된 콘크리트충전 원형강관기둥의 연성능력)

  • Park, Jai-Woo;Hong, Young-Kyun;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.2
    • /
    • pp.185-195
    • /
    • 2010
  • This paper presents the experiment results for a CFT column confined by carbon fiber sheets(CFSs) under an axial load. Nine specimens were constructed and axial compression tests were conducted. The main experiment parameters were diameter-thickness ratio(D/t), reinforcing CFSa, and the attachment of a cushion gap between surface of steel tube and CFSs. The load-displacement curves of the specimens were obtained from the compression tests. Finally, it was concluded that the CFT column with a gap had grater ductility capacity improvement that the CFT column confined by CFSs.

Development of Non-linear Finite Element Modeling Technique for Circular Concrete-filled Tube (CFT) (원형 콘크리트 충전 강관 (CFT)의 비선형 유한 요소 해석 기법 개발)

  • Moon, Jiho;Ko, Heejung;Lee, Hak-Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.139-148
    • /
    • 2012
  • Circular concrete-filled tubes (CFTs) are composite members, which consists of a steel tube and concrete infill. CFTs have been used as building columns and bridge piers due to several advantages such as their strength-to-size efficiency and facilitation of rapid construction. Extensive experimental studies about CFT have been conducted for past decades. However experimental results alone are not sufficient to support the engineering of these components. Complementary advanced numerical models are needed to simulate the behavior of CFT to extend the experimental research and develop predictive tools required for design and evaluation of structural systems. In this study, a finite element modeling technique for CFT was developed. The confinement effects, and behavior of CFT subjected various types of loading predicted by the proposed finite element model for CFT were verified by comparing with test results.

An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection (내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구)

  • Kim, Hae-Soo;Lee, Chy-Hyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.

An Experimental Study on the Property of High Performance Concrete for Concrete Filled Tube with Addition Content of Steel Fiber (강섬유 첨가량에 따른 콘크리트 충전강관용 고성능 콘크리트 특성에 관한 실험적 연구)

  • Seo, Il;Hong, Seok-Beom;Yoo, Jo-Hyeong;Park, Hee-Gon;Kim, Woo-Jae;Lee, Jae-Sam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.213-214
    • /
    • 2012
  • This paper presents basic study to develop high performance concrete for concrete filled tube with addition content of steel fiber. In this study, all mixtures was added to nylon fiber (1.5 kg/㎥) and steel fiber was mixed by 0, 20 and 40 kg/㎥ respectively. To evaluate the property of high performance concrete was used to various test methods which were slump flow, air content, U-box test, O-lot test and L-flow(to 300 mm, 500 mm). Also, compressive strength test was measured by ages.

  • PDF

A Study on the Load Carrying Capacity and Deformation Capacity of the Internal Anchors Welded Cold Formed Concrete Filled Columns (내부앵커형 콘크리트 충전 기둥의 내력 및 변형능력에 관한 연구)

  • Kim, Sun Hee;Yom, Kong Soo;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.347-357
    • /
    • 2013
  • Recently, In recognition of outstanding structural performance the use of Concrete Filled steel Tube(CFT) columns has been increased. Research is ongoing that effective use of cross-sectional because steel strength development and rising prices. In this Lab, suggests new shape by Thin steel plates bent to be L-channel welded to form square steel tube to maximize efficiency of the cross section. In addition, since the rib placed at the center of the tube width acts as an anchor; higher load capacity of buckling is acceptable. we have developed New shape welded built-up square tube for broader usability which were bent to be L-shaped and thin Plate each unit member were welded. In order to apply the new shape built-up square columns, we predicted structure behavior, stress distribution with parameter Width thickness ratio. The experimental results presented in standards and even exceed the b/t of the rib anchors installed in the role due to exert enough strength and deformation to improve performance was favorable.

Ultimate Resisting Capacity of Axially Loaded Circular Concrete-Filled Steel Tube Columns (축력이 재하된 원형 콘크리트 충전강관 기둥의 최대 저항능력)

  • Kwak, Hyo-Gyoung;Kwak, Ji-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.423-433
    • /
    • 2012
  • The axial load on the concrete-filled steel tube (CFT) column produces confinement stress, which enhances strength of the core concrete. The amount of strength increase in concrete depends on the magnitude of produced confinement stress. From nonlinear analyses, the ultimate resisting capacity of the CFT columns subjected to axial loads was calculated. Nonlinear material properties such as Poisson's ratio and stress-strain relation were considered in the suggested model, and the maximum confining stress was obtained by multi axial yield criteria of the steel tube. This proposed model was verified by comparing the analytical results with experimental results. Then, regression analyses were conducted to predict the maximum confining stress according to D/t ratio and material properties without rigorous structural analysis. To ensure the validity of the suggested regression formula, various empirical formulas and Eurocode4 design code were compared.

Evaluation of ductility and response modification factor in moment-resisting steel frames with CFT columns

  • Hashemi, Seyed Sh.;Sadeghi, Kabir;Vaghefi, Mohammad;Shayan, Kaveh
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.643-652
    • /
    • 2017
  • One of the methods to strengthen the structures against the seismic lateral loading is the employment of the composite columns. A concrete-filled tube (CFT) has the cumulative advantages of steel and concrete. Concrete-filled steel tube columns have been widely used in the moment-resisting frame (MRF) structures, located in both non-seismic zones and high-risk seismic zones. In this paper, the results of studies on two important seismic parameters of ductility and the response modification factor (RMF) of the MRFs with CFT columns are submitted. While the studies are carried out, the effects of span length-story height ratio, the strength of materials and seismic behavior of MRFs are considered. In this regard, the ductility, RMF and the strength of 36 models of the steel MRFs with CFTs are analyzed. The fiber plastic hinges numerical simulation and pushover analysis method are used in the calculations. Based on the obtained results, the RMFs suitable for the 5-, 10- and 15- story frames are proposed.

Analysis of the Axial Force-Bending Moment Interaction for a CFT Column Considering the Confining Effect and the Material Nonlinearity of Concrete (콘크리트의 구속효과와 재료비선형을 고려한 내부 구속 CFT 기둥의 축력-모멘트 상호작용 분석)

  • Han Taek-Hee;Youm Eung-Jun;Yoon Ki-Yong;Lee Chang-Soo;Kang Jin-Ook;Kang Young-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.141-148
    • /
    • 2006
  • Concrete in a CFT(Concrete Filled Tube) column has enhanced strength and ductility because it is triaxially confined by a steel tube. But CFT columns are designed based on linear analyses by stress block method without the confining effect or the nonlinearity of the concrete. These make the significantly difference between the analysis results and the experimental results. Thus in this study, a nonlinear CFT column model was developed considering the confining effect on the concrete in a CFT column. This developed model was verified by experimental results from other researchers and compared with the results of various specifications. With the developed model, parametric studies were performed and the developed column model showed reasonable and accurate results.

  • PDF

Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load (일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구)

  • Chung, Kyung Soo;Choi, In Rak;Kim, Do Hwan;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.71-80
    • /
    • 2013
  • Fire-resistant (FR) test data for a square concrete-filled steel tube (CFT) columns consisting of high-strength steel (fy>650MPa) and high strength concrete (fck>100MPa) under axial loads are insufficient. The FR behavior of square high-strength CFT members was investigated experimentally for two specimens having ${\Box}-400{\times}400{\times}15{\times}3,000mm$ with two axial load cases (5,000kN and 2,500kN). The results show that the FR performance of the high-strength CFT was rapidly decreased at earlier time (much earlier at high axial load) than expected due to high strength concrete spalling and cracks. In addition, a fiber element analysis (FEA) model was proposed and used to simulate the fiber behaviour of the columns. For steel and concrete, the mechanical and thermal properties recommended in EN 1994-1-2 are adopted. Test results were compared to those of numerical analyses considering a combination of temperature and axial compression. The numerical model can reasonably predict the time-axial deformation relationship.