• Title/Summary/Keyword: Concentration curve

Search Result 1,293, Processing Time 0.026 seconds

A Study on the Manufacturing and Physical Properties of Conducting Rubber(I) - Magnetite System Conducting Rubber - (도전성(導電性)고무의 제조(製造) 및 물성(物性)에 관(關)한 연구(硏究)(I) -Magnetite 혼합계(混合系) 도전성(導電性)고무-)

  • Lee, Young-Man;Yun, Ju-Ho;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.30 no.1
    • /
    • pp.9-19
    • /
    • 1995
  • To make filler loaded conducting rubber which has the excellent electronical and physical properties, CR and NBR were mixed with magnetite$(Fe_3O_4)$. From the result of the study, vulcanization characteristics shows the upgrading curve as increase in filler concentration and CR has more torque than NBR. When elongation be higher, modulus comes to decreases. Tear strength gradually decrease after showing of the maximum point when is in the 100phr in all. Resilience is not good to cause the increase in filler concentration. In the electrical properties, conductivity becomes smaller when filler concentration is increased. The increase of voltage makes an conductivity grown, but the changed rate is weak. The influence of temperature hardly changes on increasing temperature. The morphology and the distribution for a conductivity filler through SEM were better, the more filler concentration increase, the shorter the particle interval is.

  • PDF

Comparison of Some Antioxidative Activities of Feeding Honey from the Mixture of Extract of Rubus Coreanus Miquel and Sugar with Three Types of Honeys on the Market (복분자 추출액 급이 사양꿀과 일부 시판꿀의 항산화활성 비교)

  • Oh, Hae-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.4
    • /
    • pp.641-649
    • /
    • 2010
  • To make sure of the usefulness of extract of Rubus coreanus Miquel for producing functional feeding honey, we compared some antioxidative indicators of feeding honey using extract of Rubus coreanus Miquel with acacia honey, SueBee Clover honey(USA), feeding honey on the market. The water content of four honeys were 16.6~26.5%, pH were 3.18~3.70, and titratable acidity ranged 0.018~0.022%. The phenolic compound contents of SueBee Clover honey and feeding honey using extract of Rubus coreanus Miquel were 8.3 mg/100 g and 7.3 mg/100 g, respectively, and were significaltly higher thgheacacia honey and feeding honey on the market. The flavonoid contents per 100 g of honey ranged from 2.3 mg(acacia honey) to 15.0 mg(SueBee Clover honey). DPPH anion scavenging activity of four honeys were not high. 0.5~2.0 g/ml of feeding honey using extract of Rubus coreanus Miquel was 16~36% and showed a concentration-reliant figure. At the concentration of 0.25~0.75 mg/ml, the reducing power of four honeys increased concentration-dependently, and the power of 0.25 mg/ml of feeding honey using extract of Rubus coreanus Miquel was corresponding to thgt of $150{\mu}g$/ml of a vitamin C solution. ABTS radical scavenging activity of feeding honey using extract of Rubus coreanus Miquel was 43.3~68.4%; the highest activity amongst all samples. When plotting the dose-response curve, ABTS radical scavenging activity also increased as their concentration increased from 62.5 mg/ml to 500 mg/ml. The heat treatment reduced the phenolic compound contents of acacia honey and feeding honey using extract of Rubus coreanus DPPH anion scavenging activity of feeding honey on the market and feeding honey using extract of Rubus coreanus Miquel did not changed significaltly after heating for 20 min, and the three honey except SueBee Clover honey maintained the reducing power with the same treatment.

Improvement in Thin-layer Chromatography in a Quantitative Assay of Glycerol in Biodiesel (개선된 thin-layer chromatography를 이용한 바이오디젤 중의 글리세롤 정량분석)

  • Lee, Sang-Eun;Choi, Woo-Seok;Kang, Do-Hyung;Lee, Hyeon-Yong;Jung, Kyung-Hwan
    • Journal of Life Science
    • /
    • v.23 no.4
    • /
    • pp.537-541
    • /
    • 2013
  • We analyzed glycerol using thin-layer chromatography (TLC) and compared the separation resolution of some mobile phases. When acetonitrile:distilled water (85:15 v/v) was used as a mobile phase, the band of glycerol on the TLC was more distinctly and rapidly separated. Using TLC analysis, we prepared a calibration curve for the glycerol concentration vs. the area of the glycerol band in which the glycerol concentration of the x-axis was converted into a log-scale ranging from 3.0 to 0.0625 (%, w/v). Based on this calibration curve, the residual glycerol concentration (0.2 [%, w/v]) in biodiesel was determined successfully using TLC analysis. When the results of the TLC analysis were compared with those of a chemical and enzymatic assay, the results were fairly similar. We conclude that TLC without additional analytical instruments can be used as an alternative method for the quantitative analysis of the concentration of glycerol in biodiesel.

The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer (유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구)

  • Joo, Sung-Kyun;Kim, Joon;cheong, Nam-Yong;Lim, Kyu-Chual;Choi, Young-Hwan;Kim, Sang-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 $\sim$ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.

Effects of feed intake and water hardness on fluralaner pharmacokinetics in layer chickens

  • Sari, Ataman Bilge;Gunes, Yigit;Anlas, Ceren;Alkan, Fulya Ustun;Guncum, Enes;Ustuner, Oya;Bakirel, Tulay
    • Journal of Veterinary Science
    • /
    • v.23 no.5
    • /
    • pp.64.1-64.9
    • /
    • 2022
  • Background: Fluralaner is a novel drug belonging to the isoxazoline class that acts on external parasites of domestic animals. It is used systemically via drinking water, especially against red poultry mite in layer chickens. Fluralaner is frequently used in layers infected with D. gallinae. However, no study to date has investigated the effects of feed intake and water hardness. Objectives: This study aimed to investigate the effects of variable water hardness and feed intake on the pharmacokinetic profile of fluralaner. Methods: Layer chickens were divided into four groups (n = 8): fed + purified water (Group 1), feed restricted + purified water (Group 2), feed restricted + hard water (Group 3), and feed restricted + soft water (Group 4). After administering a single dose of the drug with drinking water, the blood samples were collected for 21 days. Fluralaner concentrations in plasma samples were determined by liquid chromatography/tandem mass spectrometry. The maximum plasma concentration (Cmax), time to reach maximum plasma concentration (tmax), area under the concentration-time curve values (AUC0-21d), half-life (t1/2), and other pharmacokinetic parameters were calculated. Results: Although the highest maximum plasma concentration (Cmax) was determined in Group 1 (fed + purified water), no statistically significant difference was found in the Cmax, tmax, t1/2, MRT0-inf_obs, Vz/Fobs, and Cl/F_obs parameters between the experimental groups. Conclusions: It was concluded that the feed intake or water hardness did not change the pharmacokinetic profile of fluralaner in layer chickens. Therefore, fluralaner could be used before or after feeding with the varying water hardness in poultry industry.

Measurement of Langmuir Adsorption Equilibrium by Elution-curve Method and Frontal Analysis (용출곡선법과 Frontal Analysis를 이용한 Langmuir 흡착평형식의 측정)

  • Choi, Yong Seok;Lee, Chong Ho;Row, Kyung Ho
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.672-676
    • /
    • 1999
  • Adsorption isotherm is the most fundamental information in adsorption separation-process. Directly from the elution profile of a peak, the elution-curve method and frontal analysis(FA) were utilized to measure the adsorption isotherm in this work. Using RP-HPLC, sample and the buffer added in mobile phase were 5'-GMP and sodium phosphate, respectively. In this experimental condition, the retention time was decreased with increase in the injected mass of sample. And the front part of a peak was very stiff, so Langmuir adsorption isotherm might be applied. By the elution-curve method, the parameters used in the isotherm were obtained by optimization method, while by the FA, the concentrations of stationary phase were measured from the elution curve and the isotherm was determined by regression analysis. Compared to FA, the consumption of sample was less, and only one or two injections were needed by the elution-curve method. Finally, the effect of concentration of sodium phosphate in mobile phase on the parameters of the isotherm was investigated.

  • PDF

Pedagogical Implications for Teaching and Learning Normal Distribution Curves with CAS Calculator in High School Mathematics (CAS 계산기를 활용한 고등학교 정규분포곡선의 교수-학습을 위한 시사점 탐구)

  • Cho, Cheong-Soo
    • Communications of Mathematical Education
    • /
    • v.24 no.1
    • /
    • pp.177-193
    • /
    • 2010
  • The purpose of this study is to explore normal distribution in probability distributions of the area of statistics in high school mathematics. To do this these contents such as approximation of normal distribution from binomial distribution, investigation of normal distribution curve and the area under its curve through the method of Monte Carlo, linear transformations of normal distribution curve, and various types of normal distribution curves are explored with CAS calculator. It will not be ablt to be attained for the objectives suggested the area of probability distribution in a paper-and-pencil classroom environment from the perspectives of tools of CAS calculator such as trivialization, experimentation, visualization, and concentration. Thus, this study is to explore various properties of normal distribution curve with CAS calculator and derive from pedagogical implications of teaching and learning normal distribution curve.

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

Analysis of Current-voltage Characteristic Curve for the Solar Cell using MicroTec Tool (MicroTec을 이용한 태양전지 전류-전압 특성곡선 분석)

  • Jung, Hak-Kee;Han, Ji-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1045-1050
    • /
    • 2009
  • The current-voltage characteristics of solar cell has been analyzed using MicroTec in this paper. The current-voltage characteristics represents a efficiency of solar cell. The part of metal contact is doped highly, but active region is doped lowly. We have investigated the current-voltage characteristics according to variation of doping concentration from $10^{14}cm^{-3}$ to $10^{17}cm^{-3}$. We has also determined the doping concentration to obtain the maximum efficiency of solar cell, and analyzed this current-voltage characteristics.

The Effect of Electrolytes on Polshing Behavior in Cu ECMP (Cu ECMP 공정에서 전해액이 연마거동에 미치는 영향)

  • Kwon, Tae-Young;Kim, In-Kwon;Kim, Tae-Gon;Cho, Byung-Gwun;Park, Jin-Goo
    • Korean Journal of Materials Research
    • /
    • v.18 no.6
    • /
    • pp.334-338
    • /
    • 2008
  • The purpose of this study is to characterize various electrolytes on electrochemical mechanical planarization (ECMP). The ECMP system was modified from conventional CMP system to measure the potentiodynamic curve and removal rate of Cu. The potentiodynamic curves were measured in static and dynamic states in investigated electrolytes using a potentiostat for the evaluation of the polishing behavior on ECMP. KOH (alkaline) and $NaNO_3$ (salt) were selected as electrolytes which have high conductivity. In static and dynamic states, the corrosion potential decreased and the corrosion current increased as a function of the electrolyte concentration. But, the electrochemical reaction was prevented by mechanical polishing effect in the dynamic state. The static etch and removal rate were measured as functions of concentration and applied voltage. When $NaNO_3$ was used, the dissolution was much faster than that of KOH. It was concluded that the removal rate was strongly depended on electrochemical dissolution. The removal rate increased up to 350 nm/min in $NaNO_3$ based electrolyte.