• Title/Summary/Keyword: Concentration and tracking

Search Result 142, Processing Time 0.024 seconds

Development of Solar Concentrator Cooling System (태양광 시스템의 냉각장치 개발)

  • Lee, HeeJoon;Cha, Gueesoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4463-4468
    • /
    • 2014
  • To increase the efficiency of a solar module, the development of solar concentrator using a lens or reflection plate is being proceeded actively and the concentrator pursues the a concentration using a lens or an optical device of a concentration rate and designing as a solar tracking system. On the other hand, as the energy density being dissipated as a heat according to the concentration rate increases, the cares should be taken to cool the solar concentrator to prevent the lowering of efficiency of solar cell by the increasing temperature of the solar cell. This study, researched and developed an economical concentrator module system using a low priced reflection optical device. A concentrator was used as a general module to increase the generation efficiency of the solar module and heat generated was emitted by the concentration through the cooling system. To increase the efficiency of the solar concentrator, the cooling system was designed and manufactured. The features of the micro cooling system (MCS) are a natural circulation method by the capillary force, which does not require external power. By using the potential heat in the case of changing the fluid, it is available to realize high performance cooling. The 117W solar modules installed on the reflective plate and the cooling device in the cooling module and the module unit was not compared. The cooling device was installed in the module resulted in a 28% increase in power output.

The Effect of PPL on the User's Visual Attention Using Eye-tracking (아이트래킹을 활용한 PPL이 수용자의 시각적 주의에 미치는 영향)

  • Wang, Wan-Nan;Park, Min-Hee;Hwang, Mi-Kyung;Kwon, Mahn-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.445-452
    • /
    • 2021
  • This paper is an experimental study using eye-tracking on the visual attention of TV entertainment programs with PPL products being shoveled by the acceptor. As a result of analysis, first, there was no difference in the exposure time of the PPL product, which is deemed to have little effect on the subject's attention. Second, there was no difference in the PPL product's prominence, and we could see that the focus was on subtitles or the faces of the cast. Third, the concentration of attention on PPL products was higher when there were more famous cast members than there were when there were low-profile cast members, and the appearance of famous cast members was judged to be very effective in order to focus more attention on PPL products. In conclusion, when exposing PPL products in entertainment programs, it is believed that the more popular the cast members appear on entertainment shows, such as famous broadcasters, celebrities, and stars, the more effective the PPL products are, rather than the exposure time and prominence of PPL products, the more effective the companies will be in advertising the popular and likable celebrities.

Visible Light Communication Based Wide Range Indoor Fine Particulate Matter Monitoring System (가시광통신 기반 광역 실내 초미세먼지 모니터링 시스템)

  • Shakil, Sejan Mohammad Abrar;An, Jinyoung;Han, Daehyun;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Fine particulate matter known as PM 2.5 refers to the atmospheric particulate matter that has a diameter less than 2.5 micrometer identified as dangerous element for human health and its concentration can provide us a clear picture about air dust concentration. Humans stay indoor almost 90% of their life time and also there is no official indoor dust concentration data, so our study is focused on measuring the indoor air quality. Indoor dust data monitoring is very important in hospital environments beside that other places can also be considered for monitoring like classrooms, cements factories, computer server rooms, petrochemical storage etc. In this paper, visible light communication system is proposed by Manchester encoding technique for electromagnetic interference (EMI)-free indoor dust monitoring. Important indoor environment information like dust concentration is transferred by visible light channel in wide range. An average voltage-tracking technique is utilized for robust light detection to eliminate ambient light and low-frequency noise. The incoming light is recognized by a photo diode and are simultaneously processed by a receiver micro-controller. We can monitor indoor air quality in real-time and can take necessary action according to the result.

Development of a Page Turner Application based on Eye Tracking Algorithm for the Performing Artists (연주자를 위한 시선 추적 기반 페이지 터너 애플리케이션 개발)

  • Kim, Tae-Yu;Kim, Seokhoon
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.829-836
    • /
    • 2018
  • Sheet music is one of the inevitable elements for successful melody interpretation, playing or rendering, and performance, most of performing artists usually utilize a paper sheet music in the cases. However, the paper sheet music can be a one of the reason to degrade the concentration of audiences and artists or entire performing flows. In addition, it might be a weakness to use a paper sheet music in an outside performing place. We propose an electronic sheet music page tuner application, which can overcome these problems, based on a Tablet PC. The proposed page tuner application, which uses the OpenCV to adapt an eye tracking and behavior recognition, can provide an automatical page pass function to the performing artists. We will expect that the proposed application can highly decrease the weakness of paper sheet music.

A Study on the set-up of Time Range for Typology of Space Observation Characters (공간주시특성의 유형화를 위한 시간범위설정에 관한 연구)

  • Kim, Jong-Ha;Jung, Jae-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.87-95
    • /
    • 2012
  • This study is for the analysis to which element of space the users observing the lobby at a public space pay more attention for their visual perception. It is focused on the typology process of observation characters. The subjects, in the observation process, came to be interested in the circumstantial clues for space perception and the detailed characters drawing their interest. I could analyze the observation characters of the subjects observing the space by the comprehension and typology of their observation characters. First, from the viewpoint of successive 9 times of observations, each subject observed for 0.32 second to get the visual perception in the applied space, but spent another 0.39 second for the exploration of another observation object or the space roaming. The observation character of the subjects at the lobby of the public space selected for this experiment was that they spent more time on space exploration than on concentration on a point in the space. Second, I analyzed the typology process through the time range. Since the subjects' frequency varied depending on the way to set up the time range, the necessity was proposed that the time range for the analysis of observation characters should be set up more objectively. Third, in case of analyzing the observation characters by 10-second-unit time range, the concentration in the beginning and the middle was 25%, and that in the beginning and the final 41.7%, which showed that 75% of the subjects concentrated in the beginning of the observation time when the concentration in the beginning is added to it. Fourth, the type 3 categorized as "concentration in the beginning and the middle" is the group 47.1 percent of the subjects belong to, and each subject concentrated 1.1 times in the beginning and 2.1 times in the final, which showed that the concentration in the final was 1.75 times as high as that in the beginning.

  • PDF

A Study on Observation Characteristics by Sex shown in the process of Visual Appreciation of Space (공간의 시각적 이해과정에 나타난 성별 주시특성에 관한 연구)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.152-161
    • /
    • 2013
  • This study is about the visual appreciation by sex with the analysis of time range of observing data which was got through observation experiment with the space of lobby in hospitals. The observation data of the subjects who observed the space include the frequency and time, through which the process of visual appreciation could be evaluated with the definition of the frequency and the time of observation. First, the fact that men had higher frequency of observation than women means the former had more movement than the latter, and another fact of their fewer times can be understood as the time of their staying was shorter. That is, even though the men had more movements of sight, they showed the feature of staying shorter. Second, the rate high and low of observation frequency and times made it possible for observation characteristics to be defined as 'intensive search' 'active search' 'fixed concentration' and 'search wandering.' The definition of understanding this process of visual appreciation can be available for a frame of effective analysis of observation characteristics according to the passage of time. Third, the intense search is the case of 'high frequency' having the feature of high visual appreciation owing to the active visual actions for acquiring information. Men were found to have more intense search which decreased gradually as time passed, while women showed the feature of many times of intense search. Fourth, it was found that with many observation data in a certain range of time the subjects had fixed concentration, where women were found to have repetitive fixed concentration along with the change of observation time while men were seen to have more observation tendency for fixed concentration. Fifth, at the cross tabulation of frequency and times, men had the feature of dispersed visual appreciation while women had more distinction between fixation and movement, which revealed that there is surely the difference between men and women in the process of visual appreciation.

Quantitative Analysis of Single Bacterial Chemotaxis Using a Hydrodynamic Focusing Channel (유체역학적 집속 효과를 이용한 단일 박테리아 주화성의 정량적 분석)

  • Jeon, Ho-Jeong;Lee, Yong-Ku;Jin, Song-Wan;Koo, Sang-Mo;Lee, Chang-Soo;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.3 s.258
    • /
    • pp.209-216
    • /
    • 2007
  • Bacterial chemotaxis is essential to the study of structure and function of bacteria. Although many studies have accumulated the knowledge about chemotaxis in the past, the motion of a single bacterium has not been studied much yet. In this study, we have developed a device microfabricated by soft lithography and consisting of microfluidic channels. The microfluidic assay generates a concentration gradient of chemoattractant linearly in the main channel by only diffusion of the chemicals. Bacteria are injected into the main channel in a single row by hydrodynamic focusing technique. We measured the velocity of bacteria in response to a given concentration gradient of chemoattractant using the microfludic assay, optical systems with CCD camera and simple PTV (Particle Tracking Velocimetry) algorithm. The advantage of this assay and experiment is to measure the velocity of a single bacterium and to quantify the degree of chemotaxis by statistically analyzing the velocity at the same time. Specifically, we measured and analyzed the motility of Escherichia coli strain RP437 in response to various concentration gradients of L-aspartate statistically and quantitatively by using this microfluidic assay. We obtained the probability density of the velocity while RP437 cells are swimming and tumbling in the presence of the linear concentration gradient of L-aspartate, and quantified the degree of chemotaxis by analyzing the probability density.

Simultaneous measurement of velocity and temperature fields in micro-scale flow and its application to electrokinetic flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2585-2590
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIF) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIF are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

  • PDF

Simultaneous Measurement of Velocity and Temperature Fields in Micro-Scale Flow and Its Application to Electrokinetic Flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.644-652
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIE) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIE are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

Analysis and solution to the phase concentration and DC-like component of correlation result in Daejeon correlator (대전 상관기의 상관 결과에 나타난 유사 DC 성분과 위상 집중 현상에 대한 원인 분석과 해결 방법)

  • Roh, Duk-Gyoo;Oh, Se-Jin;Yeom, Jae-Hwan;Oh, Chung-Sik;Jung, Jin-Seung;Chung, Dong-Kyu;Yun, Young-Joo;Oyama, Tomoaki;Ozeki, Kensuke;Onuki, Hirofumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.3
    • /
    • pp.191-204
    • /
    • 2013
  • In this paper, we investigated the correlation outputs of Daejeon correlator at the viewpoints of the buffer memory setting related to the fine delay tracking and the under/overflow issue in FFT modules, in order to eliminate DC-like component and phase concentration to 0 degree. As the ring buffer memory is being used for the fine delay tracking, the DC-like component in correlation outputs is generated by improper setting of data read/write address, and then that address setting method is modified to exclude a polluted FFT segment in correlation processing when crossing the port/stream boundary. The phase concentration to 0 degree at beginning of bandpass is caused by inadequate scaling factors, which may be the origins of under/overflow occurred at internal computation of FFT stage. With the revised method of the ring buffer memory setting and the scaling factors in FFT, we could obtain higher signal-to-noise ratio and flux density, compared to the previous method, through the correlation processing of true observational data.