• 제목/요약/키워드: Concentration Load

검색결과 1,033건 처리시간 0.025초

Effect of Dosage Level of Carcinogen and Clonorchis sinensis Infestation on Cholangiocellular Carcinoma Induction in Hamsters

  • Yoon, Byung-Il;Joo, Kyung-Whan;Lee, Joon-Sang;Lee, Jae-Hyun;Kim, Dae-Yong
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.79-82
    • /
    • 2001
  • The infection of liver flukes, Clonorchis sinensis (CS) and Opisthorchis viverrini (OV), has been known as a risk factor to induce cholangiocellular carcinoma (CCC) in human living in the endemic area, providing promoting effect on the liver initiated by chemical carcinogens. The present study evaluated the relationship between the dosage level of dimethylnitrosamine (DMN) and the infection load of CS in the neoplastic development by histopathological examination of the treated hamsters. To evaluate the effects of DMN, different doses of DMN ranging from 0 to 25 ppm were administered to hamsters with 20 CS metacercariea. For the risk assessment of the infection load, 0, 5, 15, 50 CS metacercariae were respectively infected with 12 ppm DMN. The mortality was closely related to the infection load rather than the concentration of DMN. The infection of CS clearly promoted the induction of CCC even at dose level of 6 ppm DMN. Only five metacercariae were enough to promote CCC induction at the concentration of 12 ppm DMN.

  • PDF

구조응력기반 마스터 피로 선도를 이용한 하중 비전달형 십자 필렛 용접조인트의 피로예측 (Fatigue Life Prediction of Non-Load-Carrying Cruciform Welded Joint using Master S-N Curve based on Structural Stress Approach)

  • 곽시영
    • Journal of Welding and Joining
    • /
    • 제33권6호
    • /
    • pp.49-54
    • /
    • 2015
  • Welding process is of importance to assemble products or structures, but also the process is structural weakness due to stress concentration in welding joint. The fatigue design of welded joint requires time & labor consuming fatigue test because the fatigue life is various according to the depth of joint, joint type and load type etc. In fatigue design codes, they guide to classify welding joints with their shape( BS7608, IIW Documents) and provide fatigue assessment information. In terms of numerical method for fatigue analysis, it is also difficult to decide the stress peak in joint because of mesh sensitivity which means that stress value is varies with element type or size on stress concentration zone. Hot-spot method is used generally, but Battelle of United States proposed Master S-N Curve based on structural stresses converted by mechanical equilibrium theory. In this research, we extracted master S-N curve from Battelle's fatigue test DB including test data of various welding joints to apply on Non-Load-Carrying cruciform Joint. Comparing fatigue results between the case of using normal stress and case of structural stress cor the cruciform Joint, The suggested Battelle method showed successive results.

삽교호수계의 수질총량관리제 시행방안 연구 (A Study on the Implementation Method of Total Water Quality Load Management in Sapkyo Lake Watershed)

  • 이상진;오혜정;이은형;정종관
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.807-814
    • /
    • 2006
  • Sapkyo Lake Watershed occupies about 19.3% of total area of Chungnam Province, and it is necessary to make a plan of counter-measure for the maintenance of public waterbody sound as well as to ensure water resources due to urbanization and industrialization in this area so densely populated and excessively developed. Conventionally water quality management has been enforced by concentration-based system which is not considered the carrying capacity of receptors, hence there are no proper measures for the prevention of an excessive pollutant load over a waterbody. So even though emission sources abide by the conventional permission regulation, then the quantity of wastewater is increased continuously and encountered water shortage to use finally. Therefore this research focused on the review of introduction of total water quality management system in Sapkyo Lake watershed to maintain public waterbody sound and to ensure water resources. By doing this research in introduction of the system in advance, it can contribute to establish the methodology on systematic water quality management. Also the application of this system in Sapkyo Lake watershed can promote the sustainable development of the area by harmonizing the environment and regional economy ultimately.

연안 하구역 내의 비점오염부하량 산정을 위한 수학모델의 적용 (A Mathematical Framework for Estimating Non-point Waste Load at Enclosed Beaches)

  • 안종호
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.111-115
    • /
    • 2010
  • Beaches in estuaries, bays, and harbors are frequently contaminated with indicators of human pathogens such as fecal indicator bacteria. Tracking down the sources of contamination at these enclosed beaches is complicated by the many point and non-point sources that could potentially degrade water quality along the shore. A mathematical framework was developed to test quantitative relationships between fecal indicator bacteria concentration in ankle depth water at enclosed beaches, the loading rate of fecal indicator bacteria from non-point sources located along the shore, physical characteristics of the beach that affect the transport of fecal indicator bacteria across the beach boundary layer, and a background concentration of fecal indicator bacteria attributable to point sources of fecal pollution that impact water quality over a large region of the embayment. Field measurements of fecal indicator bacteria concentrations and water turbulence at an enclosed beach were generally consistent with predictions and assumptions of the mathematical model, and demonstrated its utility for assessing waste load of non-point sources, such as runoff, bather shedding, bird droppings, and tidal washing of contaminated sediments.

Metal Deposit Distribution in Barrel Plating of Partially Conductive Load

  • 이완구
    • 기술사
    • /
    • 제16권3호
    • /
    • pp.68-73
    • /
    • 1983
  • IC전자부품 중 DIP계 종류를 바렐을 사용하여 주석도금 할 때에 그 전착현상을 조사하여 부분전류의 동태를 설명할 수 있는 변화인자를 알아보려 하였다. DIP와 같은 모양인 IC부품은 부분전도체로 구분되어지며 그 전착상태를 one-dimensional model로 분석하였을때, 가입전류밀도, 바렐의 회전속도, 용액중 금속이온 농도와 깊은 관계가 있음을 보인다. 다공질과 같은 것으로 간주한 one-dimensional model로서 의 이론식은 J=$\delta$'/$\beta$-{-c$^3$/${\gamma}$-exp-(1-$\alpha$)n$\Phi$}로 표현된다.

  • PDF

임플랜트 Overdenture의 Bar설계에 따른 하악지지조직의 광탄성학적 응력분석 (PHOTOELASTIC STRESS ANALYSIS ON THE MANDIBLE CAUSED BY IMPLANT OVERDENTURE)

  • 강정민;방몽숙
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.327-353
    • /
    • 1994
  • This study was performed to evaluate the effects of number and alignment of implant fixture and various bar designs on the retention of denture and the stress distribution. Six kinds of photoelastic mandibular models and nine kinds of overdenture specimens were designed. A unilateral vertical load was gradually applied on the right first molar to calculate the maximal dislodgement load of each specimen. A unilateral vertical load of 17 Kgf was applied on the right first molar and a vertical load of 10 Kgf was applied on the interincisal edge region. The stress pattern which developed in each photoelastic model was analyzed by the reflection polariscope. The results obtained were as follows: 1. The maximal dislodgement load reversely increased with the distance from the loading point to the implant fixture, while it linearly increased with that from the most posterior implant fixture to the mesial clip. The maximal dislodgement load also increased with the use of a cantilever bar. 2. Under the posterior vertical load, the stress to the supporting tissue of the denture base increased with the distance from the loading point to the implant future. The stress concentration on the apical area of the implant future reversely increased with the distance from the loading point to the implant future. 3. In the overdentures supported by two implant fixtures under the posterior vertical load. the specimen implanted on lateral incisor areas with a cantilever bar exhibited more favorable stress distribution than that without a cantilever bar. The specimen implanted on the canine areas without a cantilever bar, however, exhibited more favorable stress distribution. 4. In the overdentures supported by three implant fixtures. the specimen implanted ell the midline and canine areas exhibited more favorable stress distribution than that implanted oil the midline and the first premolar areas. 5. In the overdentures supported by four implant fixtures. the specimen implanted with two adjacent implant fixtures exhibited more favorable stress distribution than that implanted at equal distance under the posterior vertical load. 6. Under the anterior vertical load, the overdentures supported by three implant fixtures exhibited stress concentration on the supporting structure of the middle implant future. In overdentures supported by two or four implant futures, no significant difference was noted in stress distribution between the types of bars. These results indicate that the greater the number of implant fixtures, the better the stress distribution is. A favorable stress distribution may be obtained in the overdentures supported by two or three implant fixtures, if the location and the design of the bar are appropriate.

  • PDF

2층 조적조의 지진하중에 의한 거동해석 및 균열평가 (Response Analysis and crack Pattern Evaluation of Two Story Masonry Structure under the seismic Load)

  • 김희철;이경훈
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.179-190
    • /
    • 1998
  • 현재 국내에는 조적조 건물에 대한 내진규준이 마련되어 있지 않다 반면 최근 들어 한반도에 발생하는 지진의 반도수는 계속증가하고 있어 조적조 건물에 대한 지진하중에 의한 평가가 이루어져야 한다. 본 연구에서는 2층 조적조 건물에 국내에서 발생 가능한 최대지진가속도인 0.12g의 지진하중을 적용한 유한요소해석법에 의한 방법으로 동적해석을 수행한 결과 2층에 비하여 1층에서 불안전한 거동이 발생하였다 특히 개구부 주위 및 테두리 보와 조적벽의 경계부분에서 허용응력을 초과하여 균열이 발생함을 알 수 있었다.

  • PDF

가정용 목재 펠릿 보일러에 대한 부분부하 운전 특성 (Part Load Performance Characteristics of Domestic Wood Pellet Boiler)

  • 강새별;김종진;김혁주;박화춘;최규성;심봉석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.103.1-103.1
    • /
    • 2010
  • Recently domestic wood pellet boilers are installed in rural and forestry houses. The fuel price per lower heating value of wood pellet is about 20 % lower than that of heating oil on July 2010. In spite of lower price of wood pellet, a few user of wood pellet boiler complain expensive fuel cost. One of this reason is inaccurate or improper air-fuel ratio setting of wood pellet boiler. O2 concentration of flue gas of domestic wood pellet boiler is about 9.7 % and there are few domestic wood pellet boiler which can control air-fuel ratio automatically. We tested a domestic wood pellet boiler in changing boiler thermal output and air-fuel ratio. The nominal boiler thermal output is 25 kW (21 500 kcal/h). We measured thermal efficiency and flue gas concentrations such as CO and NOx at each boiler thermal load with various air-fuel ratio. The results show that if air flow rate is the same as full load and part load, thermal efficiency of part load of 40 % drops about 7.7 %p compared to boiler full load case.

  • PDF

압전형 부하 센서링이 장착된 5축 절삭가공기의 고속 주축시스템 설계 (Design of High Speed Spindle for 5-Axis Machining Equipment Equipped with Piezo-Electric Load Sensoring)

  • 최현진;박철우;장은실;김충현;최성대
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.20-25
    • /
    • 2011
  • In this paper, we reviewed the spindle system's motor and bearing and its mode safety for optimal design of a high speed spindle system that exceeds DmN value of 1,500,000. We could verify that it has a separation margin during critical speed by performing critical speed analysis. Also, we have selected an optimal sensoring installation location and actually manufactured & installed the sensor by identifying the stress concentration position in the axial load through finite element analysis to install the built-in piezo electric type load sensor to the spindle housing that can measure and monitor the machining load during high speed rotation of the spindle. Reproducibility is also verified by calibrating the error through the sensor's sensitivity adjustment after comparing the output between the plate dynamoneters and the load sensor to confirm the reproducibility of the load sensor.

실하중 이력에 의한 조인트의 동적강도해석 (Dynamic Stress Analysis of joint by Practical Dynamic Load History)

  • 송준혁;강희용;양성모
    • 한국공작기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.118-123
    • /
    • 2001
  • Most structures of automobile are composed of many substructures connected to one another by various types of mechanical joints. In automotive engineering, it is important to study these connected structures under various dynamic farces for the evaluations of fatigue life and stress concentration exactly. It is rarely obtained the accurate load history of specified positions because of the errors such as modeling, measurement, and etc. In the beginning of design, exact load data are actually necessary for the fatigue strength and life analysis to minimize the cost and time of designing. In this paper, the procedure of practical dynamic load determination is developed by the combination of the principal stresses of F.E. analysis and experiment. Inverse problem and least square pseudo inverse matrix are adopted to obtain an inverse matrix of analyzed stresses matrix. Pseudo-Practical dynamic load was calculated for Lab. Test of sub-structure. GUI program(PLODAS) was developed for whole of above procedure. This proposed method could be extended to any geometric shape of structure.

  • PDF