• 제목/요약/키워드: Computerized tomography

검색결과 338건 처리시간 0.03초

Study the effect of strong magnetic storm on the ionosphere of August 2003 in the China region

  • Debao, Wen;Yunbin, Yuan;Jikun, Ou;Xingliang, Huo
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.2
    • /
    • pp.191-193
    • /
    • 2006
  • The ionospheric strom evolution process was monitored during the 18 August 2003 magnetic strom over China, through inversion of the ionospheric electron density from GPS observations. The temporal and spatial variations of the ionosphere were analysed as a time series of ionospheric electron density profiles. Results show that the main ionospheric effects of the storm over China under consideration are: the positive storm phase effect usually happens in the low latitudinal ionospheric; the negative storm phase effect occurs in the middle latitude, and the equatorial anomaly structure can be found as well.

  • PDF

MDCT 영상에서 간의 추출 (Segmentation of Liver on MDCT Image)

  • 서정주;류강민;양비;박종원
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 한국컴퓨터종합학술대회 논문집 Vol.32 No.1 (B)
    • /
    • pp.802-804
    • /
    • 2005
  • 제안된 연구에서는 기존의 일반 CT(Computerized tomography) 영상이 아닌 MDCT(Multi Detector CT) 영상을 이용하여 장기 추출에 관한 연구를 진행하였다. 조영제를 이용한 복부 MDCT 영상으로부터 모폴로지(morphology) 기법을 통해 간에 근접한 노이즈를 제거하고, 기존의 Otsu threshold를 개선하여 간의 명암값 분포를 구분할 수 있는 임계치를 구하였다. 찾아진 임계치를 이용하여 영상을 이진화하고, 최종적으로 위치정보를 이용하여 간에 해당하는 부분들을 추출하였다. 이러한 방식은 명암값과 위치정보를 이용하여 간을 추출한 후 다시 노이즈 문제를 해결하는 기존의 알고리즘과 비교했을 때, 처리 방식이 단순해지고 속도가 향상되었다. 추출된 간은 간 이식술이나 절제술에 필요한 간 내부의 혈관 인식과 간의 부분체적 계산 연구에 중요한 정보로 사용될 수 있을 것이다.

  • PDF

CT영상의 3차원 재구성 및 표현에 관한 연구 (A Study on the 3D Reconstruction and Representation of CT Images)

  • 한영환;이응혁
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.201-208
    • /
    • 1994
  • Many three-dimensional object modeling and display methods for computer graphics and computer vision have been developed. Recently, with the help of medical imaging devices such as computerized tomography, magnetic resonance image, etc., some of those object modeling and display methods have been widely used for capturing the shape, structure and other properties of real objects in many medical applications. In this paper, we propose the reconstruction and display method of the three-dimensional object from a series of the cross sectonal image. It is implemented by using the automatic threshold selection method and the contour following algorithm. The combination of curvature and distance, we select feature points. Those feature points are the candidates for the tiling method. As a results, it is proven that this proposed method is very effective and useful in the comprehension of the object's structure. Without the technician's responce, it can be automated.

  • PDF

방사선치료용 CT simulator와 진단용 CT의 구조 차이에 의한 CT number의 비교 평가 (Evaluation of CT Number Difference between Radiation Therapeutic CT Simulator and Conventional CT)

  • 서정민;임재동;김찬형
    • 대한안전경영과학회지
    • /
    • 제17권3호
    • /
    • pp.215-219
    • /
    • 2015
  • The purpose in this study is to investigate CT number difference between conventional CT and CT simulator. It shows good correlation in CT number on the muscle, bone, and air. However, in the liver, lungs and water, the low correlation was detected. This result can become the good index for the direction of the distribution of dose difference research between CT equipment for using the computerized radiation therapy planning system.

Application of Plate and Circumferential Wiring with Resin to Bilateral Mandibular Fractures in a Calf: Case Report

  • Yu, Yong;Kim, Namsoo;Heo, Suyoung
    • 한국임상수의학회지
    • /
    • 제37권6호
    • /
    • pp.363-366
    • /
    • 2020
  • A 2-month-old, 50 kg male Korean native calf was referred with bilateral mandibular fractures. The bilateral mandible was hanging loose, with inability to use the jaw, indicated by excessive salivation. Radiography revealed a long oblique fracture in the right mandible, and a short oblique fracture in the left mandible. Computerized Tomography, a different form of radiography, revealed the fracture in the left mandible to be a comminuted fracture. In order to stabilize the bilateral mandible fractures, a combination of bone plate and wiring was applied; in addition, resin was applied to enhance stabilization of the mandible. Six weeks after surgery, the calf was able to masticate and ruminate well. In this case, application of the plate and wiring with resin to bilateral mandibular fractures presented a successful functional recovery. Accordingly, the combination of bone plate and wiring with resin can be an effective technique for treating mandibular fractures.

치과 콘빔 전산화단층검사 시 보루스 차폐체를 이용한 갑상선의 방사선 차폐효과 (Radiation Protective Effect of the Thyroid Gland Using Bolus Protector in the Dental Cone Beam Computed Tomography)

  • 이태희;정승훈;김동우;박명환;김태형
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.459-464
    • /
    • 2019
  • 치과 콘빔 전산화단층 검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위하여 보루스 (Bolus)를 이용한 차폐체를 제작하고, 방사선 차폐 효과와 영상의 적정성을 평가하였다. 치과용 콘빔 전산화단층검사장비를 사용하여 치과방사선 두부 팬텀을 대상으로 갑상선의 좌, 우측 부위에 유리선량계를 부착시켜 방사선량을 측정하였다. 차폐체의 두께를 각각 10 mm, 20 mm, 30 mm로 다르게 하여 각 차폐체별로 흡수선량을 측정하여 차폐체를 사용하지 않았을 경우와 비교하였다. 8명의 평가자가 진료영상의 적정성을 여부를 평가하였다. 왼쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 결과값이 평균 $342.67{\mu}Gy$로 Bolus 차폐체를 사용하지 않고 측정한 결과값의 평균 $431.22{\mu}Gy$보다 20.7% 감소하였고, 오른쪽 갑상선 부위에 30 mm Bolus 차폐체를 사용한 경우에는 평균 $424.56{\mu}Gy$로 21.9%의 선량감소효과를 보였다. 진료 영상의 적정성은 평가자 모두 사용 가능하다 판단하였다. 결론적으로, 치과 콘빔 전산화단층검사 시 갑상선 부위의 방사선 피폭선량을 최소화하기 위해 제작된 Bolus 차폐체는 장해음영 없이 적정한 진단 영상 처리가 가능하고, 방사선차폐 효과가 있어 유용한 차폐체로 적용 가능할 것으로 사료된다.

컴퓨터 영상을 이용한 임플란트 식립부위의 골밀도와 조직학적 연구 (BONE DENSITY AND HISTOMORPHOMETRY ASSESSMENT OF DENTAL IMPLANT USING COMPUTERIZED TOMOGRAPHY)

  • 손장호;최병환;박수원;조영철;성일용;이지호;변기정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.136-142
    • /
    • 2009
  • Bone density in the recipient implant site seems to be an important factor for long term success of endosseous implants. Preoperative evaluation of bone density is very helpful to assist the clinician with the treatment planning of implant therapy. Accurate information on bone density will help the surgeon identify suitable implant sites, thereby improving the success rate of the procedure. Purpose; The aim of this study was to evaluate a correlation between bone density measured preoperatively with computerized tomography and histologically measured bone density by bone biopsy. Patients and methods; Twenty seven patients were selected. All the patients were in good health, with no systemic disorder and additional bone graft. Preoperatively the patients underwent CT scanning to evaluate Houmsfield Unit(HU). Each patients wore a surgical template for implant placement. During surgery 2mm in diameter and 6mm in length specimens were taken. Histomorphometric analysis was performed using digitalized image analysis software Axiovision 4.3. Also, the Resonance frequency analysis(RFA) and insertion torque values were recorded. Results; The highest histomorphometric values was found in the posterior mandible $32.3{\pm}3.8$, followed by $29.9{\pm}2.6$ for the posterior maxilla, $29.4{\pm}2.6$ for the anterior maxilla, $28.6{\pm}2.3$ for the anterior mandible(p=0.214). The hounsfield unit was $989.2{\pm}258.1$ in the posterior mandible, $845.0{\pm}241.5$ in the anterior maxilla, $744.5{\pm}92.6$ in the anterior mandible, $697.3{\pm}136.9$ in the posterior maxilla(p=0.045). This results may suggest that there are strong correlation between the histomorphometric values and hounsfield unit(r=0.760, p<0.05). The RF measurements were $81.9{\pm}2.4$ ISQ in the posterior mandible, $79.0{\pm}1.4$ ISQ in the anterior mandible, $78.3{\pm}4.6$ ISQ in the posterior maxilla, $76.5{\pm}5.0$ ISQ in the anterior maxilla(p=0.048). The insertion torque values was $43.2{\pm}4.2\;Ncm$ in the posterior mandible, $42.0{\pm}0.0\;Ncm$ in the anterior mandible, $41.3{\pm}4.1\;Ncm$ in the posterior maxilla, $40.8{\pm}3.8\;Ncm$ in the anterior maxilla(p=0.612). This results may suggest that there are statistical significance between the hounsfield unit and the insertion torque values(r=0.494, p<0.05), the histomorphometric values and the insertion torque values(r=0.689, p<0.05). But there was no correlation between histomorphometric values and ISQ. There was no statistical significance in age and gender effect on parameters. Conclusions; There was significant correlations between bone density and implant stability parameters. The bone density measurements using preoperative CT may help clinicians to predict primary stability before implant insertion, which is associated with implant survival rates.

발생 중인 쥐 절치의 생물학적 광화 소요 시간 (Estimated Time of Biomineralization in Developing Rat Incisors)

  • 박민경;민수영;송제선;이제호;정한성;김성오
    • 대한소아치과학회지
    • /
    • 제44권2호
    • /
    • pp.138-146
    • /
    • 2017
  • 이 연구의 목적은 쥐의 하악 절치에서 생물학적 광화에 대한 발육 단계를 타임테이블로 수립하는데 있다. 맹출 길이가 측정되었고 조직학적 절편과 미세단층촬영기(microscopic computerized tomography) 단면으로 절치 발육의 4단계 (1) preodontoblast, (2) dentin matrix secretion, (3) enamel matrix secretion, 그리고 (4) enamel calcification을 확인하였다. 쥐의 하악 절치에서 총 맹출 속도는 $600{\pm}70{\mu}m/day$ ($mean{\pm}SD$; n = 12) 였다. 법랑질 분비 길이는 조직학적 절편에서 $4.59{\pm}0.75mm$, 방사선학적 단면에서 $3.64{\pm}0.63mm$였고 이를 각각 속도로 환산하면 $180.4{\pm}30.0hours$, $145{\pm}25hours$ 으로 나타났다(n = 24). 이러한 결과들은 쥐의 절치의 생물학적 광화가 일어나는 발육 4 단계가 단 며칠 만에 이루어진다는 것을 제시한다. 이번 동물 실험연구의 결과는 발육 중인 치배의 빠른 광물화 과정을 치아 발육 기간의 분석을 통해 이해할 수 있다는 것에 의의가 있다.

흉부외상 환자에 대한 전산화 단층촬영의 효용성 (The efficacy of computerized tomographic scan for chest trauma)

  • 노환규;최호;김영진;김정태;소동문;류한영;이철주
    • Journal of Chest Surgery
    • /
    • 제31권3호
    • /
    • pp.298-303
    • /
    • 1998
  • 초기에 외상성 뇌병변의 진단에 국한되었던 단층 촬영은 전산화 단층 촬영기가 널리 보급됨에 따라 흉부, 복부 및 척추, 그리고 안면부나 골반부의 외상에 의한 병변의 진단에 널리 이용되고 있다. 본 연구는 1년간 응급실에 내원한 흉부외상 환자 중 흉부의 전산화 단층 촬영을 시행한 134명의 환자를 대 瓚막\ulcorner단순 흉부 엑스선 촬영의 결과와 단층 촬영 결과를 비교, 분석함으로 외상 환자에게 사용되고 있는 흉부 전산화 단층 촬영의 효용성을 알아보고자 하였다. 분석 결과 134명의 환자 중 45명은 단순 흉부 엑스선 촬영 소견이 정상인데 단층 촬영을 시행받은 환자였고, 이중 24명은 단층 촬영 결과 역시 정상 소견을 보였다. 단층 촬영의 기흉과, 혈흉을 포함한 늑막삼출에 대한 진단률을 100%라고 가정할 때 단순 흉부 엑스선 촬영의 기흉과 늑막 삼출의 진단률은 각각 46.2%, 62.9%로 낮은 진단율을 보였다. 전체 환자 중 흉관 삽관을 받은 환자는 63명이었는데 이중 45명(71.4%)이 단순 흉부 엑스선 촬영만으로 흉관 삽관을 결정한 환자여서 치료 방침의 결정에는 단순 촬영의 효용성이 다소 높았다. 따라서 본 연구에 흉부 외상에 대한 전산화 단층 촬영이 다소 남용되고 있음이 확인이 되었으나 단층 촬영은 소량의 기흉이나 종격동의 병변등, 임상적으로 중요하면서도 단순 촬영이 제공할 수 없는 병변의 진단에 결정적으로 유용하며 그 효용성 또한 높다고 할 수 있다.

  • PDF

고지방식이 수컷 micro-pig에서 경신강지환(經身降脂丸) (GGEx)의 고지혈증 개선효과 (Anti-hyperlipidemia Effect of Gyeongshingangjeehwan (GGEx) in High Fat induced Obese Male Micro-pigs)

  • 양유인;정양삼;이희영;이상달;김병출;김종훈;석화준;유재상;윤기현;조주흠;김훈;김경철;신순식
    • 대한한의학방제학회지
    • /
    • 제14권2호
    • /
    • pp.45-56
    • /
    • 2006
  • Objectives : We evaluated anti-hyperlipidemia effect of Gyeongshinganjeehwan (GGEx) in high fat induced obese male micro-pigs. Methods : 7 month-old micro-pigs are fed with normal (n = 3) or high fat diet (n = 18) for 12 weeks. The pig revealed obesity in high fat diet were divided into 2 groups (n = 5 each) and vehicle (OMP) and Gyeongshingangjeehwan (GGEx, 616.7 mg/kg/day) were administrated for 1 month. We monitored the changes in body weight and measured plasma cholesterol, triglyceride, free fatty acid, GOT and, GPT after 1 month. The visceral fat were measured with computerized tomography and weights of various organs were measured after sacrifice. Results : 1. GGEx group had significantly reduced body weight gain than obese control group in statistics. 2. GGEx group didn't significantly differ from obese control group in blood total cholesterol, blood LDL-cholesterol, blood triglyceride. but it's data were similar to normal control group. 3. GGEx group had prominantly reduced visceral fat than obese control group in computerized tomography. 4. Blood GOT and GPT didn't differ from between groups. The organ weight were not significant different. And it is normal in size and colour of visceral organs. Conclusions : It is concluded that GGEx has anti-hyperlipidemia effect by improving visceral fat and access to security.

  • PDF