• Title/Summary/Keyword: Computer-aided Design

Search Result 1,322, Processing Time 0.025 seconds

Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report (심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고)

  • Cho, Jun-Ho;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.495-505
    • /
    • 2019
  • This study reported the treatment of a patient with excessive worn dentition and limited maxillo-mandibular space for restoration, utilizing the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. After the thorough examination of the patient's occlusal vertical dimension (OVD), full mouth rehabilitation was planned with increase of the OVD. The patient was satisfied with the provisional restorations establishing the increased OVD. The horizontal and vertical data of the patient's jaw relation that the provisional restorations contained were transferred to the definitive metal ceramic fixed prostheses by double scanning and three-dimensional printing. After the fixed restorations were cemented to the abutments, electronic surveying and three-dimensional printing were used to fabricate metal frameworks for the patient's removable partial dentures. The mandibular definitive removable prostheses were delivered to the patient's mouth and the full mouth rehabilitation procedures were completed. The digital technologies used for this case produced fixed and removable restorations satisfactory in masticatory, phonetic and aesthetic functions to both the patient and the dental clinician.

Computer-Aided Design of Involute Cylindrical Gears for Power Transmission (컴퓨터를 이용한 동력전달용 인벌류우트 원통치차의 설계)

  • 정태형;김민수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.594-602
    • /
    • 1990
  • A computer-aided design system of involute cylindrical gears(spur and helical gears) for power transmission is developed, in which the volume of a gear unit is minimized with satisfying various design constraints. As the design constraints, bending strength and pitting resistance of AGMA 218.01, scoring of Dudley's flash temperature, contact ratio, and involute interference of pinion are considered and effective factors for strength calculation(life, reliability, hardness ratio, load distribution, velocity, etc.) are also included. This complicated nonlinear optimization problem is solved by using ALM(Augmented-Lagrange-Multiplier) method with self scaling BFGS(Broydon-Fletcher-Goldfarb-Shanno) method employed for unconstrained optimization programming. This design method can be easily applied to designing power transmission gear unit in the machines of various kinds. It is expected for the proposed method to be a contribution for an automated design of gear unit towards weight minimization, miniaturization and high strength of gear unit.

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

Current status and future perspectives of CAD/CAM fabricated complete denture (임상가를 위한 특집 2 - CAD/CAM 기술을 이용한 총의치 제작의 현재와 전망)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.346-353
    • /
    • 2014
  • Currently, computer-aided technology becomes one of main issues in clinical dentistry. About 25 years ago, the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures leads to be able to fabricate complete denture today. The fabrication of milled complete denture prostheses with digital scanning technology may decrease the number of patient appointments. However, the precise tooth arrangement and evaluation by patient is not promising relatively. The purpose of this review was to analyze the existing literature on computer aided technology for fabricating complete denture with historical background, current status, and future perspectives. In addition, two available commercial systems were introduced.

Computer Aided Engineering Design of Power Injection Molding Process for Dental Scaler Top Mold Design

  • Hwang, C.J.;Ko, Y.B.;Park, H.P.;Chung, S.T.;Rhee, B.O.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.497-498
    • /
    • 2006
  • Powder Injection Molding (PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry. With this regards, design technology of dental scaler tip PIM mold, which has complex shape, with the help of computer-aided analysis for powder injection molding process was developed. Compter aided analysis results, such as filling pattern, weldline formation, and air vent position prediction were investigated and eventually showed good agreements with experimental results.

  • PDF

Systematization design and the analogical interpretation of machinery character by use CAE (컴퓨터 응용기술(CAE)을 이용한 기기특성의 유추해석과 계열화 설계)

  • 조경재;조제황;이권현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.851-856
    • /
    • 1996
  • In this paper, we introduce the design method using CAE(Computer Aided Engineering) which is profitable in the compatability and standardization of the developed product, and the reduction of construction time and price to develop and design a machine equipment. Particularly, we select the standard model to design or develop from the large machinery to the super precision one, extract the peculiar characters of the model by the close analysis of the physical and technical part, the experiment for the characteristics of objective dimensions by analogical mathematical analysis for previous results, and can induce the design model demanded by user investigating optimal data in the design previous We present the analogical algorithms and process method of design factors and restriction factors in the systematization design with computer. Then we analyze step functions for each systematization equipment and induce the process of technical data with actuator model.

  • PDF

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Use of the surface-based registration function of computer-aided design/computer-aided manufacturing software in medical simulation software for three-dimensional simulation of orthognathic surgery

  • Kang, Sang-Hoon;Lee, Jae-Won;Kim, Moon-Key
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.197-199
    • /
    • 2013
  • Three-dimensional (3D) computed tomography image models are helpful in reproducing the maxillofacial area; however, they do not necessarily provide an accurate representation of dental occlusion and the state of the teeth. Recent efforts have focused on improvement of dental imaging by replacement of computed tomography with other detailed digital images. Unfortunately, despite the advantages of medical simulation software in dentofacial analysis, diagnosis, and surgical simulation, it lacks adequate registration tools. Following up on our previous report on orthognathic simulation surgery using computer-aided design/computer-aided manufacturing (CAD/CAM) software, we recently used the registration functions of a CAD/CAM platform in conjunction with surgical simulation software. Therefore, we would like to introduce a new technique, which involves use of the registration functions of CAD/CAM software followed by transfer of the images into medical simulation software. This technique may be applicable when using various registration function tools from different software platforms.