In this study, we investigated the rotational characteristics which were comprised of directionality and linearity of target registration error (TRE) as a study in advance to enhance the accuracy of contour-based registration in neuronavigation. For the experiment, two rigid head phantoms that have different faces with specially designed target frame fixed inside of the phantoms were used. Three-dimensional coordinates of facial surface point cloud and target point of the phantoms were acquired using computed tomography (CT) and 3D scanner. Iterative closest point (ICP) method was used for registration of two different point cloud and the directionality and linearity of TRE in overall head were calculated by using 3D position of targets after registration. As a result, it was represented that TRE had consistent direction in overall head region and was increased in linear fashion as distance from facial surface, but did not show high linearity. These results indicated that it is possible for decrease TRE by controlling orientation of facial surface point cloud acquired from scanner, and the prediction of TRE from surface registration error can decrease the registration accuracy in lesion. In the further studies, we have to develop the contour-based registration method for improvement of accuracy by considering rotational characteristics of TRE.
Park, Jung-Eun;Bae, Seon-Hye;Choi, Young-Jun;Choi, Won-Cheul;Kim, Hye-Won;Lee, Ui-Lyong
Maxillofacial Plastic and Reconstructive Surgery
/
제39권
/
pp.22.1-22.9
/
2017
Background: Two-jaw surgery including mandibular and maxillary backward movement procedures are commonly performed to correct class III malocclusion. Bimaxillary surgery can reposition the maxillofacial bone together with soft tissue, such as the soft palate and the tongue base. We analyzed changes of pharyngeal airway narrowing to ascertain clinical correlations with the prevalence of snoring after two-jaw surgery. Methods: A prospective clinical study was designed including a survey on snoring and three-dimensional (3D) computed tomography (CT) in class III malocclusion subjects before and after bimaxillary surgery. We conducted an analysis on changes of the posterior pharyngeal space find out clinical correlations with the prevalence of snoring. Results: Among 67 subjects, 12 subjects complained about snoring 5 weeks after the surgical correction, and examining the 12 subjects after 6 months, 6 patients complained about the snoring. The current findings demonstrated the attenuation of the largest transverse width (LTW), anteroposterior length (APL), and cross-sectional area (CSA) following bimaxillary surgery given to class III malocclusion patients, particularly at the retropalatal level. The average distance of maxillary posterior movements were measured to be relatively higher (horizontal distance 3.9 mm, vertical distance 2.6 mm) in case of new snorers. Conclusions: This study found that bimaxillary surgery could lead to the narrowing of upper airway at the retropalatal or retroglossal level as well as triggering snoring in subjects with class III malocclusion. Based on the current clinical findings, we also found that upper airway narrowing at retropalatal level may contribute to increasing the probability of snoring and that polysonography may need to be performed before orthognathic surgery in subjects with class III malocclusion.
서양인에 비해 한국인에서 호발 하는 III급 부정교합은 함몰된 중안모와 더불어 돌출된 하순과 하악골로 인해 기능적, 심미적, 심리적 문제를 야기하게 된다. 이러한 인종적 특성에 따른 발생 빈도의 차이에 따라 기존의 연구들은 주로 nasal airway 폐쇄와 II급 부정교합과의 관계에 대한 것이 대부분이었다. 또한 이러한 연구들은 자료 채득이 용이한 반면 2차원적 한계를 가지고 있는 측모 두부방사선 계측사진을 이용한 연구가 대부분이었다. 이에 본 연구는 III급 부정교합자와 정상교합자의 nasal airway의 형태를 3차원 전산화 단층촬영을 통해 얻어진 입체 영상으로 재구성한 모델을 이용하여 비교해 보고자 시행되었다. 연구 대상으로서 실험군으로 골격성 III급 부정교합으로 진단되어 악교정 수술을 위한 술 전 교정치료를 받기로 예정된 총 16명(남성 7명,여성 9명)과 대조군으로 임상적으로 정상적인 교합관계를 보이며 교정치료와 보철치료의 경험이 없는 정상 교합자 13명(남성 7명,여성 6명)을 선정 하였다. 두개골의 전산화 단층촬영(Computed Tomograph / CT)을 시행한 후 얻은 영상정보를 이용하여 nasal airway와 두개골의 3차원 입체영상을 제작하였다. 이러한 입체영상을 가지고 nasal airway의 절대적, 상대적 부피, 단면적의 비교를 시행하였으며 결과는 다음과 같았다. 1. 두 군 사이에 절대적 상기도 부피 비교에 있어서 실험군의 구인두 크기가 대조군에 비해 크게 나타났으며, 나머지 항목에서는 두 군 사이에 유의한 차이가 나타나지 않았다. 2. 두 군 사이에 상대적 상기도 부피 비교에 있어서 실험군의 구인두 부피가 대조군에 비해 크게 나타났으며, 나머지 항목에서는 두 군 사이에 유의한 차이는 나타나지 않았다. 3. 두 군 사이에 구인두 폭경변화 양상은 유사하게 나타나 하방으로 갈수록 점점 감소하다 다시 증가하는 양상을 보였으며 모든 부위에서 대조군에 비해 실험군의 평균 폭경이 크게 나타났다. 4. 측면에서의 상기도 평균 기도 만곡도를 나타내는 그래프 상에 있어서 두 군 사이에 유사한 양상이 나타났다.
목 적 : 정위적체부방사선치료(Stereotactic Body Radiation Therapy, SBRT)를 시행하는 폐암환자의 호흡 변화에 따른 종양 움직임의 재현성을 비교 분석하고, 치료 중 환자 호흡의 안정도를 확인하여 호흡 신호 확인 과정의 유용성을 평가하고자 한다. 대상 및 방법 : 호흡연동방사선치료(Respiratory Gated Radiation Therapy, RGRT)를 실시한 30명과 RGRT를 시행하지 않는 30명을 그룹1, 2로 정하고, 4-Dimensional Computed Tomography (4-DCT), Cone-Beam CT (CBCT), 투시 영상에서 측정한 종양의 움직임 차이를 비교하였다. 그룹2를 대상으로 치료 중 호흡의 안정도를 확인하기 위해서 Real-time Position Management (RPM) System (version 1.7.5, Varian, USA)을 이용하여 호흡 신호의 기준 구간을 설정하고 치료 중 환자의 호흡이 정해진 구간에서 벗어난 횟수를 측정하였다. 결 과 : 4DCT에서 측정한 평균 움직임과 CBCT에서 평균 움직임의 차이가 그룹1은 전 후 방향, 축 방향, 측 방향 각각 1.0 mm, 1.1 mm, 1.9 mm, 그룹2는 0.3 mm, 0.9 mm, 0.4 mm로 확인되었다. 4DCT와 투시 영상의 축 방향에 대한 평균 움직임 차이는 그룹1에서 0.6 mm, 그룹2에서는 2.3 mm였고, CBCT와 투시 영상의 축 방향에 대한 차이는 그룹1에서 1.7 mm, 그룹2에서 1.4 mm의 차이를 보였다. 그룹2에서 1회 치료(15Gy)를 시행하는 동안 호흡 기준을 벗어나지 않고 치료가 시행된 경우는 대상 환자 30명의 총 120회 중 32회였고, 가장 많이 벗어난 환자는 1회 치료 시 최대 108번 설정 기준을 벗어난 것으로 확인되었다. 결 론 : 전체 대상 환자의 종양 움직임은 각각의 영상에서 평균적으로 5 mm 미만의 차이를 보였지만 특정 환자의 경우 13 mm이상의 차이가 있었고, RGRT를 적용하지 않은 환자들의 치료 중 호흡이 불안정한 것을 확인할 수 있었다. 본 연구를 통하여 고 선량이 전달되는 폐암 환자의 SBRT 시 RGRT를 적용하지 않는 환자에 대해서도 종양 움직임을 확인하고 RPM system 을 이용한 치료 중 호흡 관찰을 실시한다면, 치료 중 계획된 선량 전달의 정확성을 높일 수 있을 것으로 사료된다.
본 연구는 선형가속기의 회전불균형의 영향으로 발생 되는 CBCT 영상의 setup 오차 변화를 분석하여, 회전불균형에 대한 정도관리의 필요성을 연구 하였다. CBCT 시스템의 3차원 체적영상모드를 이용하여 $360^{\circ}$ 회전과 $180^{\circ}$ 회전으로 Catphan503 팬텀과 균질 팬텀의 3차원 영상을 획득하였고, setup 오차를 측정하기 위해 나선형 CT의 기준영상과 함께 비교 분석 하였다. 표준 정도관리의 절차를 시행하여 정상적인 상태를 확인하고, 임의적으로 갠트리의 회전균형을 조절한 후, 균형상태와 불균형상태의 각각 CBCT 영상에 대하여 X, Y, Z, Roll, Pitch, and Yaw의 6차원적 관점에서 setup 오차를 측정하고 분석하였다. Setup 오차의 변화율은 갠트리 회전균형의 조정 전 후를 확인한 결과, 직교 좌표계는 $360^{\circ}$의 회전에서 X축 방향으로 0.6 mm, Y축 방향으로 0.5 mm, Z축 방향으로 0.5 mm의 최대 변화율을 보였다. $180^{\circ}$의 회전은 X축 방향으로 0.9 mm, Y축 방향은 0.2 mm, Z축 방향은 0.3 mm의 최대 변화율을 보였다. 또한 회전 변환계는 회전 불균형이 커질수록 평균적인 값의 차이가 점점 증가하였고, 최대값은 $1.1^{\circ}$를 나타내었다. 영상의 분해능은 균형 조정 전 후 영상분석 툴에서 2 lp/cm 차이를 나타내었다. CBCT 시스템의 정도관리는 기준 권고안을 만족하였다. 갠트리의 회전 불균형이 클 때, setup 오차의 직교 좌표계의 변화는 크지 않았으나, 회전 변환계의 변화율은 기준 권고 값인 $1^{\circ}$에 해당하는 값과 초과하는 $1.1^{\circ}$를 나타내었다. 이는 갠트리의 불균형이 setup 오차에 영향을 미치는 것을 알 수 있었으며, 또한 회전 변환계의 setup 오차에 대한 6차원적인 보정이 더욱 요구됨을 알 수 있다. 그러므로 정확하고 정교한 영상유도 방사선치료를 수행하기 위해서는 갠트리의 균형도를 확인해야 하며, 정도관리 항목으로 추가되어야 한다고 사료되어진다.
하악 과두의 발달과 증식은 측두하악관절 부위의 생역학적 환경의 변화에 따라 변경될 수 있다. 이 부위에 전달되는 생역학적 하중은 섭취하는 음식물의 경도를 다르게 함으로써 변화시킬 수 있다. 이번 연구의 목적은 성장 중인 쥐에서 부드러운 음식물의 섭취에 의해 저작력을 변화시키는 것이 하악 과두의 해면골의 형태를 변화시킬 수 있는지 미세전산화 단층촬영을 이용하여 분석하는 것이었다. 생후 21일 된 C57BL/6 쥐 36마리를 무작위로 두 그룹으로 나누었다. 8주 동안 대조군의 쥐들은 일반적인 딱딱한 덩어리의 사료를, 실험군의 쥐들은 덩어리의 사료를 잘게 갈은 후 물과 섞어 부드럽게 만들어 먹였다. 또한 실험군의 쥐들의 하악 절치를 일주일에 두 번씩 잘라서 짧게 만들었다. 8주 후 모든 쥐들을 희생하여 우측 하악 과두를 준비하였다. 미세전산화 단층촬영과 삼차원 영상 분석프로그램을 이용하여 하악 과두 해면골의 bone volume(BV), bone surface(BS), total volume(TV) bone volume fraction(BV/TV), surface to volume ratio(BS/BV), trabecular thickness(Tb. Th.), structure model index(SMI)와 degree of anisotropy(DA)를 측정하고 이들 값으로부터 trabecular number(Tb. N.)와 trabecular separation (Tb. Sp.)을 계산하였다 미세전산화 단층영상을 얻은 후 하악 과두의 조직 표본을 만들었다. 연구 결과는 다음과 같았다. 1. Bone volume fraction(BV/TV), trabecular thickness(Tb. Th.)와 trabecular number(Tb. N.)가 대조군에 비해 부드러운 음식을 먹인 실험군에서 유의하게 감소되었다(p<0.05). 2. Trabecular separation(Tb. Sp.)은 부드러운 음식을 먹인 실험군에서 유의하게 증가하였다(p<0.05). 3. Surface to volume ratio(BS/BV), structure model index(SMI), degree of anisotropy (DA)는 두 군 사이에 유의한 차이를 보이지 않았다(p>0.05). 4. 조직 절편을 관찰한 결과, 부드러운 사료를 먹인 실험군에서 하악 과두의 연골층의 증식 층과 전체 두께가 상당히 감소하였다.
Torres, Fernanda Ferrari Esteves;Jacobs, Reinhilde;EzEldeen, Mostafa;de Faria-Vasconcelos, Karla;Guerreiro-Tanomaru, Juliane Maria;dos Santos, Bernardo Camargo;Tanomaru-Filho, Mario
Imaging Science in Dentistry
/
제50권2호
/
pp.161-168
/
2020
Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 ㎛, as well as different software tools(post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test(P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 ㎛. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 ㎛, and for Biodentine at 20 ㎛. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.
전산화단층검사는 많은 방사선을 받을 수 있으며, 한 명의 환자에서 반복적으로 시행되는 경우가 위험도는 매우 높다. 어린이의 경우에 방사선에 의한 암 발생률이 더 높다고 보고하고 있다. 3D 프린트는 여러 분야에 적용하기 위해서 연구되고 있으며, 여러 응용 분야중 방사선 차폐체 제작 및 재료에 대한 연구가 최근 진행되고 있다. 3D 프린터의 목적은 기존의 판넬 형태의 차폐체를 대체하고 인체의 형태를 따라 맞춤형 제작을 하는 것이 최종 목적이기 때문에 3D 프린터에 입력할 3차원정보처리에 대한 연구도 매우 중요하다. 본 연구에서는 스테레오 비전의 깊이지도(depth map) 생성 기술을 이용하여 환자 맞춤형 안구차폐체 제작의 전단계인 인체표면의 3차원 데이터를 계산하고 활용 가능성을 연구하고자 하였다. 알려진 3차원 정보처리의 방법들에 비해서 비교적 간단한 방법으로 제안된 결과 안면부 3차원 정보추출을 위한 최소한의 정보가 추출되었다. 본 연구의 결과는 자연광을 적용한 스테레오영상의 장점과 한계점을 제공하였고 향후 안구 차폐체 제작을 위한 기초자료가 될 것으로 판단한다.
The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.
MDCT의 3D 유용성을 입증하기 위해 쇄골하 혈전증을 수반한 73세 남자 환자를 대상으로 MIP, 볼륨렌더링, MPR의 3D 영상을 획득하여 쇄골하동맥의 혈전증을 명확하게 탐지하고 위치를 확인하여 임상에서 기초자료를 제공하여 환자의 진단 및 치료에 적용하고자한다. 스캔 데이터를 3차원 CT영상인 MIP, 볼륨렌더링, curve multiplanar reformation (MPR), virtual endoscopy 영상을 획득하였다. CT검사 환자의 데이터를 3D 프로그램으로 전송한 영상에서 3D 프로그램에서 측정한 상행대동맥은 364.28 HU, 좌총경동맥 413.77 HU, 좌쇄골하동맥 15.72 HU로 낮게 산출되었다. MIP coronal 영상으로 좌측의 쇄골하동맥의 혈전으로 폐쇄를 정확하게 보여주고 있다. 볼륨렌더링 3차원 영상으로 투과도 100%, 87-1265 HU를 적용하여 쇄골하동맥과 뼈를 동시에 묘출하고 있으며, 좌측 쇄골하동맥의 폐쇄 영상을 선명하게 보여주었으며 coronal curved MPR 및 sagittal curved MPR 영상으로 혈전의 의한 쇄골하동맥의 폐쇄를 3D 영상 처리 기능을 이용하여 정확하게 묘출하고 있다. 혈전에 의한 쇄골하동맥 폐쇄 증상 환자를 MDCT로 스캔하여 3D 영상 기법을 응용하여 쇄골하동맥의 폐쇄를 확인할 수 있어 임상에서 3D 기법을 응용하여 적절하게 진단에 적용할 수 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.