Browse > Article
http://dx.doi.org/10.7742/jksr.2019.13.7.955

Preliminary Research on the Implementation of Information of Human Facial Part Required for the 3D Printing of Eye Shield  

Choi, Seokyoon (Department of Radiological Science, Catholic University of Pusan)
Publication Information
Journal of the Korean Society of Radiology / v.13, no.7, 2019 , pp. 955-960 More about this Journal
Abstract
The Computed tomography (CT) scan can have high radiation in a few tests, and this risk is significant given that it is often repeated in one patient. In children, the incidence of radiation-induced cancer is reported because organs are growing, are more sensitive to radiation. 3D printing has recently been studied to be applied to various applications as a research field for 3D printing applications, research on fabrication of radiation shields and materials has been conducted. The purpose of the 3D printer is to replace the existing panel-type shields and to make customized designs according to the shape of the human body. Therefore, research on 3D information processing to be input to the 3D printer is also necessary. In this study, 3D data of the human body surface, which is the preliminary step of the manufacture of patient-specific eye shield using stereo vision depth map technology, was studied. This study aims to increase the possibility of three-dimensional output. As a result of experimenting with this method, which is relatively simple compared with other methods of 3D information processing, the minimum coordinates for 3D information are extracted. The results of this study provided the advantages and limitations of stereo images using natural light and will be the basic data for the manufacture of eye shields in the future.
Keywords
Tube voltage; Slice thickness; Noise; Head CT;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Y. G. Kwak, C. Y. Kim, S. P. Jeong, "Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth," The Journal of the Korea Contents Association, Vol. 14, No. 8, pp. 233-242, 2014.   DOI
2 M. Y. Park, S. E. Jung, "CT radiation dose and radiation reduction strategies," J. Korean Med. Assoc., Vol. 54 No. 12, pp. 1262-1268, 2011.   DOI
3 H. J. Kim, "A study of beam hardening effect reduction occur in brain CT," Journal of the Korea Academia-Industrial cooperation Society, Vol. 16 No. 2, pp. 8479-8486, 2015.   DOI
4 C. H Lee, and C. S. Lim, "A study on Added Filters for Reduction of Radiation Exposure Dose in Skull A-P Projection," Journal of Korean Academia-Industrial cooperation Society Vol. 12, No. 7, pp. 3117-3122, 2011.   DOI
5 H. S. Kim et al,"An Assessment of the Usefulness of Aluminum Foil Shield to Reduce Eye Lens Radiation Dose in Computed Tomography," Journal of Advanced Engineering and Technology, Vol. 6, No. 1, pp. 25-28, 2013.
6 S. M. Kwon, J. S. Kim,"The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT," The Korean Society of Radiology, Vol. 9, No. 5, pp. 279-285, 2015.   DOI
7 I. G. Mun, S. H. Shin, "Study on the Development of an Outdoor Radiographic Test Shield Using 3D Printer Filament Materials," The Korean Society of Radiology, Vol. 13, No. 4, pp. 565-572, 2019.
8 http://kportal.kipris.or.kr/
9 E. J. Lee, J. H. Yoon, J. S. Park, "Computation of Dense Disparity Map and Hole Filling," Conference of Korean Information Science Society, Vol. 34, No. 2, pp. 424-427, 2007.
10 Y. I. Cho, "A Study on the Design Method of Radiation Shielding Devices Using 3D Printing Material," The Graduate School of Catholic University of Pusan, Ph.D. thesis pp.180-182, 2019.
11 S. Lee, K. S. Chon," Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan" ,The Korean Society of Radiology, Vol. 13, No. 2, pp 147-151, 2019
12 H. S. Son, S. Y. Lee, K. W. Min, "Hand Region Detection based on Stereo Vision Disparity Map," Korean Institute of Electronics Engineers Conference, 515-517, 2007.
13 H. W. Goo, "Pediatric CT: Understanding of Radiation Dose and Optimization of Imaging Techniques," J Korean Radiol Soc, Vol. 52, No. 1, pp. 1-5, 2005.   DOI