Effectiveness Assessment on the Soil Temperature of KMA as Ground Heat Source Using CFD in Pit Area (CFD를 이용한 기상청 지중온도의 피트부분 지중열원 유용성 평가에 관한 연구)

  • Min, Joon Ki;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.49-54
    • /
    • 2008
  • The experimental of temperature, humidity and velocity was taken from the underground pit which utilized the system of ground heat source quite similar to the cool-pit system. Also, through CFD analysis, one could review the effectiveness of analysis of future alternatives. Furthermore, the temperature range of mock up cool-pit system was analyzed by inputting the weather data of annual average soil temperature provided by KMA(Korea Meteorological Administration) into the fluid simulation of anticipated heat distribution. Firstly, the difference between the temperature of air exhaust of the pit or the temperature of air supply of the compressor room and the experimental data for the month of May from the CFD analysis came out to be $0.6^{\circ}C$ and $0.9^{\circ}C$ respectively with tolerance of 3.1% and 4.7%. Secondly, the difference between the temperature of air exhaust of the Pit or the temperature of air supply of the compressor room and the experimental data for the month of July from the CFD analysis came out to be $0.8^{\circ}C$ and $1.1^{\circ}C$ respectively with tolerance of 3.3% and 4.5%. Thirdly, for the month of May, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.9^{\circ}C$ and $1.8^{\circ}C$ respectively with tolerance of 10.7% and 9.8%. Fourthly, for the month of July, the difference between the experimental data taken for the air exhaust of the Pit or the air supply of the compressor room and soil temperature provided by KMA for monthly and yearly average temperature of Jeonju region came out be $1.1^{\circ}C$ and $1.4^{\circ}C$ respectively with tolerance of 4.5% and 5.8%. The result of above experiments allowed us to establish CFD model set up as a verification tool that is based on experimental data collected within the Pit area. Also, one could confirm the possibility to apply weather data of soil temperature provided by KMA in order to anticipate proper value for CFD analysis.

Study on Temperature Characteristics of Friction Stir Welding Process by Numerical Analysis (수치해석을 활용한 마찰교반용접 공정의 온도 특성 분석 연구)

  • Kim, Moosun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.513-518
    • /
    • 2019
  • Friction Stir Welding is a welding technique for metal materials that utilizes the heat generated by friction between the material to be welded and the welding tool that rotates at high speed. In this study, a numerical analysis method was used to analyze the change in the internal temperature of the welded material during friction stir welding. As the welding target material, AZ31 magnesium alloy was applied and the welding phenomenon was considered a flow characteristic, in which a melting-pool was formed. FLUENT was used as the numerical tool to perform the flow analysis. For flow analysis of the welding process, the welding material was assumed to be a high viscosity Newtonian fluid, and the boundary condition of the welding tool and the material was considered to be the condition that friction and slippage occur simultaneously. Analyses were carried out for various rotational speeds and the translational moving speed of the welding tool as variables. The analysis results showed that the higher the rotational speed of the welding tool and the slower the welding tool movement speed, the higher the maximum temperature in the material increases. Moreover, the difference in the rotational speed of the welding tool has a greater effect on the temperature change.

Numerical analysis for heat transfer and pressure drop characteristics of (다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석)

  • Hou, Rong-Rong;Park, Hyeong-Seon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.367-375
    • /
    • 2014
  • In numbers of kinds of heat exchanger, the shell-tube heat exchanger is the most commonly used type of heat exchanger in the industry field. In order to improve the thermal performance of the heat exchanger, this study was analyzed heat transfer characteristics according to arrangement of baffle and direction of baffle and bump phase of baffle about shell-tube heat exchanger using appropriate SST (Shear Stress Transport) turbulence model for flow separation and boundary layer analysis. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature of shell side was constantly 344 K and the variation of the water flow rate was 6, 12, 18 and 24 l/min. As the result of analysis, zigzag baffle arrangement enhances heat transfer rate and pressure drop. Furthermore, in the direction of the baffle, heat transfer rate is more improved with vertical type and angle $45^{\circ}$ type than existing type, and pressure drop was little difference. Also, the bump shape of baffle surface contributes to heat transfer rate and pressure drop improvement due to the increased heat transfer area. Through analysis results, we knew that the increase of the heat transfer was influenced by flow separation, fluid residual time, contact area with the tube, flow rate, swirl and so on.

Flow-Turbine Interaction CFD Analysis for Performance Evaluation of Vertical Axis Tidal Current Turbines (I) (수직축 조류 터빈 발전효율 평가를 위한 유동-터빈 연동 CFD 해석 (I))

  • Yi, Jin-Hak;Oh, Sang-Ho;Park, Jin-Soon;Lee, Kwang-Soo;Lee, Sang-Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.67-72
    • /
    • 2013
  • In this study, numerical analyses that considered the dynamic interaction effects between the flow and a turbine were carried out to investigate the power output performance of an H-type Darrieus turbine rotor, which is one of the representative lifting-type vertical-axis tidal-current turbines. For this purpose, a commercial CFD code, Star-CCM+, was utilized for an example three-bladed turbine with a rotor diameter of 3.5 m, a solidity of 0.13, and the blade shape of an NACA0020 airfoil, and the optimal tip speed ratio (TSR) and corresponding maximum power coefficient were evaluated through exhaustive simulations with different sets of flow speed and external torque conditions. The optimal TSR and maximum power coefficient were found to be approximately 1.84 and 48%, respectively. The torque and angular velocity pulsations were also investigated, and it was found that the pulsation ratios for the torque and angular velocity were gradually increased and decreased with an increase in TSR, respectively.

The Comparison of the In-Situ Thermal Response Tests and CFD Analysis of Vertical-type Geothermal Heat Exchanger (수직형 지중 열교환기의 현장 열응답 시험과 CFD 해석 비교)

  • Sim, Yong-Sub;Lee, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3164-3169
    • /
    • 2013
  • In this study, a series of CFD analysis was performed in order to predict the leaving water temperature and the slope of in-situ thermal response tests of the vertical-type geothermal heat exchangers. The geothermal heat exchanger and surrounding ground formation were modeled using GAMBIT and simulation was used by utilizing FLUENT which is commercial CFD code. Comparing with the results of CFD and in-situ thermal response tests, the results of CFD was presented good agreement with $0.5^{\circ}C$ difference of Leaving Water Temperature and with 1.6% difference of the Slope.

Flow Analysis over Moving Circular Cylinder Near the Wall at Moderate Reynolds Number (낮은 레이놀즈 수에서 벽면에 근접하여 이동하는 실린더 주위의 유동해석)

  • Kwag, Seung-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1091-1096
    • /
    • 2012
  • The aerodynamic characteristics of circular cylinder in a channel are studied to make clear the flow feature by solving the Navier-Stokes equation based on the finite volume method with unstructured grids. Reviews are made on with the vorticity, velocity, dynamic pressure, residual and drag, where the Reynolds numbers are 50 and 100. The flows for $Re{\succeq}50$ shows the vortex shedding in the wake, and the result is the same as the case of moving cylinder. The ground effect of flat bottom results in the growth of vortex, being generated in the upper side of the cylinder and elongated in the rear. As the cylinder approaches to wall, for example 0.6, the cylinder plays as a role of blockage to obstruct the flow between the cylinder and wall. The drag coefficients are compared with others' results to confirm the validity of the present numerical simulation.

Analysis of Natural Ventilation Characteristics of Venlo-type Greenhouse with Continuous Roof Vents (연속형 천창을 가진 벤로형 온실의 자연환기 특성 분석)

  • Kwon, Jin-Kyeong;Lee, Sung-Hyun;Seong, Jae-Hoon;Moon, Jong-Pil;Lee, Soo-Jang;Choi, Byeong-Min;Kim, Kyeong-Ja
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.444-452
    • /
    • 2011
  • In this study the characteristics of natural ventilation of Venlo-type greenhouse with continuous roof vents were analyzed using commercial computational fluid dynamics (CFD) code. Developed CFD simulation model was verified by comparison with experimental data. Simulation errors were 1.9-46.0% for air velocity and 1.7-11.2% for air temperature at each measurement point. CFD simulations were conducted to estimate the effect of roof vents opening direction, opening angle, outside wind velocity and wind directions on ventilation rate and climate condition in greenhouse. The results of this study showed that ventilation rate of the present greenhouse was increased linearly in proportion to the increase of roof vent opening angle and outside wind velocity over 2.0 m/s. According to the analysis on the effects of different roof vent opening direction, simultaneous opening of wind and leeward vents showed the highest ventilation rate and lowest mean temperature in greenhouse.

Modeling of a Rotor System Incorporating Active Tab and Analysis of BVI Noise Reduction Characteristics (능동 탭 로터 모델링 및 BVI 소음 저감 특성 해석)

  • Kim, Do-Hyung;Kang, Hee Jung;Wie, Seong-Yong;Kim, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.855-864
    • /
    • 2013
  • Active tab is one of the promising technology for the BVI (blade-vortex interaction) noise reduction, and analysis of noise reduction performance is very important phase of the technology development. For the purpose of analysing the performance of noise reduction using active tab, CAMRAD II model for a model-scale rotor system was constructed utilizing structural design result and airfoil aerodynamic data generated by CFD (computational fluid dynamics) calculation. HHC strategy was applied to descent flight condition and air-load was calculated by CAMRAD II then variations of BVI noise was calculated by in-house program. Calculation result with respect to tab length and control phase changes showed BVI noise could be reduced by -3.3dB.

Grid Dependency and Aerodynamic Analysis for Transonic Flow of Delta Wing using CFD (천음속영역의 삼각날개 격자의존성 및 공력해석)

  • Jeong, Kiyeon;Jung, Eunhee;Kang, Dong-Gi;Lee, Daeyeon;Kim, Dukhyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.6
    • /
    • pp.445-451
    • /
    • 2018
  • This paper describes on introduction of CASE 4(Delta Wing) for EFD-CFD comparison workshop which is in charged of aerodynamic subcommittee of The Korean Society for Aeronautical and Space Science. The wind tunnel test will be performed later, angle of attack is set -5~20deg and mach number is set 0.7, 0.85, 1.2 to solve the transonic flow. The simulation test of grid dependency is conducted to determine the proper grid size of delta wing analysis. The tendency of lift and drag coefficient is determined according to the change of angle of attack based on the selected grid size.

Development of a Cooling and Heating System for Greenhouse using Geothermal Energy (지열을 이용한 온실용 냉난방시스템 개발)

  • Lee Yong-Beom;Cho Seong-In;Lee Jae-Han;Kim Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF