• 제목/요약/키워드: Compression Paddle

검색결과 9건 처리시간 0.021초

압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안 (Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.455-460
    • /
    • 2019
  • This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

비만환자의 위장조영술에 있어 복와위 압박법의 적용에 관한 연구 (A study on the Application of Prone Compression Study for Obese Patients in Upper Gastrointestinal Series)

  • 손순룡;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.9-15
    • /
    • 1999
  • The aim of this study is to measure the application of prone compression study using compression paddle for obese patients in upper gastrointestinal series. Prone compression study using compression paddle was performed in fifty patients, who were not examined completely erect compression study for obesity. The radiographs of stomach were classified into the lower, middle, and high body and then we gave five points included 'very poor', 'poor', 'suspicious', 'good', and 'complete' according to level of detection for area gastrica and mucosal fold. Statistic analysis was performed using T-test and ANOVA, and confidence rate was fixed in 95%(P<0.05) for the significance. The results were as follows : 1. The compression marks on high body was 'poor' grades in erect and prone compression study. The points were 1.64 and 1.86, respectively. 2. The compression marks on middle body was 1.68 in erect compression study, and 'suspicious' in prone compression study. 3. The compression marks on lower body was 'poor' in erect compression study, and 'good' in prone compression study. 4. There was a high statistic signification between the two study on middle and lower body except for high body(P<0.01). 5. The average abdominal thickness of subjects was 23.98 centimeter. There was no statistic signification between the difference of average marks by the abdominal thickness(P>0.05). As these results, the prone compression study in upper gastrointestinal serie seem to be an useful study for obese patients, because it decreases pain and the feeling of uneasiness, and improve compression efficiency remarkably.

  • PDF

유방촬영장치의 압박대 재질을 고려한 투과선량 평가 (Evaluation of Radiolucent Considering the Compression Paddle Materials in Mammography)

  • 홍동희
    • 한국콘텐츠학회논문지
    • /
    • 제15권11호
    • /
    • pp.307-312
    • /
    • 2015
  • 유방촬영은 날로 증가추세에 있으며 압박을 통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기 위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질 중 비결정성 플라스틱에 대한 방사선투과성에 대해 비교해 보았다. 결과 방사선투과성 및 반가층, 투과 선량의 Pixel값이 HIPS, GPPS, ABS, Tritan, PC, PMMA 순으로 높은 결과를 보였다.

유방촬영장치에서 압박대 재질에 관한 연구 (A Study on the Compression paddle of meterials in Mammography)

  • 홍동희;정홍량
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2015년도 춘계 종합학술대회 논문집
    • /
    • pp.187-188
    • /
    • 2015
  • 유방촬영은 날로 증가추세에 있으며 압박을통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질 중 비결정 플라스틱에 대한 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

유방촬영장치에서 압박대 재료에 따른 피폭선량 평가 (The Evaluation of Radiation Dose by Compression paddle meterials in Mammography)

  • 홍동희;정홍량
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2014년도 추계 종합학술대회 논문집
    • /
    • pp.183-184
    • /
    • 2014
  • 유방촬영은 날로 증가추세에 있으며 압박을 통해 영상을 얻는 것이 화질을 향상시키고 피폭선량을 줄이는데 필수적이다. 그러나 압박대 자체의 두께로 인해 산란선과 피폭선량을 증가시킬 수 있으므로 압박대 재질에 대한 고찰이 필요하다. 현재 임상에서 쓰이고 있는 재질은 폴리카보네이트이며 플라스틱 계열이다. 환자의 피폭선량을 줄이기 위해 노력한다면 이보다 더 좋은 재질에 대해 고려해볼 필요가 있기에 본 연구에서는 플라스틱 계열 물질과 탄소계열의 카본의 방사선투과성에 대해 비교해 보고자 한다.

  • PDF

니페디핀 서방성 정제의 제제설계 (Formulation of sustained-release matrix tablets of nifedipine)

  • 최옥;김승수;박은석;지상철
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권2호
    • /
    • pp.95-101
    • /
    • 2002
  • Matrix tablets of nifedipine (NP) were prepared with Eudragit, diluent (lactose or Ca. phosphate) and Mg. stearate employing two different preparation methods (wet granulation and direct compression) to develop its sustained-release dosage forms. The effects of various formulation factors on the dissolution rate of the drug were investigated. Dissolution test was studied in pH 6.8 phosphate buffer containing 1% sodium lauryl sulfate using the paddle method. Formulation factors were the type and content of Eudragit, the type of diluent and the tablet preparation method. The optimum formula of NP matrix tablet, which resulted in a similar dissolution profile to that from Adalat Oros used as a reference, was 30 mg NP, 10% Eudragit RS, 2% Mg. stearate and an adequate quantity of lactose to yield 500 mg weight using the wet granulation method.

유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가 (Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.229-235
    • /
    • 2015
  • 유방확대수술이 미용을 위한 성형뿐만 아니라 유방암 절제술 후 재건의 목적으로 받는 등의 증가 추세이다. 유방확대수술을 받은 여성은 유방에 삽입한 보형물이 유방실질을 가려 유방질환을 진단하기 어려운 경우가 점점 증가하고 있고, 압박대로인한 보형물 파열 우려로 환자의 두려움은 증가하고 있다. 그러므로 유방보형물 삽입 여성에게 적용 가능한 압박대를 개발하여 그 유용성을 알아보고자 하며, 기존의 압박대와 새롭게 개발한 압박대를 유방보형물 삽입 환자모형의 phantom에 적용시켜 영상을 얻은 후 유방의 Inner, Outer 부분과 유두후방길이(Posterior Nipple Line; PNL), 전체적인 포함면적을 비교하여 그 유용성을 비교해보고자 한다. 개발한 압박대로 압박 시 전체 면적은 CC view에서 $9,813.797mm^2$로 10.09% 증가하였고, CC-ID view에서 $7,621.531mm^2$로 3.88% 증가하였으며, PNL은 CC view에서 90.916mm로 3.41% 증가, CC-ID view에서 75.357mm로 1.64% 증가하였다. 또한 흉벽 측 유방조직은 CC view에서 177.725mm로 3.53% 증가하였고, CC-ID view에서 152.510mm로 6.57% 증가되는 것으로 나타났으며, 기존의 압박대에 비해 개발한 압박대의 CC-ID 영상에서는 보형물이 완전히 제거된 것을 확인할 수 있었다.

유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구 (A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon)

  • 홍동희;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.81-87
    • /
    • 2015
  • 유방의 피폭선량을 줄이기 위해 압박대의 재질을 연구하였으며, 재질로는 PC, PMMA, Carbon을 이용한 방사선 투과성 및 선질 등을 측정하였고, 영상을 통한 화질도 분석하여 다음과 같은 결론을 얻었다. Unfors Xi dosimetry 사용 시 방사선 투과율은 압박대를 제거 후 측정한 결과 8.353 mGy가 나왔으며, PC 6.308 mGy, PMMA 6.223 mGy, Carbon 7.218 mGy가 측정되었다. 반가층은 PC 0.375mmAl, PMMA 0.370mmAl, Carbon 0.360mmAl으로 Carbon, PC, PMMA 순으로 높은 선질과 투과도를 보였다. InLight/OSL NanoDotTM dosimeters 사용 시 압박대를 제거 후 선량계를 위치시켜 측정한 결과 중심부위에서 1.143 mGy, 가장자리에서 12.56 mGy, PC 중심부위에서 8.990 mGy, 가장자리에서 10.291 mGy, PMMA 중심부위에서 8.391 mGy, 가장자리에서 9.654 mGy, Carbon 중심부위에서 9.581 mGy, 가장자리에서 11.313 mGy가 측정되어 Carbon, PC, PMMA 순으로 높은 투과도를 보였다. Image J에서 Pixel 평균값은 압박대를 제거한 후 976.655, PC 831.032, PMMA 819.069, Carbon 897.118로 Carbon, PC, PMMA순으로 높게 측정되었다.

비페닐 디메칠 디카르복실레이트 고체분산체 정제 처방의 최적화 (Formulation Optimization of the Tablet Prepared with Solid Dispersion of Biphenyl Dimethyl Dicarboxylate with Poloxamer)

  • 이장원;박은석;지상철
    • Journal of Pharmaceutical Investigation
    • /
    • 제28권4호
    • /
    • pp.267-274
    • /
    • 1998
  • Biphenyl dimethyl dicarboxylate (DDB) has been used for the treatment of acute and chronic hepatitis. However, its poor solubility in water, $2.5\;{\mu}g/ml$, caused low bioavailability of the drug after its oral administration. In order to increase the dissolution of DDB in gastrointestinal tracts, consequently to increase the bioavailability of the drug, DDB tablet was prepared with solid dispersion of DDB with poloxamer 338 or 407 using a direct compression method. To improve the flowability of the solid dispersion, Aerosil was used as an adsorbent. The effect of formulation variables (poloxamer and Aerosil contents) on the dissolution rate of DDB from tablets was investigated using an analysis of variance. The dissolution rate of DDB from tablets was evaluated with KP II (paddle) method. The dissolution patterns of the drug from the tablet prepared with poloxamer 407 were affected significantly by the contents of poloxamers and Aerosil over the range employed, but those of the drug from the tablet prepared with poloxamer 338 were not. The optimum formulation of the DDB tablet, showed the same dissolution pattern as that of the reference, was obtained after polynomial equations of drug dissolution profiles for each formula were fitted to contour plots. The optimum formulation ratios of DDB:poloxamer 407:Aerosil were 1:2.5:2.5 and 1:5:5.

  • PDF