• 제목/요약/키워드: Compressed hydrogen gas

검색결과 58건 처리시간 0.025초

수소 연료전지 차량용 고전압 케이블의 전자파 특성 수치해석에 관한 연구 (Numerical Analysis of Electromagnetic Characteristic of High Voltage/Current Cable for Fuel Cell Electric Vehicle (FCEV))

  • 이순용;최재훈
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.149-157
    • /
    • 2010
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) is essential. BOP systems are used many not only for motors in water pump, air blower, and hydrogen recycling pump but also inverters for these motors. Since these systems or components are connected by high voltage cables, EMC (Electromagnetic compatibility) analysis for high voltage/current cable is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields of high current/voltage cable for FCEVs is studied. From numerical analysis results, time harmonic magnetic field strength of high current/voltage cable have difference of 20~28 dB according to phase. EMI result considered ground effect of FECV at 10 m shows difference of 14.5 dB at 30 MHz and 2.8 dB at 230 MHz compared with general cable.

Heat transfer performance of a helical heat exchanger depending on coil distance and flow guide for supercritical cryo-compressed hydrogen

  • Cha, Hojun;Choi, Youngjun;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.62-67
    • /
    • 2022
  • Liquid hydrogen (LH2) has a higher density than gaseous hydrogen, so it has high transport efficiency and can be stored at relatively low pressure. In order to use efficient bulk hydrogen in the industry, research for the LH2 supply system is needed. In the high-pressure hydrogen station based on LH2 currently being developed in Korea, a heat exchanger is used to heat up supercritical hydrogen at 700 bar and 60 K, which is pressurized by a cryogenic high-pressure pump, to gas hydrogen at 700 bar and 300 K. Accordingly, the heat exchanger used in the hydrogen station should consider the design of high-pressure tubes, miniaturization, and freezing prevention. A helical heat exchanger generates secondary flow due to the curvature characteristics of a curved tube and can be miniaturized compared to a straight one on the same heat transfer length. This paper evaluates the heat transfer performance through parametric study on the distance between coils, guide effect, and anti-icing design of helical heat exchanger. The helical heat exchanger has better heat transfer performance than the straight tube exchanger due to the influence of the secondary flow. When the distance between the coils is uniform, the heat transfer is enhanced. The guide between coils increases the heat transfer performance by increasing the heat transfer length of the shell side fluid. The freezing is observed around the inlet of distribution tube wall, and to solve this problem, an anti-icing structure and a modified operating condition are suggested.

압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석 (Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process)

  • 서효민;박병흥
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.123-133
    • /
    • 2023
  • 상용 수소연료전지 차량은 기체 수소를 고압으로 압축하여 차량 내 저장 탱크로 저장하는 방식으로 충전이 진행된다. 이러한 압축 과정은 기체의 온도 상승을 유발하며, 저장 탱크의 안전성을 확보하기 위해 온도는 제한된다. 따라서 이러한 온도 상승을 설명하기 위한 열전달 모델이 필요하다. 열전달 모델은 대류 열전달 현상을 포함하며 정확한 대류 열전달 계수 추산이 요구된다. 본 연구에서는 수소 충전 과정에서의 대류 열전달 계수를 물리적 현상을 고려한 다양한 상관관계식을 이용하여 계산하고 비교 분석하였다. 수소 충전 과정은 디스펜서로부터 탱크 입구까지의 충전라인과 차량 내 저장 탱크로 분류하였고, 각각의 내부 및 외부에서의 대류 열전달 계수를 질량 유량, 직경, 온도와 압력 등 공정 변수에 따라 추산하였다. 그 결과, 충전라인 내부의 경우 저장 탱크 내부에서보다 대류 열전달 계수가 약 1000배 크게 나타났고, 충전라인 외부의 경우 저장 탱크 외부에서보다 대류 열전달 계수가 약 3배 크게 나타났다. 마지막으로 각 과정에서의 대류 열전달 계수를 종합 분석한 결과 전체 수소 충전 과정에서 저장 탱크 외부에서의 열전달 계수가 가장 낮아 열전달 현상을 지배하는 것으로 나타났다.

HCNG 엔진의 공기과잉율 변화에 따른 노킹 특성에 관한 연구 (A Study on the Knocking Characteristics with Various Excess Air Ratio in a HCNG Engine)

  • 임기훈;박철웅;이성원;최영;김창기;이장희
    • 한국가스학회지
    • /
    • 제17권1호
    • /
    • pp.7-12
    • /
    • 2013
  • 자동차 배기가스 규제가 강화됨에 따라 천연가스에 수소를 첨가하는 수소-천연가스 혼합연료(HCNG)를 기존의 압축천연가스(CNG) 엔진에 적용하려는 많은 연구들이 진행되고 있다. 그러나 수소의 높은 연소 속도로 인한 역화, 조기착화, 노킹(knocking) 등의 이상연소 발생 가능성은 엔진의 가열 또는 열효율 및 출력의 저하를 야기하는 문제점이 발생할 수 있다. 본 연구에서는 CNG 연료에 수소를 일정 부분 혼합한 HCNG 연료를 기존의 CNG 엔진에 적용하여 희박연소 한계 확장을 통해 연소 성능 개선을 확인하고, CNG와 HCNG 연료의 노킹 특성을 파악하고자 하였다. 공기과잉율의 변화에 따른 노킹 발생 조건을 관찰함으로써 HCNG 연료의 적용성 및 노킹마진을 평가하고자 하였다. HCNG 연료 사용 시 최적운전조건에서 노킹 문제없이 엔진을 운전할 수 있었으나 노킹이 일어날 수 있는 가능성이 높아져 이에 대한 대비가 필요할 것으로 판단된다.

몇 가지 냉매를 사용한 이산화탄소 액화에 대한 비교 연구 (Comparative Research on the Carbon Dioxide Liquefaction Using Several Refrigerants)

  • 박일수;황필성;정기철;안준수;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.226-233
    • /
    • 2023
  • In this study, we compared the performance of several refrigeration cycles using different refrigerants and utilizing the cold heat of liquefied natural gas (LNG) for the liquefaction of carbon dioxide. The final conditions for the liquefied CO2 were set to -20℃ and 20 bar. The refrigerants used included R404a, ammonia, propane, and propylene using a vapor recompression refrigeration cycle. For the refrigeration cycle, the CO2 at room temperature and pressure was compressed in a two-stage compression process with an intermediate cooling stage using a refrigeration unit. To compare with the liquefaction process using refrigeration, we compressed the CO2 to 8 bar in a single compression stage and cooled it to around -50℃ using the cold heat of the LNG before liquefying it. Results showed that using ammonia as the refrigerant required the least amount of compressor power for the liquefaction process, and the heat transfer area of the evaporator was the smallest when using propylene as the refrigerant. Using the cold heat of LNG instead of refrigeration using R404a resulted in approximately 69% less energy consumption.

수소 Joule-Thomson냉동기의 성능실험 (Performance test of Joule-Thomson cryocooler with $H_2$gas)

  • 백종훈;강병하;홍성제;장호명
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.457-463
    • /
    • 1999
  • The Joule-Thomson cryocooler with $H_2$gas has been developed. Cool-down characteristics and the cooling performance of a JT cryocooler have been investigated in detail. The JT cryocooler consists of JT expansion valve, heat exchanger, expansion chamber, compressed $H_2$gas storage tank, $LN_2$precooler, heater and a cryostat. The precooling process using both $GN_2$and $LN_2$was peformed to cool down the inside components of cryocooler under the maximum inversion temperature of $H_2$. The $H_2$expansion experiments have been peformed for 2-5MPa of H$_2$pressure to evaluate steady state temperatures of the cryocooler. It is found that the steady state temperatures are decreased as the H$_2$pressures are increased. The effects of cooling temperatures on the performance have been evaluated for various $H_2$and $N_2$pressures. It is seen that the cooling loads are increased, as the cooling temperature and operating pressure are increased.

  • PDF

저비용 우주 발사체 개발 동향 및 이를 위한 차세대 연료에 대한 고찰 (Development Trend of Low Cost Space Launch Vehicle and Consideration of Next Generation Fuel)

  • 배진현;구자예;윤영빈
    • 한국항공우주학회지
    • /
    • 제45권10호
    • /
    • pp.855-862
    • /
    • 2017
  • 인공위성의 경량화 및 소형화로 인하여 대형발사체보다는 발사 비용이 저렴한 저비용 발사체에 대한 관심이 증가되고 있다. 저비용 발사체의 비용 절감 중 가장 대표적인 방식이 발사체의 재사용이다. 저비용 발사체를 개발하고 있는 대부분의 기업들 역시 발사체 재사용 방식을 채택하고 있다. 이러한 재사용 목적과 더불어 친환경 우주 발사체에 대한 요구가 증가되면서 저비용 발사체에 사용되는 연료의 선택 역시 매우 중요해졌다. 친환경적이면서 발사체의 재사용이 가능하게 하는 연료 중 에너지 밀도 등 다른 요인을 고려했을 때 가장 적합한 것이 메탄이며, 메탄에 수소를 첨가하여 에너지 밀도를 높게 만든 HCNG(hydrogen-enriched compressed natural gas) 역시 적합하다고 판단되었다. 본 연구는 한국형 발사체 개발 이후 국내 우주 개발 방향 설정의 참고자료로써 전 세계 저비용 발사체 동향 및 로켓 연료의 특성에 대해 고찰하였다.

대용량 액체 수소 저장탱크를 위한 다층단열재의 단열성능 분석 (Adiabatic Performance of Layered Insulating Materials for Bulk LH2 Storage Tanks)

  • 김경호;신동환;김용찬;강상우
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.642-650
    • /
    • 2016
  • One of the most feasible solution for reducing the excessive energy consumption and carbon dioxide emission is usage of more efficient fuel such as hydrogen. As is well known, there are three viable technologies for storing hydrogen fuel: compressed gas, metal hydride absorption, and cryogenic liquid. In these technologies, the storage for liquid hydrogen has better energy density by weight than other storage methods. However, the cryogenic liquid storage has a significant disadvantage of boiling losses. That is, high performance of thermal insulation systems must be studied for reducing the boiling losses. This paper presents an experimental study on the effective thermal conductivities of the composite layered insulation with aerogel blankets($Cryogel^{(R)}$ Z and $Pyrogel^{(R)}$ XT-E) and Multi-layer insulation(MLI). The aerogel blankets are known as high porous materials and the good insulators within a soft vacuum range($10^{-3}{\sim}1$ Torr). Also, MLI is known as the best insulator within a high vacuum range(<$10^{-6}{\sim}10^{-3}$ Torr). A vertical axial cryogenic experimental apparatus was designed to investigate the thermal performance of the composite layered insulators under cryogenic conditions as well as consist of a cold mass tank, a heat absorber, annular vacuum space, and an insulators space. The composite insulators were laminated in the insulator space that height was 50 mm. In this study, the effective thermal conductivities of the materials were evaluated by measuring boil-off rate of liquid nitrogen and liquid argon in the cold mass tank.

차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발 (Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

수소 연료전지 차량용 고전압 케이블과 일반 케이블에 의한 차량 전자파 방사 특성 수치해석 연구 (Numerical Analysis of Electromagnetic Radiation Characteristics by High Voltage and General Cables for Fuel Cell Electric Vehicle (FCEV))

  • 이순용;서원범;임지선;최재훈
    • 한국수소및신에너지학회논문집
    • /
    • 제22권2호
    • /
    • pp.152-160
    • /
    • 2011
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) which is consisted of many motors in water pump, air blower, and hydrogen recycling pump as well as inverters for these motors is essential. Furthermore, there are also electric systems for entertainment, information, and vehicle control such as navigation, broadcasting, vehicle dynamic control systems, and so on. Since these systems are connected by high voltage or general cables, EMC (Electromagnetic compatibility) analysis for high voltage and general cable of FCEV is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields by high voltage and general cables for FCEVs is studied. From numerical analysis results, total time harmonic electromagnetic field strength from high voltage and general cables have difference of 13~16 dB due to ground effect by impedance matching. The EMI results of FECV at 10 m distance shows difference of 41 dB at 30 MHz and 54 dB at 230 MHz compared with only general cable routing.