• Title/Summary/Keyword: Composite resins

Search Result 447, Processing Time 0.031 seconds

A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME (수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구)

  • Kim, Kyung-Hyun;Kwon, Oh-Sung;Kim, Hyun-Gee;Baek, Kyu-Chul;Um, Chung-Moon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

A STUDY ON PHYSICAL PROPERTIES OF FLOWABLE COMPOSITE RESINS (유동성 복합레진의 물리적 성질에 대한 연구)

  • Kim, Ji-Young;Jeong, Byung-Cho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.423-429
    • /
    • 2002
  • Recently, the clinical uses of flowable composite resins have increased because of fast, convenient and excellent accessibility, but little has been reported about physical properties of flowable resins. The purpose of this study was to measure and compare the physical properties(compressive strength, relative flowability, relative radiopacity) of 4 contemporary flowable composite resins(Filtek flow, Tetric Flow, Revolution Palfique Estelite LV high flow). The results were as follows; 1. There were no significant differences between 4 flowable composite resins in compressive strength, but all were lower than that of traditional hybrid composite resin(p<0.001). 2. The relative flowability were increased in order of Palfique Estelite LV high flow, Revolution, Filtek flow, Tetric Flow and sealant(p<0.001), but there were no significant differences between Filtek flow and Tetric Flow. 3. There were significant differences between flowable composite resins in relative radiopacity and they showed similar or higher radiopacity than dentin(p<0.001), especially Tetric Flow and Filtek Flow showed higher radiopacity than enamel(p<0.001). This results suggested that the stress of application area have to be considered since flowable composite resins have lower compressive strength than hybrid composite, and the differences of flowability between these flowable composite resins can be considered when they are selected. All tested flowable composite resins showed optimal radiopacity to ISO's recommend.

  • PDF

Microleakage of posterior packable composite resin at the gingival margins of class II cavities

  • Choi, Su-Jin;Kwon, Hyuk-Choon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.585.1-585
    • /
    • 2001
  • The use of flowable composite resins as liners in class II packable composite resins has been suggested by some manufacturers. However, the contributions of this technique are unproven. Objectives: The aim of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners.. Method: Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each.(중략)

  • PDF

A Study on the fracture strength of 4 Kinds of Direct Composite Resins (4종의 direct composite resin의 파절강도 비교)

  • Kim, Nam-Joong
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.87-92
    • /
    • 2019
  • Purpose: The Purpose of this study is to compare the fracture strength of 4 kinds of direct composite resins. Methods: his study performed experiments on the fracture strength of direct composite resins after polymerizing 4 kinds of direct composite resins on the MOD cavity standard specimens. Results: The fracture strength of Aelite(Bisco) was the highest at 176.26N(p<0.05). According to post-hoc study with Turkey honest significant difference by multiple comparison on fracture strength test results, there were statistically significant differences between all kinds of direct composite resin. But the statistical difference between Z350(3M) and Spectrum(DP) was not significant. Conclusion: Aelite(Bisco) scored the highest concerning the fracture strength.

Flexural strength of indirect composite resin with different polymerization conditions (중합 조건에 따른 간접복합레진의 굴곡강도)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the flexural strength of indirect composite resins with different polymerization conditions. Methods: Ten specimens ($2mm{\times}2mm{\times}25mm$) of each composite resins (Tescera (T), Gradia (S) and Sinfony (S)) were fabricated by two polymerization methods : manufacturers's and light heat pressure. Composite resins polymerized by manufacturers's method and light heat pressure served as control (TS, GS and SS) and experimental groups (TE, GE and SE), respectively. The composite resins were tested for flexural strength and the surface of composite resins were observed with scanning electron microscope (SEM) under X1,000 magnification. Results: The flexural strength values of cured composite resin decreased in the following order: TE (195.4MPa), TS (179.8MPa), GE (169.9MPa), SE (137.7MPa), SS (111.1MPa) and GS (100.9MPa) groups. Conclusion: The flexural strength values between the control and the experimental groups were not significantly different although experimental groups showed higher flexural strength values than control groups.

IN VITRO MICRO-SHEAR BOND STRENGTH OF FIVE COMPOSITE RESINS TO DENTIN WITH FIVE DIFFERENT DENTIN ADHESIVES (미세-전단 결합 강도 시험을 이용한 상아질 접착제와 수복용 복합 레진의 호환성에 관한 연구)

  • Chung, Jin-Ho;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.353-364
    • /
    • 2004
  • The purpose of this study was to compare and to evaluate the combination use of 5 kinds of dentin adhesive systems and 5 kinds of composite resins using micro-shear bond test. Five adhesive systems (Prime & Bond NT (PBN). Onecoat bond (OC), Excite (EX), Syntac (SY), Clearfil SE bond (CS)) and five composite resins (Spectrum (SP), Synergy Compact (SC), Tetric Ceram (TC), Clearfil AP-X (CA), Z100 (Z1)) were used for this study ($5{\;}{\times}{\;}5{\;}={\;}25group$, n =14/group). The slices of horizontally sectioned human tooth were bonded with each bonding system and each composite resin, and tested by a micro-shear bond strength test. These results were analyzed statistically. The mean micro-shear bond strength of dentin adhesive systems were in order of CS (22.642 MPa), SY (18.368 MPa), EX (14.599 MPa). OC (13.702 MPa). PBN (12.762 MPa). The mean bond strength of self-etching primer system group (CS, SY) in dentin was higher than that of self-priming adhesive system groups (PBN, EX, OC) significantly (P<0.05). The mean bond strength of composite resins was in order of SP (19.008 MPa), CA (17.532 MPa). SC (15.787 MPa), TC (15.068 MPa). Z1 (14.678 MPa). Micro-shear bond strength of SP was stronger than those of other composite resins significantly (P < 0.05). And those of TC and Z1 were weaker than other composite resins significantly (P < 0.05). No difference was found in micro-shear bond strength of composite resin in self-etching primer adhesive system groups (CS, SY) statistically. However, there was significant difference of micro-shear bond strength of composite resin groups in self-priming adhesive systems group (PBN, EX, OC). The combination of composite resin and dentin adhesive system recommended by manufacturer did not represent positive correlation. It didn't seem to be a significant factor.

A STUDY ON SURFACE HARDNESS OF COMPOSITE RESINS ACCORDING TO STORAGE CONDITON AND HEAT TREATMENT (보관조건과 열처리에 따른 복합레진의 표면경도에 관한 연구)

  • Kang, Seung-Hoon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.194-204
    • /
    • 1994
  • The purpose of this study was to evaluate the surface hardness of composite resins according to heat treatment. storage condition and storage time. In this study. two kinds of composite resin inlays and one kind of conventional posterior composite resin were used as experimental materials. One hundred eighty composite resin specimens were constructed from composite resin inlays and conventional posterior composite resin. The conditions of this study were heat treatment. storage condition and storage time. Hardness readings were taken from the top surface of each samples using the Vickers microhardness tester(MHT-l. Matsuzawa. Japan}. The following results from this study were obtained: 1. Regardless of storage condition. both composite resin inlay and conventional posterior composite resin have a higher surface hardness under heat treatment than not. 2. Composite resins with heat treatment have a higher surface hardness under dry storage than under water immersion. 3. In case of Clearfil Photo Posterior and Brilliant Enamel with heat treatment. there was no significant difference with time. but Clearfil CR Inlay with heat treatment. there was statistical difference after 24 hours. 4. Surface hardness of composite resins with coarse hybrid type was higher than that of composite resin with fine hybrid type.

  • PDF

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

Tribological Evaluation of Dental Composite Resins Containing Prepolymerized Particle Fillers

  • Ren, Jing-Ri;Kim, Kyo-Han;Kim, Seock-Sam
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.727-734
    • /
    • 2001
  • The Tribological evaluation of commercial dental composite resins containing prepolymerized particle fillers was investigated. Composite resins such as Metafil, Silux Plus, Heliomolar, and Palfique Estelite were selected as specimens. In the wear tests, a ball-on-flat wear test method was used. The friction coefficient of Metafil was quite high. The wear resistance of Silux Plus and Palfique Estelite was better than that of Metafil and Heliomolar under the same experimental conditions. The main wear mechanism of the composite resins containing prepolymerized particle fillers was abrasive wear caused by the brittle fracture of the prepolymerized particles and the debonding of the filler and the matrix.

  • PDF

THE COLOR STABILITY OF PORCELAIN REPAIR COMPOSITE RESINS (도재 수복용 복합레진의 색 안정성에 관한 연구)

  • Shin Mee-Ran;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.171-179
    • /
    • 1991
  • The purpose of this study was to investigate the color stability of 3 porcelain repair composite resins Twenty specimens of each composite resin were made and ten specimens were polished at 10 minutes after polymerization, and the others were polished at 48 hours after polymerization. For 60 days, the color characteristics were measured by fiber-optic colorimeter (Model Tc-6FX, Tokyo Denshoku Co.). The obtained results were as follows: 1. The changes of $a^*$ value and $b^*$ value in composite resin polished at 10min. after polymerization were greater than those of composite resins polished at 48 hrs. after polymerization. 2. The $a^*$ values of all composite resins were increased and the $b^*$ values were decreased. 3. The $L^*$ values were decreased in composite resin manufactured by K & B Co., which were polished at 10min. after polymerization, but increased in composite resin manufactured by K & M Co., polished at 48 hrs. after polymerization.

  • PDF