• 제목/요약/키워드: Composite resin crown

검색결과 98건 처리시간 0.02초

치과 치료학에서 적용되는 접합기술 연구 ; 스테인리스강 크라운에 접합된 직접용 콤포짓트 레진과 간접용 콤포짓트 레진의 전단결합강도 비교 (Comparison Study for the Shear Strength of the Bondings between Stainless Steel Crown/Direct Type Composite Resin and Stainless Steel Crown/Indirect Type Composite Resin)

  • 김광수;백광우
    • Journal of Welding and Joining
    • /
    • 제29권4호
    • /
    • pp.93-99
    • /
    • 2011
  • This study was performed to compare the shear strength of the bondings between stainless steel crown/direct type composite resin and stainless steel crown/indirect type composite resin. Four groups of bonding conditions were prepared. Two groups of bonding conditions were made by the indirect type composite resin system and the other two groups were made by the direct type composite resin system. The shear strength tests were carried out using universal testing machine, Model 4465 of Instron Co.. It was indicated that the bond strength values of the indirect type composite resins were higher than those of the direct type composite resins. TE-SE group was superior to the TE-ONE in indirect type resin system. These results were thought to be the high degree of the polymerization accompanied with temperature and pressure of the resin of indirect type resin. It was also found that indirect composite resin contains less amount of porosity in resin.

Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향 (THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT)

  • 하점임;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF

보철물 변연의 위치가 abfraction된 치아의 응력 분포에 미치는 영향에 대한 유한요소법적 분석 (Effect of the marginal position of prosthesis on stress distribution of teeth with abfraction lesion using finite element analysis)

  • 김명현;이청희
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.202-210
    • /
    • 2014
  • 목적: 이 연구의 목적은 abfraction병소가 있는 금속도재관수복 치아를 수복하거나 하지 않을 때 나타나는 응력집중과 분포를 유한요소분석으로 평가하는 것이다. 재료 및 방법: 상악 제1 소구치를 선정하여 총 10개의 유한요소모델을 만들었다. 모델 1은 자연치; 모델 2는 협측과구개측 백악법랑경계 상방 2 mm에 변연이 위치한 금속도재관; 모델 3은 협측과구개측 백악법랑경계에 변연이 위치한 금속도재관; 모델 4는 abfraction병소를 가진 자연치; 모델 5와 6은 다른 조건은 각각 모델 2와 3과 동일하면서 abfraction병소를 가진 치아; 모델 7은 abfraction병소를 가지고 composite resin으로 수복된 자연치;모델 8과 9는 각각 모델 5와 6과 동일한 모델에 abfraction병소를 composite resin으로 수복한 후 금속도재관 장착한 치아; 모델 10은 composite resin으로 abfraction lesion을 수복하고 금속도재관의변연을 abfraction병소보다 하방에 위치시킨 치아였다. 위치를 서로 달리한 하중 load A와 load B를 가하여, 각 기준점에서의 von Mises stress값들을 측정하여 비교하였다. 결과: Abfraction병소가 있는 치아에 load A 또는 load B를 주었을 때, 응력은 lesion의 apex에 집중되었다. 반면, abfraction병소를 composite resin으로 충전한 치아에 load A 또는 load B를 주었을 때 응력값은 apex에서 감소하였다. 결론: Abfraction이 있는 치아는 복합 레진으로 수복해주는 것이 응력의 집중을 줄여서 병소의 예후에 유리한 것으로 나타났으며, Abfraction이 발생된 치아를 금속 도재관으로 수복할 경우 협측변연을 법랑질 상에 위치시키는 것이 유리하였다.

Brånemark 골유착성 매식체의 금관 수복재료에 따른 지지조직의 응력분석 (The stress analysis of supporting tissues according to crown restorative materials in Brånemark osseointegrated implant)

  • 정관호;배태성;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.199-215
    • /
    • 1990
  • This study was to analyze the stress distribution of implant and supporting tissue in $Br{\aa}nemark$ osseointegration implant. The analysis has been conducted by using the axisymmetric finite element method and type of model according to crown material. Tests have been performed at 1 kg load on central fossa of crown portion. Each type of model was designed differently according to crown material. 1) Porcelain fused to metal crown(Model A) 2) Composite resin veneered crown(Model B) 3) Acrylic resin veneered crown(Model C) 4) Type III gold crown(Model D) The displacements and stresses of implant and supporting structures were analyzed to investigate the influence of the type of crown material. The results were obtained as follows : 1. Displacement of implant was shown uniformly downward displacement in all models and abutments were observed distally downward displacement. 2. In supporting tissues, stress was concentrated on the crest of compact bone and the spongy bone below implant. 3. The PFM and the type III gold crown showed the largest concentration of stress at the crest of compact bone and the spongy bone below implant, respectively. Acrylic resin artificial teeth and composite resin veneered crown indicated almost the same distribution of stress. 4. The gold screw, the abutment screw and the top of abutment showed the concentration of stress in implants of every model.

  • PDF

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

수평 포스트와 이중중합 복합레진으로 수복된 치관-치근 복합파절 치아의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF CROWN-ROOT FRACTURED TEETH REPAIRED WITH DUAL-CURED COMPOSITE RESIN AND HORIZONTAL POSTS)

  • 장석우;이용근;경승현;유현미;오태석;박동성
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.383-389
    • /
    • 2009
  • 이 연구의 목적은 이중 중합복합레진과 수평 포스트를 이용하여 수복한 치관-치근 복합파절 치아의 수직파절 저항성을 알아보기 위한 것이다. 48개의 발치된 사람의 소구치에 실험적으로 치관-치근 복합파절을 일으킨 후 대조군 및 3개의 실험군에 (n=12) 각각 할당하였다. 대조군에서는 치아 파절편을 레진시멘트를 이용하여 접착한 후 근관치료를 시행하고, 근관와동을 이중중합 복합레진을 사용하여 충전하였다. 실험군에서는, 각각의 치아에 근관치료를 시행한 후 레진-포스트 군에서는 근관와동을 수평 포스트 및 이중중합 복합레진을사용하여 충전하였다. 레진 군에서는 근관와동을 포스트 없이 이중중합 복합레진만 사용하여 수복하였으며 아말감 코어 군에서는 근관와동을 접착 아말감을 사용하여 수복하였다. 이렇게 수복된 치아를 처음과 같은 방법으로 다시 치관-치근 복합파절을 유도하여 이때의 파절 저항성을 기록하고 이 값과 처음 파절을 유도하였을 때의 파절 저항성의 비를 계산하고 각 군별로 차이가 있는 지 검증하기 위해 Kruskal-Wallis test를 시행하였다. 수복된 치아의 파절저항성은 레진-포스트군, 대조군, 레진군, 접착 아말감 순으로 높았으며, 이 실험결과로 볼 때,치관-치근 복합파절 치아의 수복 시 수평 포스트를 사용하는 것이 재파절 방지를 위해 효과적 일 것으로 사료된다.

유동성 복합레진을 이용한 유구치 II급 수복의 생존율 (Survival Rates of Class II Restoration in Primary Molar with Flowable Resin Composite)

  • 서혜준;박소영;이은경;정태성;신종현
    • 대한소아치과학회지
    • /
    • 제48권1호
    • /
    • pp.12-20
    • /
    • 2021
  • 이 연구의 목적은 소아 환자의 유구치 인접면 우식증 치료에 유동성 복합레진을 이용한 II급 와동 수복물의 생존율을 기성금속관과 비교하여 후향적으로 평가하는 것이다. 2015년 6월부터 2019년 8월까지 인접면 우식증으로 진단되어 유동성 복합레진과 기성금속관 수복 치료를 시행한 590명의 1,504개의 유구치에 대한 전자의무기록과 방사선사진을 조사하였다. 수집된 자료는 Kaplan-Meier method를 이용해 생존 분석을 하였다. 유동성 복합레진 수복된 치아의 1년 생존율은 98.5%, 3년 생존율은 87.7%, 평균 생존기간은 39개월이었으며, 기성금속관과 비교할 때 통계적으로 유의한 차이는 없었다(p = 0.896). 현 연구의 한계 내에서 유동성 복합레진을 이용한 II급 수복은 유구치 인접면 우식증 치료의 예지력 있는 선택지가 될 수 있다고 사료된다.

강화형 strip crown의 사용 (GLASS FIBER REINFORCED STRIP CROWN IN PRIMARY TEETH)

  • 김대업
    • 대한소아치과학회지
    • /
    • 제32권1호
    • /
    • pp.132-135
    • /
    • 2005
  • 본 연구의 목적은 유전치 심미수복의 새로운 방법으로 glass fiber를 이용한 강화형 strip crown의 사용을 제시하고자 하는 것이다. Strip crown의 제작을 위하여 celluloid crown form(3M, USA)과 복합레진은 Z100(P shade, 3M, USA)을, 유동성 복합레진은 Aeliteflo(Bisco Inc., USA)를 사용하였다. 상아질 결합제는 Clearfil SE Bond(Kuraray Medical Inc., Japan)를 사용하였고 강화를 위하여 그물형 glass fiber(TESCERA Fiber Mesh, Bisco Inc, USA)를 사용하였다. 적절한 크기의 celluloid crown form을 성형하여 삭제된 치아에 시적한 후 레진 접착제와 유동성 복합레진으로 처리한 그물형 glass fiber를 설측 내면에 삽입하고 광중합하였다. 잔여 공간에 복합레진을 채우고 치아에 끼운 다음 광중합하였다. 복합레진의 심미성은 유지하면서 glass fiber로부터 기계적 장점을 얻을 수 있을 것으로 사료된다. 새로운 강화형 strip crown의 물성에 대한 후속연구가 필요하다.

  • PDF

치수복조재와 최종수복재에 따른 대구치 부분치수절단술의 비교 (Comparison of Partial Pulpotomy in Permanent Molars Using Different Pulp Capping Agents and Restoration Materials)

  • 이지미;이난영;이상호;지명관
    • 대한소아치과학회지
    • /
    • 제47권2호
    • /
    • pp.148-156
    • /
    • 2020
  • 이 연구의 목적은 우식에 의해 치수가 노출된 영구대구치에서 Biodentine™(BD)과 RetroMTA®(RMTA)의 치수복조재 및 stainless steel crown(SSC)와 composite resin(CR)의 최종수복재를 적용하여 치료한 부분치수절단술 증례들의 임상 및 방사선학적 비교 평가를 통해 각 치수복조재 및 최종수복재가 치료 결과에 미치는 영향을 알아보는 것이다. 영구대구치의 상아질의 우식으로 진단되어 부분치수절단술을 받은 소아 및 청소년을 대상으로 경과관찰 기간이 1년 이상인 증례를 선정하여 임상적 평가 및 방사선학적 평가를 통해 치료의 성공률을 평가하였으며 각 성공률에 대해 Fisher's exact test로 통계 분석하였다. 치수복조재에 대한 평가에서 BD이 RMTA에 비해 더 높은 치료 성공률을 보였다(p < 0.05). 치수복조재의 종류와 관계없이 최종수복재를 평가하였을 때 SSC으로 수복했을 때 CR으로 수복한 경우에 비해 더 높은 성공률을 보였다(p < 0.05). 치수복조재로 RMTA를 사용하고 최종수복재로 CR을 사용한 경우에 가장 낮은 성공률을 보였다(p < 0.05).