• Title/Summary/Keyword: Composite insulators

Search Result 51, Processing Time 0.026 seconds

A Study on the Long-term Mechanical Properties Under Static and Cyclic State of Composite Insulators for Transmission Lines (송전용 고분자 애자의 정적 및 동적인 상태에서 장기 기계적 특성 연구)

  • Kim, S.Y.;Kim, Y.S.;Hong, J.Y.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.869-871
    • /
    • 1998
  • The extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. The actual load working on the insulator in the field is not static load but cyclic load. So in this paper, we discussed an examination of aging degradation by mechanical performance of composite insulators under static tension load and cyclic tension load. and also described useful approaches for analyzing their long term performance so as to develop reliable composite insulators. The static and cyclic tension load-time test data were examined by Weibull distribution for their capability of presuming long term performance. It was found that cyclic tension loads were more severe than static tension loads. The results also indicate that it may be relevant for an user to select composite insulators on basis of their performance under cyclic tension loads than static tension loads.

  • PDF

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

Study on Optimum Design for constitution part of Composite Insulator (Composite Insulator 구성 부품에 대한 최적 설계 연구)

  • Chung, Young-Soo;Choi, Sung-Man;Jang, Yoon-Ki;Lee, Dong-Woen;Kim, Jeong-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1181-1186
    • /
    • 2008
  • Insulators which are used in the domestic electrical industries are mostly depended on importation from some advance countries. Even though insulators which are made of ceramic material have been mostly used domestically, the ratio of usage on composite insulators is recently being increased because of difficulties in manufacturing and high cost regarding ceramic stuffs. In this research, we are trying to develop the composite insulators which are very efficient in insulation regardless of the matter of weight. Even though the technique of manufacturing composite insulator are quite generalized worldwide at the moment, one of the most important issue is to keep security on the know-how that an ingredient of insulated material named 'SF6 gas' is included. Therefore, The aim of this paper is to improve the bonding force and air tight property between two components of composite insulator, Flange and FRP Tube.

  • PDF

Evaluating methods of properties in composite insulators and necessities (Composite insulator의 특성평가 방향 및 필요성)

  • Kim, I.S.;Cho, H.G.;Kang, D.P.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1226-1228
    • /
    • 1995
  • This paper introduced foreign standard testing methods on composite insulators(for transmission, distribution) and mentioned on (1)evaluation of material property (2)short-term test of prototype (3)insulation efficiency on use to evaluation property of insulators made of composite insulating materials.

  • PDF

Status Assessment of Composite Insulators for Outdoor HV Applications

  • Gorur, R.S.
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.6-12
    • /
    • 1998
  • An attempt has been made to summarize the research and development on the topic of assessing the status of composite Insulators used for outdoor power delivery. Advances made in the evaluation of the electrical performance are discussed. The findings are applicable to other composite insultaing systems, as well. Aspects that have been understood well enough to be of practical use, and those needing further research are outlined.

  • PDF

Properties of composite insulators stuck by cement powder (고분자 애자의 시멘트 분진에 의한 특성 변화 연구)

  • Lee, Sang-Jin;Kim, Dong-Wook;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1602-1604
    • /
    • 2000
  • When insulators are operated near cement factories, some amount of cement powder may be stuck on the surface of insulators and decreases their electrical performances. Three kinds of insulators, such as, silicone EPDM and porcelain insulators, are tested in this paper. Testing Voltage of 25kV is applied to the samples, and surface leakage current is measured for 6 months after cement solvent of 10 vol% was stuck on the surface of each insulator in the laboratory. Insulation layers are cut from 3 and 6 month-aged insulators and tested for ac breakdown, impulse breakdown, contact angle. After aging, electrical properties are unchanged in silicone and EPDM insulators but show some changes in porcelain insulators.

  • PDF

A Study Performance and Design Compositor Insulator for 170kV D/S (170kV급 단로기용 Composite Insulator 설계 및 특성 연구)

  • Cho, H.G.;Park, K.H.;Han, D.H.;Yoon, M.S.;Jin, S.Y.;Song, H.S.;Lee, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.252-254
    • /
    • 2003
  • Recently composite insulators are being used for outdoor high voltage applications. Composite insulators for transmission line have significant advantages over porcelain insulators, especially for ultra-high voltage. Their advantages are light weight, vandalism resistance, and hydrophobicity. We developed a 170kV high reliable vertical break disconnector with good long term electrical and mechanical performance which was achieved by the improvement of electrical performance and light weight. We discuss the outline of the development and the product.

  • PDF

Development of 132kV XLPE Cable Composite Bushing EB-A (132kV XLPE Cable용 Composite Bushing 기중종단접속함 개발)

  • Kim, J.H.;Oh, E.J.;Kim, K.Y.;Park, J.K.;Jeoung, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.547-549
    • /
    • 2000
  • Silicone insulators have many advantages over porcelain insulators. Especially silicone insulators have good characteristics of impact hardness, surface insulation, ease of processing, mass productivity and don't have risk of bombardment and vandalism. Recently insulation part made by silicone are becoming widely used. In this paper we introduce the development of Sealing End for 132kV XLPE cable with silicone composite hollow insulator and the adoption of it to a actual transmission line in abroad. This paper contains of design procedure, structure, electrical performance of it.

  • PDF

A Study on the Mass Productive Manufacture and Quality of Composite Long Rod Insulator for the railway (전철용 고분자 장간애자에 대한 양산관점에서의 제조와 품질관리에 관한 연구)

  • 홍진영;김영성;박완기
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.436-441
    • /
    • 1998
  • We developed the composite long rod insulator for railway, and the developed insulators were applied to commercial lines, KNR through a series of preparations such as establishment of specification, diverse tests and evaluation of reliability, and improvement of manufacturing system, etc. This paper presents some considerations for mass Production of the composite insulators in view of steady quality especially. 1 believe that our tries, though it is incomplete in view of low cost, is effective in good performance of the insulators in service and these in-service experience is enough to be a basis of more progress in field of insulation technique.

  • PDF

A Study on Bonded Joints of Composite Hollow Bushing (Composite Hollow Bushing의 접합기술에 관한 연구)

  • Cho, Han-Goo;Kang, Hyung-Kyung;Yoo, Dea-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.493-494
    • /
    • 2008
  • During the last years hollow core insulators started their success story in the field of high voltage engineering for electrical apparatus, substituting porcelain insulators. The termination, also named top and bottom fittings are used for the connection to the rest of the electrical apparatus. The top and bottom flange are attached to the composite to transmit mechanical load and also ensure the gas tightness. They are bonded by epoxy glue with a glass transition temperature of about $130^{\circ}C$-$150^{\circ}C$ the glass reinforced epoxy tube of filament winding. This paper describes the results of a study on the bonded joints of fiber reinforced epoxy tube and cast aluminum. This suggests that surface roughness and glue types play an important role in evaluating of gas sealing capability on the flange and fiber reinforced epoxy tube in the composite hollow bushing.

  • PDF