• Title/Summary/Keyword: Compliance rate

Search Result 454, Processing Time 0.025 seconds

Numerical Evaluation of Dynamic Transfer Matrix and Unsteady Cavitation Characteristics of an Inducer

  • Yonezawa, Koichi;Aono, Jun;Kang, Donghyuk;Horiguchi, Hironori;Kawata, Yutaka;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.3
    • /
    • pp.126-133
    • /
    • 2012
  • The transfer matrix and unsteady cavitation characteristics, cavitation compliance and mass flow gain factor, of cavitating inducer were evaluated by CFD using commercial software. Quasi-steady values of cavitation compliance and mass flow gain factor were obtained first by using steady calculations at various flow rate and inlet cavitation number. Then unsteady calculations were made to determine the transfer matrix and the cavitation characteristics. The results are compared with experiments to show the validity of calculations.

A Study on the Dynamic Fracture Toughness of Welding Structural Steels by Instrumented Impact Testing (계장화 충격시험법에 의한 구조용강 용접부의 동적 파괴인성에 관한 연구)

  • 김헌주;김경민;윤의박
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.42-51
    • /
    • 1993
  • In this study, investigations were conducted in calculating parameters of elastic-plastic fracture mechanics using single specimen. The validity of these testing methods was judged by the confirmation of multiple specimen method of stop block test. The results were as follows: In order to measure a fracture toughness using the instrumented impact test, two general requirement must be considered; One, setting up proper impact velocity considered the effect of loading and the other, the necessity of low blow test for obtaining true energy by the compliance correction. It was possible to detect a crack initiation point by calculating the compliance changing rate from a load-defection curve. Criterion of a stable crack growth, $T_{mat}$ could be estimated by using key-curve method for a base metal. and combining Kaiser's rebound compliance with Paris-Hutchison's $T_{appl}$ equation for the brittled zone of welding heat affected.at affected.d.

  • PDF

A study on the improvement of the score system in the hazard analysis and critical control points prerequisite program for meat shops in Korea

  • Baek, Seung-Hee;Nam, Insik
    • Korean Journal of Veterinary Research
    • /
    • v.61 no.3
    • /
    • pp.20.1-20.9
    • /
    • 2021
  • This study is to develop a new scoring system for rating Hazard analysis and critical control points prerequisite evaluation items for meat shops to provide a more objective and accurate evaluation of food safety compliance. The importance of each item was measured by looking at the hazard severity level and the rate of non-compliance associated with it. It was found that the new scoring system is more stringent and gives a clearer picture of compliance with the most critical safety standards, and therefore is expected to have a positive effect on the hygiene and safety of livestock products.

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

BER Simulator Development for Link Compliance Analysis

  • Kang, Hyun-Chul;Kim, Woo-Seop;Lee, Jae-Wook;Jang, Young-Chan;Park, Hwan-Wook;Kim, Jong-Hoon;Lee, Jung-Bae;Kim, Chang-Hyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.150-155
    • /
    • 2008
  • This paper is related to developing new Bit Error Rate (BER) simulator, Sam sung BER simulator (SBERS), in order to evaluate the link compliance and all kinds of effects of link compliance in a real environment. SBERS allows to generate transmit pulse accurately by using the various parameters, and obtain the eye diagram and bathtub curve, which represents the performance of link, by calculating the transmit pulse and the measured frequency response characteristics. SBERS give results as same as real environment after taking account of distribution and value of noise. To verify the accuracy of simulator, we derive the simulated and measured result and compare eye opening. The difference came out to be within 5% error. It is possible to estimate the real environment and design the transmitter and receiver circuit effectively using new BER simulator, SBERS.

Extended Compliance Solution of ESET Specimen for Thermal fatigue Crack Growth Test (열피로 균열성장시험을 위한 ESET 시편의 확장된 컴플라이언스 해)

  • Lee, Ho-Jin;Kim, Maan-Won;Lee, Bong-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.62-67
    • /
    • 2005
  • An eccentrically-loaded single edge crack tension specimen (ESET) is similar to a compact tension(CT) specimen loaded in tension-tension. The standard ESET specimen exhibits advantages over other types of cracked specimen, such as n, single-edge crack, and middle-crack tension specimen. The details of ESET specimen configuration, test procedure, and calculations are described in ASTM E647 standard. However, a difficulty in attaching COD gage to the knife-edge on the front foe of the specimen can be found when the size of ESET specimen is small for rapid cooling and heating in thermal fatigue testing. The finite element analysis is performed for the ESET specimen with projected knife-edge on the front foe and a crack-length-compliance equation is suggested for the new specimen configuration. Calibration test are conducted with 347 stainless steel to compare the measured crack length with the calculated crack length from the suggested compliance expression. The test results showed good agreements with those of analysis.

Survey of Pharmacy Practice for Compounding Parenteral Nutrition in Hospital Setting - 2009 (병원약국 대상으로 정맥영양제 조제 실행에 관한 연구-2009)

  • Sin, Hye-Yeon;Jung, Ki-Hwa
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.244-251
    • /
    • 2010
  • Standardized parenteral nutrition is required to improve patient's safety, clinical appropriateness and to increase uniformity between institution and institutions. We assessed the consistency with the American society for parenteral and enteral nutrition (A.S.P.E.N.) practice guideline for PN by evaluating current practice process for parenteral nutrition formulation in inpatients pharmacies in Korea. Each question in this survey was based on 2007 A.S.P.E.N. recommendations of standard parenteral nutrition formulation, the American society of health-system pharmacists (ASHP), and the United State Pharmacopoeia (USP) Chapter 797 guideline for compounding parenteral nutritions. All 90 Korean society of hospital pharmacist (KSHP) member directors of pharmacy were requested to respond to the survey in order to compare the survey results to ASHP national survey of pharmacy practice in hospital settings (2002) in compliance with A.S.P.E.N. guideline. We had final response rate of 35.6%. 25 (100%) hospitals complied with this Garb guideline (response rate was 84.4%) which was the highest compliance. Only 17.9% of hospital pharmacies were actively involved in complications monitoring. Monitoring complications and efficacy were least in compliance with the A.S.P.E.N. guideline. 69.0% of Korean pharmacists adjusted medication dosage based on disease state or monitoring laboratory data in compliance with the A.S.P.E.N. guideline. Over 50% of the hospital pharmacies failed to provide and evaluate staff training in aseptic manipulation skills periodically. Korean hospital pharmacies need to comply with the standard practice guideline for compounding sterile preparation in order to provide better quality of parenteral nutrition service for specific patient population.

A comparative study for beams on elastic foundation models to analysis of mode-I delamination in DCB specimens

  • Shokrieh, Mahmood Mehrdad;Heidari-Rarani, Mohammad
    • Structural Engineering and Mechanics
    • /
    • v.37 no.2
    • /
    • pp.149-162
    • /
    • 2011
  • The aim of this research is a comprehensive review and evaluation of beam theories resting on elastic foundations that used to model mode-I delamination in multidirectional laminated composite by DCB specimen. A compliance based approach is used to calculate critical strain energy release rate (SERR). Two well-known beam theories, i.e. Euler-Bernoulli (EB) and Timoshenko beams (TB), on Winkler and Pasternak elastic foundations (WEF and PEF) are considered. In each case, a closed-form solution is presented for compliance versus crack length, effective material properties and geometrical dimensions. Effective flexural modulus ($E_{fx}$) and out-of-plane extensional stiffness ($E_z$) are used in all models instead of transversely isotropic assumption in composite laminates. Eventually, the analytical solutions are compared with experimental results available in the literature for unidirectional ($[0^{\circ}]_6$) and antisymmetric angle-ply ($[{\pm}30^{\circ}]_5$, and $[{\pm}45^{\circ}]_5$) lay-ups. TB on WEF is a simple model that predicts more accurate results for compliance and SERR in unidirectional laminates in comparison to other models. TB on PEF, in accordance with Williams (1989) assumptions, is too stiff for unidirectional DCB specimens, whereas in angle-ply DCB specimens it gives more reliable results. That it shows the effects of transverse shear deformation and root rotation on SERR value in composite DCB specimens.

Effects of Reticuloendothelial Hyperfunction on Preservation of Lung (망내계기능 항진이 폐장보존에 미치는 영향)

  • 박동식
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.145-152
    • /
    • 1974
  • The effect of reticuloendothelial hyperfunction on hypothermic preservation of lung was studied in dogs. In order to evaluate the viability after hemodynamic_ load in preserved isolated lung, observations were made on the rate of increase in weight, degree of edema,compliance and surface activity of lung. The results obtained as follows: l. In the group of activating of the reticuloendothelial system by injection of sodium thiosulfate intravenously before pneumonectomy and infusion of naphthionine through the pulmonary artery before hypothermic preservation of isolated lung the limit of preservation was eight hours whereas four hours in non-treated control group. 2.Therefore the method of activating of the reticuloendothelial system before and after pulmonary resection seems effective in preserving for prolonging the period of preservation of lung by means of inhibition of pulmonary edema. 3. Pulmonary surface activity is expected to be valuable as a method in evaluation of the viability of preserved lung along with compliance and rate of increase in weight of lung.

  • PDF

Motorcycle Inspection Standards Development I (이륜자동차 검사기준 개발 I)

  • Lim, Jaemoon;Ha, Taewoong;Hong, Seungjun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.4
    • /
    • pp.48-54
    • /
    • 2017
  • This paper presents the motorcycle inspection standards development on the vehicle identification, engine and transmission, tyres and wheels, steering and suspension, and brake system. 187 real-world motorcycles are visually and mechanically inspected according to the developed inspection standards. The non-compliance rate of the vehicle identification is 20.3% and main causes are insecure, damaged, and not clearly visible number plate. The non-compliance rate of the brake system is 15.5% and main cause is failing to meet the brake performance requirements. The motorcycle inspections standards are improved reflecting 187 cases of real-world motorcycle inspection results.