• 제목/요약/키워드: Compensation filter

검색결과 648건 처리시간 0.027초

새로운 직류 옵셋 제거 필터에 의한 정확한 페이저 추출에 관한 연구 (A Study on Accurate Phasor Extraction Using a New DC Offset Elimination Filter)

  • 박철원;윤희환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.29-36
    • /
    • 2013
  • In this paper, a new DC offset elimination filter is proposed for an accurate phasor extraction of fundamental frequency component. The proposed method can eliminate a DC offset component which is decayed exponentially. The proposed method uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. Also, the other advantages of the proposed method is that gain compensation or phase compensation is not required after filtering. Simulations using ATP were performed to evaluate the performance of the proposed filter method, and the results were compared to the ones obtained by conventional methods.

Intervening Firing Method and Passive Filter Design for Harmonic Elimination and Reactive Power Compensation in Three-Phase Thyristor Phase-Controlled Converters Supplying a DC Motor

  • Pattanapongchai, Artite;Wongtongdee, Surached W.;Laohasongkram, Piphat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.813-816
    • /
    • 2005
  • This paper presents a method for harmonic elimination and reactive power compensation using an intervening firing method and passive power filter with is suitable to compensate rapidly changing loads and reactive power. The proliferation of three-phase thyristor phase-controlled converter of DC motor drives into a power system has the potential to increase the harmonic levels in the power system. The design procedure of an intervening firing method and passive power filter capable of reducing the voltage and current harmonics produced by converter supplied from a source having internal large inductive impedance is offered. The analysis uses the or CAD PSpice to model three-phase thyristor phase-controlled converter of DC motor drives as well as the system.

  • PDF

Sliding Mode Control with Fixed Switching Frequency for Four-wire Shunt Active Filter

  • Hamoudi, Farid;Chaghi, A. Aziz;Amimeur, Hocine;Merabet, El Kheir
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.647-657
    • /
    • 2011
  • The present paper proposes a sliding mode control with fixed switching frequency for three-phase three-leg voltage source inverter based four-wire shunt active power filter. The aim is to improve phase current waveform, neutral current mitigation, and reactive power compensation in electric power distribution system. The performed sliding mode for active filter current control is formulated using elementary differential geometry. The discrete control vector is deduced from the sliding surface accessibility using the Lyapunov stability. The problem of the switching frequency is addressed by considering hysteresis comparators for the switched signals generation. Through this method, a variable hysteresis band has been established as a function of the sliding mode equivalent control and a predefined switching frequency in order to keep this band constant. The proposed control has been verified with computer simulation which showed satisfactory results.

전류 고조파와 불평형 전원 전압을 보상하는 직렬형 능동전력 필터와 병렬형 수동전력필터 병용시스템의 새로운 제어법 (A Novel Control Method of Combined System consists of Series Active Power Filter and Parallel Passive Power Filter to Compensate Current Harmonics and Unbalanced Source Voltages)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권12호
    • /
    • pp.615-623
    • /
    • 2001
  • In this paper, we study a series active power filter to compensate current harmonics and unbalanced source voltages. Conventional control methods for compensating unbalanced source voltages use source voltages to calculate compensation voltages, and in addition use load voltages to regulate load voltages. But the proposed control method uses load voltage to compensate unbalanced source voltages and regulate load voltages. And we propose a control method to reduce current harmonics which can calculate compensation voltages directly from source currents and load voltages. By well-matched operation of two control methods, the series active power filter can compensate current harmonics, unbalanced source voltages, and regulate load voltages. We compose a combined system of the series active power filter and parallel passive filters to confirm a validity of proposed control methods. The results from experiments are presented to demonstrate effectiveness of the proposed method.

  • PDF

Analysis and Specifications of Switching Frequency in Parallel Active Power Filters Regarding Compensation Characteristics

  • Guopeng, Zhao;Jinjun, Liu
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.749-761
    • /
    • 2010
  • The switching frequency of a power device is a very important parameter in the design of a parallel active power filter (PAPF), but so far, very little discussion has been conducted on it in a quantitative manner in previous publications. In this paper, an extensive analysis on the effects of the switching frequency on the performance of a PAPF is made, and a specification of the switching frequency values with different compensation results is presented. A first-order inertia element and a second-order oscillation element are considered as approximate models of a PAPF, respectively. The compensation characteristic for each order of harmonic current is obtained at different switching frequencies. Then, the THDs of each model for the system loads of a rectifier with resistance and inductance loads are proposed. The compensation results of a PAPF controlled as a first-order inertia element are better than those of a PAPF controlled as a second-order oscillation element. With two types of system loads which are rectifier with resistance and inductance loads and rectifier with resistance, inductance and capacitance loads, the THDs of the source current after compensation are presented with different switching frequencies. The compensation characteristics for the most widely used digital control system are investigated. The situation with an analog control is the theoretical characteristic and it is the best situation. The compensation characteristic of the digital control is worse than the compensation characteristic of the theoretical characteristic. Based on these analyses, the specifications of compensation characteristics with different switching frequencies are quite straightforward. Finally, a practical design example is studied to verify the application.

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF

3상 Z-소스 하이브리드 능동전력필터 시스템 (Three-Phase Z-Source Hybrid Active Power Filter System)

  • 임영철;김재현;정영국
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.75-85
    • /
    • 2010
  • 본 연구에서는 비선형 부하에서 발생되는 기본파 무효전력 및 고조파를 보상하기 위한 종전의 전압형 및 전류형 PWM 능동전력필터를 대체 할 수 있는 Z-소스 인버터 토폴로지의 하이브리드 능동전력필터에 대하여 고찰하였다. Z-소스 토폴로지의 능동전력필터의 보상 DC전원으로는 PEMFC가 사용되며, Z-소스 인버터의 shoot-through 듀티비의 조절에 의하여 낮은 연료전지의 전압을 높은 보상 전압으로 부스트 한다. 제안된 시스템은 병렬형 Z-소스 능동전력필터와 7차 고조파 (420Hz) 동조 필터로 구성되며, 이 구성에 의하여 Z-소스 능동전력필터의 스위치 디바이스의 전압 스트레스는 감소된다. 제안된 Z-소스 하이브리드 능동전력필터의 보상 알고리즘으로는 전류 동기 검출법이 사용되었다. 3상 220V/60Hz, 25A급 비선형 다이오드 부하 조건하에서 PSIM 시뮬레이션을 수행하였으며, 정상상태 및 과도상태에서의 제안된 시스템의 보상 성능을 파악하였다.

자동차 전동 시스템을 위한 Programmable 저역 통과 필터 기반의 상전류 극성 판단 및 데드타임 보상 (Dead Time Compensation and Polarity Check of Phase Currents Based on Programmable Low-pass Filter for Automotive Electric Drive Systems)

  • 최진철;이강석;이우택
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a dead time compensation method for an AC motor drive using phase current polarity information which is detected based on a digital programmable low-pass filter (PLPF). The polarity detection using the PLPF is an alternative solution of a conventional method which uses a general low-pass filter (LPF) and hysteresis bands in order to avoid jittering due to noises. The PLPF not only adjusts its cutoff frequency according to the synchronous frequency of AC motors but also eliminates a gain attenuation and phase delay which are main problems of the general LPF. Through the PLPF, a fundamental component signal without gain and phase distortions is extracted from the measured raw current signal with noise. By use of the fundamental component, the polarity of current is effectively detected by reducing the hysteresis band. Finally, the proposed method compensates the dead time effects by adding or subtracting average voltage value to voltage references of the controller according to the detected current polarity information. The proposed compensation method is experimentally verified by compared with the conventional method.

고차변조방식을 사용하는 광대역 시스템에서 평탄도(Ripple) 보상 필터 구현 (Implement a ripple Compensation filter in wideband system using high order modulation)

  • 윤병수;박창수;이덕환;김종현;이정용;진선후
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.470-473
    • /
    • 2018
  • 고차변조방식을 사용하는 광대역 시스템은 무선채널환경의 변화뿐만 아니라 baseband 신호가 RF 장비를 통과하면서 발생할 수 있는 평탄도(Ripple) 특성 변화에 민감하다. 따라서 평탄도 특성 변화를 최소화 할 수 있는 설계와 RF 튜닝이 필요하지만 시스템 구현이 어렵고 많은 시간이 소요된다. 본 논문에서는 baseband 신호가 RF 송수신 장비를 거치면서 왜곡되는 고정적인 평탄도 특성을 분석하여 보상 필터의 계수(Coefficient) 값을 추출하고 수신부에서 보상 필터로 보상을 하는 기능을 256TCM(Trellis Coded Modulation) 방식으로 구현하였다. 또한 시스템에 적용하여 시험한 결과 RF 송수신 장비의 평탄도 특성이 좋지 않은 주파수대역에서 디지털 보상필터를 적용하여 SNR 및 수신감도의 개선이 있음을 확인하였다.

  • PDF