• Title/Summary/Keyword: Comparison of efficiency

Search Result 3,222, Processing Time 0.036 seconds

Fabrication and Characterization of Miniaturized HTS Microstrip Antennas Using "H"-type Resonator (H 형태 공진기를 이용한 소형화된 HTS 안테나의 제작 및 특성 해석)

  • 정동철;윤창훈;황종선;최창주
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.7
    • /
    • pp.282-287
    • /
    • 2003
  • ″H″ type resonator has the advantage for the miniaturization of high-T7 superconducting (HTS) microstrip antenna in comparison with the conventional microstrip antenna such as rectangular type or circular type. In this paper we designed miniaturized HTS antennas using this "H"-type resonator and reported the characteristics of our antennas including return loss, bandwidth, radiation patterns, efficiency and so on. To fabricate the "H" type antenna, HTS YBa$_2$Cu$_3$$O_{7-x}$ (YBCO) thin films were deposited on MgO substrates using rf-magnetron sputtering. For comparison between normal conducting antennas and superconducting antennas, the gold antennas with the same dimension were also fabricated. An aperture coupling was used for impedance matching between 50 $\Omega$ feed line and HTS radiating patch. The ″H" type superconducting antenna showed the performance of 1.38 in SWR, 26 % in efficiency, and 13.8 dB in the return loss superior to the normal conducting counterpart.

Technical efficiency of the coastal composite fishery in Korea: a comparison of data envelopment analysis and stochastic frontier analysis

  • Kim, Do-Hoon;Seo, Ju-Nam;Lee, Sang-Go
    • The Journal of Fisheries Business Administration
    • /
    • v.41 no.3
    • /
    • pp.45-58
    • /
    • 2010
  • This study estimated the technical efficiency of coastal composite fishery in Korea by using the data envelopment analysis (DEA) and the stochastic frontier analysis (SFA) methods, and the results on the respective method were compared. In the DEA method, the constant returns to scale (CRS) and the variable returns to scale (VRS) output-oriented DEA models were separated and technical efficiencies were estimated, respectively. The average estimated value of technical efficiency by the SFA method (0.633) was found to be lower than that by the VRS-DEA method (0.738), while it was higher than that by the CRS-DEA method (0.479). It was found that strong correlation exists between the SFA method and the VRS-DEA method. The method which can utilize both methods in mutually complementing way for the estimation of technical efficiency was also considered.

An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window (고효율 로이유리 창호의 정량적 단열성능 평가)

  • Choi, Gyoung-Seok;Choi, Hyoun-Joung;Kang, Jae-Sik;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

Numerical comparison of bearing capacity of tapered pile groups using 3D FEM

  • Hataf, Nader;Shafaghat, Amin
    • Geomechanics and Engineering
    • /
    • v.9 no.5
    • /
    • pp.547-567
    • /
    • 2015
  • This study investigates the behavior of group of tapered and cylindrical piles. The bearing capacities of groups of tapered and cylindrical piles are computed and compared. Modeling of group of piles in this study is conducted in sand using three-dimensional finite element software. For this purpose, total bearing capacity of each group is firstly calculated using the load-displacement curve under specific load and common techniques. Then, the model of group of piles is reloaded under this calculated capacity to find group settlements, stress states on the lateral surfaces of group block, efficiency of group and etc. In order to calculate the efficiency of each group, single tapered and cylindrical piles are modeled separately. Comparison for both tapered and cylindrical group of piles with same volume is conducted and a relation to predict tapered pile group efficiency is developed. A parametric study is also performed by changing parameters such as tapered angle, angle of internal friction of sand, dilatancy angle of soil and coefficient of lateral earth pressure to find their influences on single pile and pile group behavior.

Development of 50W Solid Oxide Fuel Cell system (50W 고체 산화물 연료전지 시스템 구축)

  • Jee, Young-Seok;Lah, Se-Yun;Cho, Goo-Young;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.311-314
    • /
    • 2009
  • Recently by the development of the electronic engineering technology various mobile devices are developed. But their operation time need to be extended although capacity of the batteries are limited. We focused our attention to the portable SOFC system. Because SOFC has the high efficiency and a lot of strongness in comparison with other kinds of fuel cells, We evaluated hydrogen fed SOFC 50W system theoretically and got the results about the operating condition range from the comparison of the power efficiency, exhaust gas temperature, required heat for maintaining the operation temperature and operation time.

  • PDF

A Study A on Internal Loss Characteristics and Efficiency Improvement of Low Power Flyback Converter Using WBG Switch (WBG 스위치를 적용한 소용량 플라이백 컨버터의 내부손실 특성과 효율 개선에 관한 연구)

  • Ahn, Tae Young;Yoo, Jeong Sang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.99-104
    • /
    • 2020
  • In this paper, efficiency and loss characteristics of GaN FET were reported by applying it into the QR flyback converter. In particular, for the comparison of efficiency characteristics, QR flyback converter experimental circuits with Si FET and with GaN FET were separately produced in 12W class. As a result of the experiment, the experimental circuit of the QR flyback converter using GaN FET reached a high efficiency of 90% or more when the load power was 2W or more, and the maximum efficiency was observed to be about 92%, and the maximum loss power was about 1.1W. Meanwhile, the efficiency of the experimental circuit with Si FET increased as the input voltage increased, and the maximum efficiency was observed to be about 82% when the load power was 9W or higher, and the maximum loss power was about 2.8W. From the results, it is estimated that that in the case of the experimental circuit applying the GaN FET switch, the power conversion efficiency was improved as the switching loss and conduction loss due to on-resistance were reduced, and the internal loss due to the synchronous rectifier was minimized. Consequently, it is concluded that the GaN FET is suitable for under 20W class power supply unit as a high efficiency power switch.

Efficiency at Energy Industry : A Comparison of Energy Consumption Efficiency among Asian Pacific Countries

  • Kim, Tae-Ho
    • International Journal of Quality Innovation
    • /
    • v.9 no.3
    • /
    • pp.113-121
    • /
    • 2008
  • This paper proposes a scheme to estimate the technical efficiency of energy consumption and production and shadow prices of $CO_2$ emission in country-level at Asia Pacific countries by Data Envelopment Analysis (DEA). The result of technical efficiency estimation shows that there exists an heterogeneity and a substantial opportunity for improvement in technical efficiency at energy consumption and production across countries, specially in the $CO_2$ emission, which implies that more pollutant are spread in air. Each country will have the different willingness to pay for the additional $CO_2$ emission right and this result enables us to predict the competition in international $CO_2$ emission right market.

A Comparison Study of the Effect of Adding Ar or Kr Gas into the Conventional Gas Mixtures in a Matrix Type PDP

  • Khorami, Alireza;Ghanbari, Shirin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.748-751
    • /
    • 2009
  • This paper provides a novel scheme to enhance luminous efficiency within Plasma Display Panels (PDPs). The He-Xe or Ne-Xe mixtures are mainly used in conventional PDP cells, where their discharge characteristics exemplify different behavior. Significantly, the excitation efficiency in He-Xe is lower than that of the Ne-Xe mixture. This paper demonstrates that by adding a small quantity of Ar or Kr gas in Ne-Xe mixture increases cell efficiency, while for the He-Xe mixtures their cell efficiency is reduced.

  • PDF

Study on Applicability of Multi-Criteria Decision Making Technique for Malfunctioning Reservoir Selection (기능저하 저수지 선정을 위한 다기준 의사결정기법 적용성 연구)

  • Shim, Hyun Chul;Choi, Kyung Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.3
    • /
    • pp.11-19
    • /
    • 2017
  • The decision-making process is the act of finding the best solution among various alternatives through comparison between various criteria based on objectives of the project, evaluation standard, and conditions. However, in practice it is not easy to simply decide the optimum decision, especially for selecting malfunctioning reservoirs because no systematic evaluation criteria or standard assessment process are available. Therefore, this study adopted AHP method, which is a MCDM (multi-criteria decision making technique) to identify the malfunctioning reservoirs for efficient management of reservoirs. Important criteria of the selection of malfunctioning reservoirs and priority weights of each criteria were determined based on results of expert's survey under a stepwise hierarchical approach. The most important factor for the decision of malfunctioning reservoirs was obtained as Reservoir efficiency among the selected criteria including Reservoir efficiency decrease, Disaster Risk, Reservoir efficiency, Available water storage, Future water demand, Resident Needs. The AHP technique was applied on 11 reservoirs in Andong region to verify its applicability. Scoring method was applied for the comparison with the results of AHP method.

An Analysis of Comparison between the Evaluation Tool for Building Energy Efficiency Rating System and Detailed Analysis Programs (건물에너지효율등급 평가도구와 상세해석프로그램의 비교 분석)

  • Lee, Jae-Hyuk;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.3-8
    • /
    • 2009
  • Since 2001, the Building Energy Efficiency Rating and Certification System have been implemented in Korea. For rating the energy efficiency performance, the evaluation tool for Building Energy Efficiency Rating System has been used. In this study, the evaluation tool was compared with detailed analysis programs(Trnsys 16, ESP-r) through simulations of heating energy needs for apartment, and we checked the character of the evaluation tool.

  • PDF