• Title/Summary/Keyword: Communication architecture

Search Result 2,635, Processing Time 0.024 seconds

A Case Study on the Implementation of Integrated Operation System of the Nakdong River Estuary Barrage Due to the Drainage Gate Extension (낙동강 하굿둑의 배수문 증설에 따른 통합운영시스템의 구축 사례에 대한 연구)

  • Kim, Seokju;Lim, Taesoo;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.1
    • /
    • pp.183-199
    • /
    • 2015
  • Due to the Four Major Rivers Restoration Project, Nakdong River Estuary Barrage's designed flood quantity has been largely increased, and this has caused to construct several drainage gates at the right side of Eulsukdo island to secure the safety of downstream river area. For successful functioning of Nakdong River Estuary Barrage, such as flood control, disaster prevention, and the securing of sufficient water capacity, drainage gates at the both sides of island have to operate systematically and reliably. To manage this under restricted personnel and resources, we have implemented the IOS (Integrated Operation System) by integrating previous facilities and resources via information and communication technologies. The IOS has been designed to have higher availability and fault tolerance to function continuously even with the partial system's failure under the emergency situation like flood. Operators can use the system easily and acknowledge alarms of facilities through its IWS (Integrated Warning System) earlier. Preparing for Integrated Water Resources Management and Smart Water Grid, the architecture of IOS conformed to open system standards which will be helpful to link with the other systems easily.

MPI-OpenMP Hybrid Parallelization for Multibody Peridynamic Simulations (다물체 페리다이나믹 해석을 위한 MPI-OpenMP 혼합 병렬화)

  • Lee, Seungwoo;Ha, Youn Doh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.3
    • /
    • pp.171-178
    • /
    • 2020
  • In this study, we develop MPI-OpenMP hybrid parallelization for multibody peridynamic simulations. Peridynamics is suitable for analyzing complicated dynamic fractures and various discontinuities. However, compared with a conventional finite element method, nonlocal interactions in peridynamics cost more time and memory. In multibody peridynamic analysis, the costs increase due to the additional interactions that occur when computing the nonlocal contact and ghost interlayer models between adjacent bodies. The costs become excessive when further refinement and smaller time steps are required in cases of high-velocity impact fracturing or similar instances. Thus, high computational efficiency and performance can be achieved by parallelization and optimization of multibody peridynamic simulations. The analytical code is developed using an Intel Fortran MPI compiler and OpenMP in NURION of the KISTI HPC center and parallelized through MPI-OpenMP hybrid parallelization. Further parallelization is conducted by hybridizing with OpenMP threads in each MPI process. We also try to minimize communication operations by model-based decomposition of MPI processes. The numerical results for the impact fracturing of multiple bodies show that the computing performance improves significantly with MPI-OpenMP hybrid parallelization.

Evaluation of Capability for Practicing CM at Risk in Korea (국내 시공책임형 건설사업관리 수행을 위한 기업 역량 평가)

  • Ryu, HanGuk;Lee, Sangwon;Choi, Jaehyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2020
  • The Korean domestic construction management at risk (CMAR) market is in the process of completing the pilot project execution under the leadership of the Ministry of Land, Infrastructure and Transport as of December 2019. The government starts practicing CMAR an alternative delivery method widely in order to diversify delivery methods and enhance construction technology. The CMAR market is thus expected to grow. This study was conducted to improve CMAR firms' capability by developing self-assessment tools for them to evaluate current capability more effectively. As a result of defining standard core capability and additional elements categorized by project execution phase and management area, and performing evaluation from the CMAR project participants, it was found that the general project management capability in the pre-design and procurement phase and quality management area was lower compared to the construction phase and other areas. In addition, the capability of cost management area was lower in spite of its high importance. Communication and coordination, process optimization, and target values achievement were at the initial level of capability and continuous improvement was required.

An Analysis on Support Facilities Which Consider User's Characteristics in High-tech Industrial Estate in Urban Area (도시내 첨단 산업단지 이용자 특성을 고려한 지원시설 분석 연구)

  • Choi, Hyung-Ku;Kim, Won-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.291-299
    • /
    • 2016
  • Recently, the knowledge industry center has played a role as a facility that creates economic added value because of the high-tech companies related to the knowledge industry, information, and communication. On the other hand, support facilities that are provided in the knowledge industry center are meant to support the company in the center and improve the working conditions of laborers. On the other hand, the support policy established by the government applies to some companies, and none of the support policy is carried out in supporting facilities in the knowledge industry center. In this study, multiple analysis was performed, focusing on the support facilities in the knowledge industry center that aims to improve the working environment of laborers. This study suggests the introduction of guidelines to secure adequate area, depending on the type of supporting facilities in the Knowledge Industrial Center. The sharing of facilities, such as cultural and commercial use for Knowledge Industrial Center, corresponding to poor provision, is recommended. Because the analysis of IPA indicates that the area of commercial support facilities are higher than others and cultural facilities are more important and preferred, it is necessary to compose support facilities that consider the user's individual characteristics. Facilities impacting the working environment need to be planned carefully through a district unit plan at the initial stages of development, thus assisting the production activity of workers.

Dual-Band Six-Port Direct Conversion Receiver with I/Q Mismatch Calibration Scheme for Software Defined Radio (Software Defined Radio를 위한 I/Q 부정합 보정 기능을 갖는 이중 대역 Six-Port 직접변환 수신기)

  • Moon, Seong-Mo;Park, Dong-Hoon;Yu, Jong-Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.651-659
    • /
    • 2010
  • In this paper, a new six-port direct conversion receiver for high-speed multi-band multi-mode wireless communication system such as software defined radio(SDR) is proposed. The designed receiver is composed of two CMOS four-port BPSK receivers and a dual-band one-stage polyphase filter for quadrature LO signal generation. The four-port BPSK receiver, implemented in 0.18 ${\mu}m$ CMOS technology for the first time in microwave-band, is composed of two active combiners, an active balun, two power detector, and an analog decoder. The proposed polyphase filter adopt type-I architecture, one-stage for reduction of the local oscillator power loss, and LC resonance structure instead of using capacitor for dual-band operation. In order to extent the operation RF bandwidth of the proposed six-port receiver, we include I/Q phase and amplitude calibration scheme in the six-port junction and the power detector. The calibration range of the phase and amplitude mismatch in the proposed calibration scheme is 8 degree and 14 dB, respectively. The validity of the designed six-port receiver is successfully demonstrated by modulating M-QAM, and M-PSK signal with 40 Msps in the two-band of 900 MHz and 2.4 GHz.

An 1.2V 10b 500MS/s Single-Channel Folding CMOS ADC (1.2V 10b 500MS/s 단일채널 폴딩 CMOS A/D 변환기)

  • Moon, Jun-Ho;Park, Sung-Hyun;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.1
    • /
    • pp.14-21
    • /
    • 2011
  • A 10b 500MS/s $0.13{\mu}m$ CMOS ADC is proposed for 4G wireless communication systems such as a LTE-Advanced and SDR The ADC employs a calibration-free single-channel folding architecture for low power consumption and high speed conversion rate. In order to overcome the disadvantage of high folding rate, at the fine 7b ADC, a cascaded folding-interpolating technique is proposed. Further, a folding amplifier with the folded cascode output stage is also discussed in the block of folding bus, to improve the bandwidth limitation and voltage gain by parasitic capacitances. The chip has been fabricated with $0.13{\mu}m$ 1P6M CMOS technology, the effective chip area is $1.5mm^2$. The measured results of INL and DNL are within 2.95LSB and l.24LSB at 10b resolution, respectively. The SNDR is 54.8dB and SFDR is 63.4dBc when the input frequency is 9.27MHz at sampling frequency of 500MHz. The ADC consumes 150mW($300{\mu}W/MS/s$) including peripheral circuits at 500MS/s and 1.2V(1.5V) power supply.

Key Update Protocols in Hierarchical Sensor Networks (계층적 센서 네트워크에서 안전한 통신을 위한 키 갱신 프로토콜)

  • Lee, Joo-Young;Park, So-Young;Lee, Sang-Ho
    • The KIPS Transactions:PartC
    • /
    • v.13C no.5 s.108
    • /
    • pp.541-548
    • /
    • 2006
  • Sensor network is a network for realizing the ubiquitous computing circumstances, which aggregates data by means of observation or detection deployed at the inaccessible places with the capacities of sensing and communication. To realize this circumstance, data which sensor nodes gathered from sensor networks are delivered to users, in which it is required to encrypt the data for the guarantee of secure communications. Therefore, it is needed to design key management scheme for encoding appropriate to the sensor nodes which feature continual data transfer, limited capacity of computation and storage and battery usage. We propose a key management scheme which is appropriate to sensor networks organizing hierarchical architecture. Because sensor nodes send data to their parent node, we can reduce routing energy. We assume that sensor nodes have different security levels by their levels in hierarchy. Our key management scheme provides different key establishment protocols according to the security levels of the sensor nodes. We reduce the number of sensor nodes which share the same key for encryption so that we reduce the damage by key exposure. Also, we propose key update protocols which take different terms for each level to update established keys efficiently for secure data encoding.

Development of Family Nursing Phenomena in Korea by Retrospective Method of ICNP (ICNP의 후향적 개발방법에 의한 한국가족현상)

  • Yun, Sun-Nyeong;Kim, Hyeon-Suk;Gwon, Yeong-Suk;Park, Gyeong-Min;Kim, Hwa-Jung;Lee, Ji-Hyeon;Go, Yeong-Ae;So, Ae-Yeong;Yang, Sun-Ok;Jeon, Gyeong-Ja;Lee, In-Suk;Kim, Yeom-Im;Kim, Eun-Hui
    • Research in Community and Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.275-290
    • /
    • 1999
  • The Objectives of this study were to identify family nursing phenomena at the community in Korea and to contribute to build up family domain of International Classification for Nursing Practice. The method of this study was used retrospective one among three methods to develop ICNP during the period from April 1997 to June 1999. The procedure was to choose nursing phenomena using preliminary terms(stepl) from the reports on family nursing care of the nursing students of 5 junior colleges of nursing and 5 colleges of nursing. The study group members identified 3 common family nursing phenomena with 5 characteristics related to each phenomenon. In order to consensus the appropriate characteristics of a phenomenon(step2), 17 study group members had regrouped nursing phenomena and scored its characteristics 5 times. The essential characteristics of each family phenomenon were selected above 3.5 mean score from related characteristics(step 3). Finally, 17 phenomena were named preferred terms such as following, that was selected after investigated preliminary terms(step4). Family nursing phenomena in Korea are named as Lack of family interaction in community. Social isolation. Lack of social support system in community. Disturbance in parent role, Disturbance in marital role, Dissatisfaction of sexual life, Disturbance in family communication, Inappropriate family coping, Lack of family intimacy, Inappropriate family power structure, Family violence. Unhealthy life style. Deficit of financial management skill and support. Inadequate care a sick member. Insecure safety and hygiene in neighborhood, Inadequate home-sanitation. Inadequate home-making. Family nursing phenomena in Korea were partially confirmed family architecture of ICNP, Beta version. by this study. Further study on Family nursing phenomena in Korea will be required to support evidence through literature review of nursing classifications or field studies.

  • PDF

Performance Enhancement Method Through Science DMZ Data Transfer Node Tuning Parameters (Science DMZ 데이터 전송 노드 튜닝 요소를 통한 성능 향상 방안)

  • Park, Jong Seon;Park, Jin Hyung;Kim, Seung Hae;Noh, Min Ki
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.2
    • /
    • pp.33-40
    • /
    • 2018
  • In an environment with a large network bandwidth, maximizing bandwidth utilization is an important issue to increase transmission efficiency. End-to-end transfer efficiency is significantly influenced by factors such as network, data transfer nodes, and intranet network security policies. Science DMZ is an innovative network architecture that maximizes transfer performance through optimal solution of these complex components. Among these, the data transfer node is a key factor that greatly affects the transfer performance depending on storage, network interface, operating system, and transfer application tool. However, tuning parameters constituting a data transfer node must be performed to provide high transfer efficiency. In this paper, we propose a method to enhance performance through tuning parameters of 100Gbps data transfer node. With experiment result, we confirmed that the transmission efficiency can be improved greatly in 100Gbps network environment through the tuning of Jumbo frame and CPU governor. The network performance test through Iperf showed improvement of 300% compared to the default state and NVMe SSD showed 140% performance improvement compared to hard disk.

An Architecture for Managing Faulty Sensing Data on Low Cost Sensing Devices over Manufacturing Equipments (전문 설비의 이상신호 처리를 위한 저비용 관제 시스템 구축)

  • Chae, Yuna;Kim, Changi;Ko, Haram;Kim, Woongsup
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.3
    • /
    • pp.113-120
    • /
    • 2018
  • In this study, we proposed a monitoring system for identifying and handling faulty sensing stream data on manufacturing equipments where low-cost sensors can be safely used. Low cost sensors will lessen the cost of implementing distributed monitoring system, but suffer from sensor noises and inaccurate sensed data. Therefore, a distributed monitoring system with low cost sensors should identify faulty signal data as either of sensor fault or machine fault, and filter out faulty signals from sensing fault. To this end, we adopted a fourier transform based diagnostic approach mixed with a weighed moving averaging method, in order to identify faulty signals. We measured how effective our approach is and found out our approach can filter out one-third faulty signals from our experimental environment. In addition, we attached wireless communication modules to reduce sensor and network installation cost. To handle massive sensor data efficiently, we employed unstructured data format with NoSQL based database.