• Title/Summary/Keyword: Common-mode Current

Search Result 174, Processing Time 0.043 seconds

Suppression of high frequency leakage current in PWM Inverter-Fed Induction Motor Drives using Active Common Mode Voltage Damper (능동형 커먼 모드 전압 감쇄기를 통한 유도 전동기의 고주파 누설전류 억제)

  • 홍순일
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.186-190
    • /
    • 2000
  • This paper propose a "Active common-mode voltage damper circuit" that capable of a suppression of a common-mode voltage produced in the PWM VSI. The four level half-bridge PWM inverter circuit and common-mode transformer are incorporated into the "Active common-mode voltage damper" the design method of which is presented Effect of "Active common-mode voltage damper" in this paper verifies a propriety and effectiveness in 2.2[kW] induction motor drive using IGBT inverter. Experimental results show that "common-mode voltage damper" makes contributions to reducing a high frequency leakage current and common-mode voltage.leakage current and common-mode voltage.

  • PDF

The suppression of high frequency leakage current using a new active Common Mode Voltage Damper (새로운 능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제)

  • Gu Jeong-Hoi;Bin Jae-Goo;Park Sung-Jun;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.151-154
    • /
    • 2001
  • This paper propose a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI. The new active common mode voltage damper is consisted of a half-bridge inverter and a common mode transformer with a blocking capacitor. Principle of the active common mode damper is as follow; by applying the compensation voltage which has the same amplitude and opposite polarity to the PWM inverter system. So, common mode voltage and high frequency leakage current can be reduced. Simulated and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF

Reduction of common mode voltage and high frequency leakage current generated by the PWM voltage source inverter using common mode voltage damper (능동보조회로를 이용한 전압형 PWM 인버어터 시스템에서의 커먼 모드전압과 고주파 누설전류 억제방법에 관한 연구)

  • 전진휘;박성준;김광태;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.373-376
    • /
    • 1999
  • This paper propose a "common mode voltage damper" that is capable of reducing the common mode voltage produced in the PWM VSI. An push-pull circuits and high frequency leakage current damper[1] are incorporated into the "common mode voltage damper", the design method of which is presented. Effect of "common mode voltage damper" is simulated in this paper verifies the viability and effectiveness in 2.2kW induction motor drive using IGBT inverter. Simulated results show that "common mode voltage damper" makes significant contributions to reducing a high frequency leakage current.ducing a high frequency leakage current.

  • PDF

A Study on Reduction of Conducted-Noise by the Expanded Node of the Forward Converter (포워드 컨버터의 노드확장에 의한 전도성 노이즈 감소에 관한 연구)

  • Yi, Hee-Hoon;Kwon, Young-Ahn
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.374-379
    • /
    • 2006
  • The switch mode power supply is a source of EMI with other equipment as well as with its own proper operation because of rapid changes in voltages and currents within a switching converter. The EMI is transmitted in two forms: radiated and conducted. Conducted noise consists of two categories known as the differential mode and the common mode. Common mode noise current is a major source of EMI in the switch mode Power supply. Recently, a current balancing technique has been studied to reduce the common mode noise. This paper investigates the reduction of common mode noise according to a node expansion of the switch mode power supply which is based on a current balancing technique. In this paper, seven PCB patterns of the forward converter are manufactured and experimented.

Reducing Common-Mode Voltage of Three-Phase VSIs using the Predictive Current Control Method based on Reference Voltage

  • Mun, Sung-ki;Kwak, Sangshin
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.712-720
    • /
    • 2015
  • A model predictive current control (MPCC) method that does not employ a cost function is proposed. The MPCC method can decrease common-mode voltages in loads fed by three-phase voltage-source inverters. Only non-zero-voltage vectors are considered as finite control elements to regulate load currents and decrease common-mode voltages. Furthermore, the three-phase future reference voltage vector is calculated on the basis of an inverse dynamics model, and the location of the one-step future voltage vector is determined at every sampling period. Given this location, a non-zero optimal future voltage vector is directly determined without repeatedly calculating the cost values obtained by each voltage vector through a cost function. Without utilizing the zero-voltage vectors, the proposed MPCC method can restrict the common-mode voltage within ± Vdc/6, whereas the common-mode voltages of the conventional MPCC method vary within ± Vdc/2. The performance of the proposed method with the reduced common-mode voltage and no cost function is evaluated in terms of the total harmonic distortions and current errors of the load currents. Simulation and experimental results are presented to verify the effectiveness of the proposed method operated without a cost function, which can reduce the common-mode voltage.

A new active common mode voltage Damper to suppress high frequency leakage current of PWM Inverter (새로운 능동형 커먼 모드 전압 감쇄기를 이용한 PWM 인버터의 고주파 누설전류 억제)

  • 구정회;이상훈;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.423-431
    • /
    • 2001
  • This paper proposes a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI-fed induction motor drives. The new active common mode voltage damper is consists of a four-level half-bridge Inverter and a common mode transformer with a blocking capacitor. In order to reduce the common mode voltage and high frequency leakage current the active common mode damper applies to the PWM inverter system the compensated voltage of which the amplitude is the same as the common mode voltage and of which the polarity is opposite to the common mode voltage. Simulated using P-SPICE and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF

A Switching Method of Single Phase Grid Connected Inverter for Common Mode Noise Reduction (계통연계형 단상인버터의 Common Mode Noise 저감을 위한 Switching 방법)

  • Lee, Seung-Ju;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • A pulse-width modulation (PWM) method for common mode noise reduction in a PWM inverter connected to a single-phase grid is proposed in this study. The extensively used conventional switching method may experience common mode voltage problems, which generate current leakage and electromagnetic induction problems. In the proposed switching method, the neutral point of the output voltage is always fixed at both ends of the input voltage to reduce common mode noise. The validity of the proposed method is proven through simulation and experimental results.

A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제-)

  • 성병모;류도형;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • A PWM inverter for an induction motor often has a problem with a high frequency leakage current that flows through stray capacitors between stator windings and a motor frame to ground. This paper proposes a new type of Active Common Mode Voltage Canceler circuit for the reduction of common mode voltage and high frequency leakage current generated by the PWM VSI-fed induction motor drives. The compensating voltage applied by the common made voltage canceler has the same amplitude as, hut the opposite polarity to, the common mode voltage by PWM Inverter. Therefore, common mode voltage and high frequency leakage current can be canceled. The proposed circuit consists of four-level half-bridge inverter and common-mode transformer. Simulated and experimental results show that common mode voltage canceler makes significant contributions to reducing a high frequency leakage current.

  • PDF

Common-Mode Current Reduction with Synchronized PWM Strategy in Two-Inverter Air-Conditioning Systems

  • Baek, Youngjin;Park, Gwigeun;Park, Dongmin;Cha, Honnyong;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1582-1590
    • /
    • 2019
  • A new method for reducing the common-mode current generated by the voltage variations in a two-inverter air conditioner system by applying a synchronized pulse-width modulation (PWM) strategy is proposed. The PWM signals of the master-mode inverter are generated based on the reference voltage, while those of the slave-mode inverter are output in the opposite direction when the master-mode inverter changes its switching state. However, the slave-mode control results in a mismatch between the reference voltage and the actual output voltage that is modified by synchronized control operation. The proposed method is capable of reducing and controlling this voltage error by performing signal selection in the vector space of the slave-mode inverter, which mitigates the distortion of the phase current. The efficacy of this method in reducing conducted emissions has been validated both theoretically and experimentally.