• Title/Summary/Keyword: Common control point

Search Result 280, Processing Time 0.031 seconds

Development of a GPS Data Processing S/W for Cadastral Survey (지적측량을 위한 GPS 자료처리 S/W 개발)

  • 우인제;이종기;김병국
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.507-512
    • /
    • 2004
  • Research that establish new cadastral survey model that use GPS to introduce GPS observation technique in cadastral survey and research that develop connection technologies are gone abuzz. The purpose of this research is to keep in step in such trend and grasp present condition and performance of surveying connection to common use GPS data processing software, and analyze data processing algorithm, and develop suitable GPS data processing software in our real condition regarding GPS data processing and result of control point calculation. This research studies analysis common use software and error occurrence by data processing method that college and company have. Also, It analyzes algorithm that is applied to existing GPS data processing software. After that we study algorithm that is most suitable with cadastral survey and then develop cadastral survey calculation software for new cadastral control points

  • PDF

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

Effect of Wet-Cupping at Dachu(Dazhui)-point on Fever in Patients with Stroke (중풍환자의 발열에 대한 대추혈 사혈의 효과)

  • 손동혁;이영구;김영석;배형섭;이경섭;조기호
    • The Journal of Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.119-128
    • /
    • 2001
  • Objectives: Daechu (Dazhui: GV 14 (Governor Vessel))-point is located between the spinous process of the 7th cervical vertebra and that of the 1st thoracic vertebra. GV 14 has been used to treat high fever, neck pain, common cold, headache and so on. Fever may badly affect the improvement of stroke patients, so we investigated whether wet-cupping at GV 14 had effects on fever. Methods: In this study, 100 stroke patients were studied from Nov. 1999 to Oct. 2000. They were divided into the Sample group (n=49) and Control group (n=5l). The Sample group (n=49) was divided into Sample-Severe (n=2l), Sample-Mild (n=12), and Sample-Normal groups (n=16) and the Control group (n=5l) was divided into Control-Severe (n=8) and Control-Mild (n=43). We checked body temperature 6 times (just before treatment, after 30 ruin., 60, 90, 120 (2 hrs.), and 240 ruin. (4 hrs.)) in the Sample group and 3 times (just before treatment, after 120 min. (2 hrs.), and 240 ruin. (4 hrs.)) in the Control group. Results: In comparison with fever between before treatment and after 2 and 4 hours in each group, fever in the Sample subgroups decreased significantly in all cases, fever in the Control subgroups didn't decrease significantly in most cases except fever after 4 hours in the Control-Mild group. In comparison with fever differences between the Sample and Control group, fever of the Sample group more significantly decreased than that of the Control group in all comparisons. In comparison with fever among sample subgroups, fever of the Sample-Severe group decreased more than that of the Sample-Mild group but it was not significant. Conclusions: This study suggested that wet-cupping at GV 14 has significant effects on fever in stroke patients. We hope that this treatment will be used more widely as an emergent treatment.

  • PDF

The fast DCT algorithm based on the new prime factor and common factor decomposition

  • Choi, Byeong-Ho;Kim, Jong-Uk;Suh, Ki-Bum;Chong, Jong-Wha;Bang, Gyo-Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.245-250
    • /
    • 1992
  • In this paper, we present a nev algorithm for the fast computation of the discrete cosine transform(DCT). This algorithm consists of the three dimensional prime factor-decomposed algorithm(PFA) and three dimensional common factor-decomposed algorithm(CFA). We can compute N-point DCT for the number N decomposable Into three relative prime numbers using PFA and into three common numbers using CFA. We also show input and output index mapping for the three decomposition. it results in requiring fever multiplicaions than the previous algorithms. Particularly, for the large number N, it is more powerful in reducing the number of multiplication.

  • PDF

A Robust Design of Automatic Transfer Line System using Taguchi's Method (다구치 방법에 의한 자동흐름라인 시스템의 안정설계)

  • 김홍준;양정문;송서일
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.36
    • /
    • pp.297-306
    • /
    • 1995
  • An automatic transfer line consists of several stages(groups of stations) in series into one system by a common transfer mechanism and a common control system. In this system losses of the efficiency are evidenced in periods where a stage is forcod down- starved or blocked. The efficiency of an automatic transfer line can be improved by providing buffer storages between a stage or the length of line common senses there are several critical factors, system configurations relative position, and buffer capacity allocations in automatic transfer line are considered with a point of view production rates, average stock, and mean delay. The propose of this paper is to provide the robust designs by Taguchi method which improve the efficiency of four-stage transfer line.

  • PDF

Sensorless Control Method of the BLDC Motor Without Neutral Point (중성점을 사용하지 않는 BLDC 전동기 센서리스 제어 기법)

  • Sim, Kwang-Ryeol;An, Jeong-Ryeol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.3
    • /
    • pp.111-115
    • /
    • 2012
  • Generally, brushless DC motor(BLDCM) driving system uses hall sensors or encoders as the mechanical position or speed sensor. It is necessary to achieve the informations of rotor position for driving trapezoidal type brushless DC motor without any position sensor. In this paper, the commutation signals are obtained without the motor neutral voltage, multistage analog filters, A/D converters, or the complex digital phase shift circuits which are indispensable in the conventional sensorless control algorithms. In the proposed method, in stead of detecting the zero crossing point of the nonexcited motor back electromagnetic force for the average motor terminal to neutral voltage, the commutation signal are extracted directly from the specific average line to line voltage with low-pass filter, adder and comparators circuit. In contrast to conventional methods, the neutral voltage is not need; therefore, the commutation signals are insensitive to the common mode noise. Moreover, the complex phase shift circuit can be eliminated. The effectiveness of the proposed method is verified through simulation results.

Modeling of blend surfaces by Non Uniform B-spline surface patches (Non Uniform B-spline(NUB) 곡면에 의한 블랜드 곡면의 모델링)

  • Yoo, Woo-Sik;Jeong, Hoi-Min
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.95-100
    • /
    • 2000
  • Presented in this paper is a scheme for constructing ball rolling blends of a non-uniform B-spline surface(NUBS) patches. Ball rolling blending is a popular technique for blending between parametric surfaces. Along the "common edge" of a pair of "base surfaces" to be blended, a sequence of "ball positions" is sampled. The radius of the ball may vary along the line. At each sampling point, a ball center point and a pair of ball contact points are computed by applying a Jacobian inversion method. Using ball contact points, the constructing scheme of blend NUBS patches consists three steps; 1) determination of intermediate control vertices; 2) determination of boundary vectors; 3) determination of B-spline control vertices. The proposed blending scheme has been tested in a Omega CAM system and found to be working satisfactorily.

  • PDF

An Enhanced PCC Harmonic Voltage Mitigation and Reactive Power Sharing in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.138-140
    • /
    • 2018
  • Parallel distributed generators (DGs) in the islanded microgrid are generally operated autonomously by means of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accuracy of reactive power sharing. Moreover, the uncontrolled harmonic power reduces the point of common coupling (PCC) voltage quality and microgrid stability. In order to solve these problems, this paper proposes an enhanced PCC harmonic control strategy and an improved reactive power sharing control scheme. Based on the low bandwidth communications, a secondary control is implemented with both central controller and local controller. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

Enhanced Reactive Power Sharing and Voltage Restoration in Islanded Microgrid

  • Pham, Minh-Duc;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.47-48
    • /
    • 2016
  • Parallel distributed generators (DGs) in the islanded micro-grid are normally controlled with the aid of the droop control scheme. However, the traditional droop control methods which use the P-${\omega}$ and Q-E curve to share power between DGs are still concerned to improve the accurate of reactive power sharing and variation of frequency and voltage at the point of common coupling (PCC). This paper proposes a control scheme to solve the limitation of microgrid in islanded operation such as reactive power sharing accuracy and PCC voltage and frequency restoring. In order to achieve the control objective, a secondary control is implemented with both central controller and local controller by using the low bandwidth communications. The effectiveness of the proposed control scheme is analyzed through the simulation.

  • PDF

Adaline-Based Control of Capacitor Supported DVR for Distribution System

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.386-395
    • /
    • 2009
  • In this paper, a new control algorithm for the dynamic voltage restorer (DVR) is proposed to regulate the load terminal voltage during various power quality problems that include sag, swell, harmonics and unbalance in the voltage at the point of common coupling (PCC). The proposed control strategy is an Adaline (Adaptive linear element) Artificial Neural Network (ANN) and is used to control a capacitor supported DVR for power quality improvement. A capacitor supported DVR does not need any active power during steady state because the voltage injected is in quadrature with the feeder current. The control of the DVR is implemented through derived reference load terminal voltages. The proposed control strategy is validated through extensive simulation studies using the MATLAB software with its Simulink and SimPower System (SPS) toolboxes. The DVR is found suitable to support its dc bus voltage through the control under various disturbances.