• Title/Summary/Keyword: Comminuted fracture

Search Result 122, Processing Time 0.032 seconds

The Treatment of Tibial Shaft Fractures by Interlocking Nailing (Interlocking Nail을 사용한 경골간부 골절의 치료)

  • Lee, Jae-Chang;Lee, Jae-Sung;Ahn, Myun-Whan;Kim, Sae-Dong;Ihn, Joo-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.61-67
    • /
    • 1988
  • The treatment of tibial shaft fracture has become one of the most controversial subjects in orthopedic surgery. Comminuted, segmental and rotationally unstable fractures or bone defect at fracture site have problems of the fixation. The interlocking nail solve these problems. We have experienced 8 cases of the tibial shaft fractures treated with interlocking nail from 1986 to 1988. Authors analysed these cases and our own clinical study. The results were as follows. 1. The average bone union rate was about 15 weeks. 2. The interval between operation and crutch walking was 4:3 weeks. 3. The merits of this operation were the short hospitalization and early adaptation of social activity. 4. The advantage is be able to do early ambulation without following muscular atrophy or joint stiffness. 5. The results were assessed on clinical examination and radiographic appearance by Hamza et al. An excellent results were 7 cases and good result was 1 case.

  • PDF

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Result of Staged Operation in Ruedi-Allgower Type II and III Open Tibia Pilon Fractures with Severe Comminution (분쇄가 심한 Ruedi-Allgower II, III형의 개방성 경골 천정 골절에서 단계적 수술의 결과)

  • Choi, Kwi Youn;Lee, Jun Young;Jang, Hyunwoong;Kim, Young Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.110-115
    • /
    • 2019
  • Purpose: This study analyzed the clinical and radiological results of Reudi-Allgower type II and III open tibia pilon fracture patients who underwent plate fixation after the recovery of a soft tissue injury after external fixation. Materials and Methods: From 2010 to 2015, this study analyzed 14 patients who were treated for open tibial pilon fractures and could be followed up at least one year. The mean age was 49 years and the average follow-up period was 19 months. An emergency operation was performed for external fixation and open wounds, and secondary surgery was performed for definitive fixation using a plate. The radiological and clinical evaluations were analyzed retrospectively. Complications, such as post-traumatic osteoarthritis and wound infections were also analyzed. Results: The mean duration between two-staged surgery was 21 days and the mean bone union time was 9.2 months. Three cases of delayed union and one case of nonunion were reported. The malunion did not occur in all cases. The average American Orthopaedic Foot and Ankle Society (AOFAS) score was 68 points. A limitation of the ankle motion occurred in all cases. In four cases, wound infections due to initial open wounds occurred; one patient underwent a below the knee amputation due to chronic osteomyelitis. Post-traumatic arthritis occurred in 10 cases. Conclusion: Severe comminuted tibial plateau open fractures of Reudi-Allgower type II and III, which are high-energy injuries that result in extensive soft tissue damage, have a higher incidence of complications, such as ulcer problems and osteomyelitis, than closed tibia plateau fractures. Post-traumatic arthritis is the most common complication of tibia plateau open fractures, and staged surgery is recommended because of the relatively satisfactory clinical results.

The Usefulness of the Endonasal Incisional Approach for the Treatment of Nasal Bone Fracture

  • Kim, Hyo-Seong;Suh, Hyeun-Woo;Ha, Ki-Young;Kim, Boo-Yeong;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.209-215
    • /
    • 2012
  • Background : Among all facial fractures, nasal bone fractures are the most common, and they have been reduced by closed reduction (CR) for a long time. But several authors have reported suboptimal results when using CR, and the best method of nasal bone reduction is still being debated. We have found that indirect open reduction (IOR) through an endonasal incisional approach is a useful method for more accurate reduction of the nasal bone. Methods : A retrospective chart review was performed of 356 patients who underwent reduction of a nasal bone fracture in our department from January, 2006, to July, 2011. We treated 263 patients with IOR. We assessed patients' and doctors' satisfaction with surgical outcomes after IOR or CR. We evaluated the frequency of nasal bleeding owing to mucosal injury, and followed the surgical outcomes of patients who had simultaneous dorsal augmentation rhinoplasty. Results : According to the analysis of the satisfaction scores, both patients and doctors were significantly more satisfied in the IOR group than the CR group (P<0.05). Mucosal injury with nasal bleeding occurred much less in the IOR group (5.3%) than the CR group (12.9%). Dorsal augmentation rhinoplasty with IOR was performed simultaneously in 34 cases. Most of them (31/34) showed satisfaction with the outcomes. Conclusions : IOR enables surgeons to manipulate the bony fragment directly through the endonasal incisional approach. However, we propose that CR is the proper technique for patients under 16 and for those with comminuted nasal bone fractures because submucosal dissection in IOR can damage the growth or circulation of nasal bone.

Reduction of comminuted fractures of the anterior wall of the frontal sinus using threaded Kirschner wires and a small eyebrow incision

  • Lee, Da Woon;Kwak, Si Hyun;Choi, Hwan Jun;Kim, Jun Hyuk
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.220-227
    • /
    • 2022
  • Background: Frontal sinus fractures are relatively rare. Their surgical management significantly differs depending on whether the posterior wall is invaded and the clinical features vary. A bicoronal incision or endoscopic approach can be used. However, the minimally invasive approach has been attracting attention, leading us to introduce a simple and effective surgical method using multiple-threaded Kirschner wires. Methods: All patients had isolated anterior wall fractures without nasofrontal duct impairment. The depth from the skin to the posterior wall was measured using computed tomography to prevent injury. The edge of the bone segment on the skin was marked, a threaded Kirschner wire was inserted into the center of the bone segment, and multiple Kirschner wires were gently reduced simultaneously. Results: Surgery was performed on 11 patients. Among them, seven patients required additional support for appropriate fracture reduction. Therefore, a periosteal elevator was used as an adjunct through a small sub-brow incision because the reduction was incomplete with the Kirschner wire alone. The reduction results were confirmed using facial bone computed tomography 1 to 3 days postoperatively. The follow-up period was 3 to 12 months. Conclusion: The patients had no complications and were satisfied with the surgical results. Here we demonstrated an easy and successful procedure to reduce a pure anterior wall frontal sinus fracture via non-invasive threaded Kirschner wire reduction.

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Experiences of Emergency Surgical Treatment for a COVID-19 Patient with Severe Traumatic Brain Injury at a Regional Trauma Center: A Case Report

  • Yun, Jung-Ho
    • Journal of Trauma and Injury
    • /
    • v.34 no.3
    • /
    • pp.212-217
    • /
    • 2021
  • Various medical scenarios have arisen with the prolonged coronavirus disease 2019 (COVID-19) pandemic. In particular, the increasing number of asymptomatic COVID-19 patients has prompted reports of emergency surgical experiences with these patients at regional trauma centers. In this report, we describe an example. A 25-year-old male was admitted to the emergency room after a traffic accident. The patient presented with stuporous mentality, and his vital signs were in the normal range. Lacerations were observed in the left eyebrow area and preauricular area, with hemotympanum in the right ear. Brain computed tomography showed a contusional hemorrhage in the right frontal area and an epidural hematoma in the right temporal area with a compound, comminuted fracture and depressed skull bone. Surgical treatment was planned, and the patient was intubated to prepare for surgery. A blood transfusion was prepared, and a central venous catheter was secured. The initial COVID-19 test administered upon presentation to the emergency room had a positive result, and a confirmatory polymerase chain reaction (PCR) test was administered. The PCR test confirmed a positive result. Emergency surgical treatment was performed because the patient's consciousness gradually deteriorated. The risk of infection was high due to the open and unclean wounds in the skull and brain. We prepared and divided the COVID-19 surgical team, including the patient's transportation team, anesthesia team, and surgical preparation team, for successful surgery without any transmission or morbidity. The patient recovered consciousness after the operation, received close monitoring, and did not show any deterioration due to COVID-19.

Treatment of Blow-out Fractures Using Both Titanium Mesh Plate and Porous Polyethylene (Medpor®) (광범위한 안와파열골절에서 Titanium Mesh Plate와 Porous Polyethylene (Medpor®) 동시 사용의 유용성)

  • Gu, Ja Hea;Won, Chang Hoon;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • Purpose: The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years, a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However, in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and $Medpor^{(R)}$. Methods: Eighty six patients with extensive orbital fractures, who were admitted between March 1999 and February 2007, were reviewed retrospectively. The patients' chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and $Medpor^{(R)}$ (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. $Medpor^{(R)}$ was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos, diplopia, sensory disturbances and eyeball movement for a period of at least 6 months. Results: No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures. Conclusion: The use of both a titanium mesh plate and $Medpor^{(R)}$ simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures.

The Analysis of Conservative Treatment in Midshaft Fractures of Clavicle (쇄골 간부 골절의 보존적 치료 분석)

  • Cha, Seung-Do;Chung, Soo-Tai;Kim, Yong-Hoon;Park, Sang-Jun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Purpose: Most clavicular fractures can be healed by conservative treatment, although there are many factors that influence healing. The aim of the present study was to analyze factors that influence (i) bone union of midshaft fractures of the clavicle treated conservatively and (ii) bone functioning, after union. The long-term goal was to determine which treatments are adequate. Materials and Methods: We evaluated factors that have an effect on bone union and bone function after union. We evaluated age, fracture site, comminution, displacement, shortening and other factors. Among 523 clavicular midshaft fractures that presented between January 2004 and Jun 2009 at our Department of Orthopaedic Surgery, we identified 270 who had conservative treatment and 173 patients who had surgical treatment. Results: The period required for bone union increased with the degree of displacement. For the group below 12 years of age, and the group without comminution, it took half the time to achieve bone union compared with the other groups. Displacement mostly occurred within 2 weeks after conservative treatment. Conclusion: In patients with a comminuted clavicular midshaft fracture, we might, because of expected delays in bone union, delay the start of rehabilitation until patients are more than 13 years old. Because the degree of displacement may be increased within 2 weeks during conservative treatment, we can think about surgical treatments.

THE LONG-TERM CONSERVATIVE DRAINAGE CARE OF EXTENSIVE OSTEOMYELITIS ASSOCIATED WITH MANDIBULAR COMPOUND FRACTURE : REPORT OF A CASE (장기간의 보존적 배농술로 치료된 하악 복합골절 관련 광범위 골수염 치험 : 증례보고)

  • Kim, Ha-Rang;Yoo, Jae-Ha;Choi, Byung-Ho;Sul, Sung-Han;Mo, Dong-Yub;Lee, Chun-Ui
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.544-549
    • /
    • 2009
  • Failure to use effective methods of reduction, fixation and immobilization may lead to osteomyelitis with the exposed necrotic bone, as the overzealous use of transosseous wires & plates that devascularizes bone segments in the compound comminuted fractures of mandible. Once osteomyelitis secondary to fractures has become established, intermaxillary fixation should be instituted as early as possible. Fixation enhances patient comfort and hinders ingress of microorganisms and debris by movement of bone fragments. Teeth and foreign materials that are in the line of fracture should be removed and initial debridement performed at the earliest possible time. Grossly necrotic bone should be excised as early as possible ; no attempt should be made to create soft tissue flaps to achieve closure over exposed bone. The key to treatment of chronic osteomyelitis of the mandible is adequate and prolonged soft tissue drainage. If good soft tissue drainage is provided over a long period, sequestration of infected bone followed by regeneration or fibrous tissue replacement will occur so that appearance and function are not seriously altered. Localization and sequestration of infected mandible are far better performed by natural mechanism of homeostasis than by cutting across involved bone with a cosmetic or functional defect. As natural host defenses and conservative therapy begin to be effective, the process may become chronic, inflammation regresses, granulation tissue is formed, and new blood vessels cause lysis of bone, thus separating fragments of necrotic bone(sequestra) from viable bone. The sequestra may be isolated by a bed of granulation tissue, encased in a sheath of new bone(involucrum), and removed easily with pincettes. This is a case report of the long-term conservative drainage care in osteomyelitis associated with mandibular fractures.