• Title/Summary/Keyword: Comminuted

Search Result 166, Processing Time 0.033 seconds

Product Characteristics of Comminuted Sausages as Affected by Various Fat and Moisture Combinations

  • Chin, Koo Bok;Lee, Hye Lan;Chun, Soon Sil
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.4
    • /
    • pp.538-542
    • /
    • 2004
  • Comminuted sausages with reduced fat (25-0%) and increased moisture (19-44%) combinations were manufactured, and their chemical composition, and physico-chemical, textural and sensory properties were determined for the selection of the most palatable sausage treatment. The moisture and fat contents of the comminuted sausages varied from 55-79% and 26.4-2.14%, respectively, whereas, the protein content was relatively constant at 13.5-14.5%. Expressible moisture (EM, %) decreased with increased fat addition, and the high-fat control sausage (~25% fat) had lower EM than those with lower than 15% fat addition. Increased fat level also increased Hunter L values (lightness) of sausage samples taken from the core, and differences in lightness were observed between 15 and 25% fat level at the initial mixture. Sausages without fat addition had different textural characteristics from high-fat control sausages in most texture profile analysis (TPA) values. However, no differences in TPA values were observed among treatments with added fat (<25%) in the formulation. Results of the sensory evaluation showed that the most appropriate fat content of comminuted sausages to have better sensory properties ranged from 15-20% of added fat at the initial mixture. These results also indicated that decreased fat and increased moisture contents produce sausages with higher EM and lower lightness. Comminuted sausages without fat addition had different textural characteristics from the high-fat control.

Combined Orbital Fractures: Surgical Strategy of Sequential Repair

  • Hur, Su Won;Kim, Sung Eun;Chung, Kyu Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2015
  • Background Reconstruction of combined orbital floor and medial wall fractures with a comminuted inferomedial strut (IMS) is challenging and requires careful practice. We present our surgical strategy and postoperative outcomes. Methods We divided 74 patients who underwent the reconstruction of the orbital floor and medial wall concomitantly into a comminuted IMS group (41 patients) and non-comminuted IMS group (33 patients). In the comminuted IMS group, we first reconstructed the floor stably and then the medial wall by using separate implant pieces. In the non-comminuted IMS group, we reconstructed the floor and the medial wall with a single large implant. Results In the follow-up of 6 to 65 months, most patients with diplopia improved in the first-week except one, who eventually improved at 1 year. All patients with an EOM limitation improved during the first month of follow-up. Enophthalmos (displacement, 2 mm) was observed in two patients. The orbit volume measured on the CT scans was statistically significantly restored in both groups. No complications related to the surgery were observed. Conclusions We recommend the reconstruction of orbit walls in the comminuted IMS group by using the following surgical strategy: usage of multiple pieces of rigid implants instead of one large implant, sequential repair first of the floor and then of the medial wall, and a focus on the reconstruction of key areas. Our strategy of step-by-step reconstruction has the benefits of easy repair, less surgical trauma, and minimal stress to the surgeon.

TREATMENT OF COMPOUND COMMINUTED MANDIBULAR FRACTURES (하악골 복합 분쇄 골절의 치험례)

  • Jeong, Jong-Cheol;Kim, Keon-Jung;Choi, Jae-Sun;Sung, Dae-Kyung;Kim, Ho-Sung;Lee, Gye-Hyeok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.101-105
    • /
    • 1998
  • Compound comminuted mandibular fracture is defined as the presence of multiple fracture lines with open wound resulting in many small pieces within the same area. The incidence of mandibular comminution is difficult to determine but reported as 2.7~18.6 % incidence among mandibular fractures. There are controversies in the treatment of mandibular comminuted fractures. Treatment of comminuted mandibular fracture has traditionally involved closed reduction in an effort to avoid stripping periostcum from the bony segments, but rigid internal rigid fixation is used more popular at present. The extent of comminution, displacement of bony fragments and patient general conditions are important factors in decision of the treatment methods. When significant bone displacement is present, it is necessary to reduce these comminuted fragments to an anatomic, pretraumatic relationship to restore facial form and function. In these cases, ORIF allows anantomic reduction of comminuted segments as well as pretraumatic occlusion. Gentle handling of the soft tissue, rigid fixation of bony fragments and adequate immobilization are essential for reducing the complications. This is the report the incidence, causes, complications and treatment of the patients who visited our department for compound comminuted mandibular fractures.

  • PDF

A study on the Porosity Characterization of U$_3$Si$_2$ Dispersion Fuel prepared with Atomized and Comminuted Powders

  • Kim, Chang-Kyu;Ko, Young-Mo;Cho, Hae-Dong;Lee, Don-Bae;Kim, Ki-Hwan;Lee, Chong-Tak;Kuk, Il-Hiun;G. L. Hofman
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.623-629
    • /
    • 1995
  • To investigate the effects of powder shape on U loading density of fuel meat, two kinds of fuel meats were prepared with atomized and comminuted U$_3$Si$_2$ powders by extrusion or rolling process. Extruded fuel meats with atomized spherical U$_3$Si$_2$ powder appeared to have much less porosity than those with comminuted irregular U$_3$Si$_2$ powder at higher U$_3$Si$_2$ fraction- The U$_3$Si$_2$ particles with spherical shape are less fractured in extrusion than in rolling. Most of atomized particles on the whole maintained to have spherical shapes in the extrusion. It has been shown that atomized spherical particles are expected to approach similar upper loading limits comparing with comminuted particles in rolled plates, but exceed comminuted powder loading limits in extruded rods.

  • PDF

TREATMENTS OF COMMINUTED MANDIBULAR FRACTURES (하악골 분쇄골절의 치료)

  • Jeon, Woo-Jin;Kim, Su-Gwan;Kim, Hyeon-Ho;Kim, Hak-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.71-75
    • /
    • 2005
  • This study evaluated retrospectively the treatment method and postoperative complications of communited mandibular fractures. We analyzed the clinical and radiologic data of 14 patients with the comminuted mandibular fractures who were admitted to Chosun University Dental Hospital from January 1998 to December 2003. We reviewed the cause of trauma, fracture sites, treatment methods, and postoperative complications. Thirteen patients (93%) had a successful treatment outcome without complications. Only one patient developed postoperative osteomyelitis requiring early plate removal and sequestrectomy. For the comminuted fractures of mandible, internal fixation using micro- or mini-plate was an effective treatment method with a low incidence of major complications.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

Transosseous Tie Fixation Using Krackow Sutures and Bone Tunnels in a Comminuted Fracture of the Upper Pole of the Patella: A Case Report

  • Baik, Jong Seok
    • Journal of Trauma and Injury
    • /
    • v.34 no.4
    • /
    • pp.305-308
    • /
    • 2021
  • Comminuted fractures of the patella mostly occur at the inferior pole and require appropriate reduction and fixation to restore the extensor mechanism. Conventional methods such as tension-band wiring are not enough to gain proper fixation strength. Numerous methods have been reported, including circumferential cerclage wiring, osteosynthesis, and suture anchors depending on the fracture pattern. Herein, the author reports a relatively rare case of a comminuted fracture of the upper pole of the patella, for which we used augmented Krackow sutures in the quadriceps and fixation with tying of the suture limbs through patellar bone tunnels. Satisfactory results were obtained in terms of reduction and extensor mechanism recovery.

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk;Chang, Suk Choo;Shin, Jin Yong;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.175-180
    • /
    • 2018
  • Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Guided Bone Regeneration in Comminuted Long-Bone Fractures Using Recombinant Human Bone Morphogenetic Protein-2 and a Collagen Membrane

  • Jang, Kwangsik;Jo, Hyun Min;Shim, Kyung Mi;Kim, Se Eun;Kang, Seong Soo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.59-64
    • /
    • 2022
  • A dog aged two years and seven months and a cat aged seven years were referred owing to fractures of long bones. Preoperative radiographs revealed comminuted bone fractures close to joints. Conventionally, long-bone fractures are treated using intramedullary pins, plate and screw systems, or an external fixator system. In cases of non-reducible fractures, various graft materials have been used in fracture treatments to stimulate bone repair. Here, recombinant human bone morphogenetic protein-2 (rhBMP-2) and a collagen membrane were applied. Four weeks after surgery, fractured bone fragments began to unite and the bone union was observed using radiography four months after surgery. No complications occurred related to grafted materials. We successfully applied rhBMP-2 and collagen membranes in two different species to support the healing process of comminuted fractures, according to the concept of guided bone regeneration.